background image

manuals-backend.z-wave.info/make.php?lang=en&sku=AEOEZWA005&cert=ZC10-18046087&type=mini

1/7

Aeotec

TriSensor

SKU: AEOEZWA005

ZWave+

 

 

Quickstart

This is a 

secure Notification Sensor

 for 

XXXQFrequencyName

. To run this device please insert fresh 

1 * CR123A

 batteries. To run this device please

make sure the internal battery is fully charged. Press once TriSensors Action Button. If it is the first installation, the yellow LED will keep solid until whole
network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for
30 seconds, then the green LED flashes once.If it is the S2 encryption network, please enter the first 5 digits of DSK.

 
 

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer,
importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other
material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or
near open heat sources. 

Product Description

TriSensor can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All
non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. If PIR motion sensor is
triggered, the TriSensor will send a Basic set to associated devices.The PIR motion sensor will then become inactive. If no PIR motion is triggered after the
PIR interval time (configurable), the TriSensor will send Basic Set to the associated nodes.

Installation

With your TriSensor now a part of your Z-Wave network and having determined its installation location, it s time to finish its
physical installation. There are 2 ways that your TriSensor can be mounted on a wall or ceiling. Most simply it can be placed upon
a shelf without the need to attach further accessories. You can mount your sensor in a corner or against a wall or ceiling by using
the Back-Mount Plate. It s also possible to embed your TriSensor within a ceiling or wall using its Recessor accessory (sold
separately).

 

 

To install your TriSensor:

Reattach the three parts of your TriSensor to each other. Unlock the Battery Cover from the Sensor unit.

 

You may also install your TriSensor on any flat surface area such as tables, and bookshelves;

 

You can place it upon a shelf without the need to attach further accessories.

To install your TriSensor with the Back-Mount Plate;

Summary of Contents for TriSensor AEOEZWA005

Page 1: ...ion TriSensor can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated nodes within the networ...

Page 2: ...there are some things you should first consider TriSensors motion sensor uses light and heat readings to determine motion sudden light and heating changes can impact the sensor s quality of motion rea...

Page 3: ...battery compartment 2 Press the button once Exclusion 1 Open the battery compartment 2 Press the button once NIF XXXNIF Wakeup Press and hold the button at least 2s until Red Led is on and then relea...

Page 4: ...SIC_SET 0xFF to devices associated in group 2 when motion event is cleared 2 Send BASIC_SET 0xFF to devices associated in Group 2 when motion event is triggered 3 Send BASIC_SET 0x00 to devices associ...

Page 5: ...ption 0 Disable 1 Red 2 Green 3 Blue 4 Yellow 5 Pink 6 Cyan 7 Purple 8 Orange Parameter 13 Led Color For Light Sensor Report Size 1 Byte Default Value 0 Setting Description 0 Disable 1 Red 2 Green 3 B...

Page 6: ...for change in light sensor to induce an automatic report for temperature sensor Size 2 Byte Default Value 100 Setting Description 0 10000 Lux Parameter 23 Temperature Sensor ReportInterval This param...

Page 7: ...a k Vm Vs 4 The value of k is then multiplied by 1024 and rounded to the nearest whole number 5 Set the value getting in to this parameter calibrate finished For example Vm 300 Vs 2600 then k 2600 300...