Principal Display Panel 

Aero HygenX 

 

RAY 

 

AUTONOMOUS UVC ROBOT 

REGISTRATION NO. 34541 PCPA 

 

KEEP OUT OF REACH OF CHILDREN 

This device is intended for commercial or industrial use only 

READ LABEL AND THIS OPERATING MANUAL BEFORE USING.

 

WARNING - UV radiation emitted at 254 nm from this device 

 

 

 

 

 
 

Reduces micro-organisms on surfaces 

 
 

Aero HygenX Inc. 

217-150 Katimavik Road 

Ottawa, Ontario 

K2L 2N2  

CANADA 

1-800-260-0787 

 
NOTICE TO USER: This pest control product is to be used only in accordance with the directions on 
the  label.  It  is  an  offence  under  the 

Pest  Control  Products  Act 

to  use  this  product  in  a  way  that  is 

inconsistent with the directions on the label.  

 

Summary of Contents for 34541 PCPA

Page 1: ...UAL BEFORE USING WARNING UV radiation emitted at 254 nm from this device Reduces micro organisms on surfaces Aero HygenX Inc 217 150 Katimavik Road Ottawa Ontario K2L 2N2 CANADA 1 800 260 0787 NOTICE TO USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Products Act to use this product in a way that is inconsiste...

Page 2: ...RCRAFT ONLY BEFORE USING THIS DEVICE READ ALL INSTRUCTIONS WARNINGS AND CAUTIONS IN THIS MANUAL AND ON THE PRODUCT LABEL TABLE OF CONTENTS 1 PRECAUTIONS 3 2 FEATURES AND CONTROLS 6 3 OPERATION 8 4 TRANSPORTING THE DEVICE 13 5 BATTERY CHARGING 13 6 MAINTENANCE CLEANING 14 7 TROUBLESHOOTING 18 8 WARRANTY 20 9 SPECIFICATIONS 22 ...

Page 3: ...e Threshold Limit Value TLV for UVC is 6 mJ cm per workday as indicated in the Documentation of the Threshold Limit Values and Biological Exposure Indices 8th Edition Copyright 2020 b This device contains a Lithium Iron Phosphate LiFePo4 Battery To reduce the risk of fire electric shock or injury refer to the MAINTENANCE CLEANING section for instructions on battery replacement To eliminate any pos...

Page 4: ...s equipped with a configurable time delay between directional input on the device until lamp illumination This auto delay allows time for the operator to exit the aircraft and close the aircraft door before the lamps commence warm up The default value for the auto delay is 30 seconds The auto delay can be set to any desired time interval in seconds between directional input and lamp illumination O...

Page 5: ...r moisture dust ingress The environmental cover should be in place when the device is being transported outdoors Amber Warning Lights During the start up sequence amber flashing lights on either end of the top cover illuminate indicating that the UVC lamps are now armed and the system is powered for use The start up sequence is initiated by ensuring the Emergency Pushbuttons are UP followed by the...

Page 6: ...d Auto pause Master Power Switch Full Power Disconnect REAR Camera Situational Awareness Human Detection Emergency Push Button UVC and Drive Unit Power Down REAR Lidar Autonomous Guidance REAR Sonar Object Detection Battery Charging Receptacle Autonomous Robotics ...

Page 7: ...7 FRONT VIEW FRONT Camera Situational Awareness Human Detection FRONT Lidar Autonomous Guidance FRONT Sonar Object Detection FRONT Touchpad Simple Built in Touch Screen ...

Page 8: ...s or following carriage of individuals who have been exposed to an infectious disease c Ensure all personnel involved in the task familiarize themselves with the required safety precautions and operating instructions associated with the device Refer to PRECAUTIONS section above d Treatment of an aircraft using UVC light is based on the assumption of a clean aircraft Visible soil and liquid spills ...

Page 9: ...ws for a minimum of 6 dual pass treatment before recharging is required START SEQUENCE Aero HygenX RAY Autonomous UVC Robot has 3 modes of Operation 1 FORWARD Aero HygenX RAY Autonomous UVC Robot will move down the aisle away from the operator until detecting a wall or obstruction and will then come to a STOP 2 LOOP Aero HygenX RAY Autonomous UVC Robot will move in the direction of the chevron lab...

Page 10: ...top of the unit The device will now go through a short System Health Check When the System Health Check is complete the RAY logo turns green and the device is ready for use The operator then selects a directional command either FORWARD REVERSE or LOOP The touchpad now reverts to the Countdown mode shown here commencing the auto delay of 30 seconds before lamp warm up This countdown allows time for...

Page 11: ...reatment the STOP icon on the touchpad should be pressed When the lamp warm up is complete default warm up time is 2 minutes the treatment will commence The lamps will be fully illuminated and Aero HygenX RAY Autonomous UVC Robot will start moving down the aisle If Aero HygenX RAY Autonomous UVC Robot has been used in the previous 5 minutes lamp warm up reverts to just 30 seconds ...

Page 12: ...n the Master Power Switch ON Power up is verified by amber flashing lights on the top of the unit If the amber lights are not on ensure both red Emergency Push Buttons are in the UP position g Initiate START sequence by selecting one of the operation modes i e FORWARD REVERSE or LOOP h Exit the aircraft and close the aircraft door within 30 seconds of initiating the START sequence i To monitor the...

Page 13: ...ch is selected OFF refer to REAR VIEW image in section above entitled FEATURES CONTROLS for location of Master Power Switch d If the aircraft is parked on an open ramp ground staff may load Aero HygenX RAY Autonomous UVC Robot through the aircraft door as shown NOTE Carry handle at the front is mid way up the unit Carry handle at the aft is on the lower portion of the unit 5 BATTERY CHARGING a Cha...

Page 14: ... Power Switch is OFF b Open side panel of Aero HygenX RAY Autonomous UVC Robot With panel open top of battery will be visible c Locate the large red Handle d Pull on the red handle while holding on to the battery side portion of the connector to separate the two parts as shown in the photo Single Push Latch Access ...

Page 15: ...n g Attach the Velcro strap around the battery h Connect the new battery by pushing the red connectors together reverse of removal i Ensure correct polarity per image j Close side panel k Ensure Aero HygenX RAY Autonomous UVC Robot can be powered on l Ensure battery disposal is in compliance with local laws ...

Page 16: ...el c Pull up gently on the bulb requiring replacement holding on to the lamp as close to the base as possible d When raised gently pull the white ceramic connector apart from the 4 pins at the base of the lamp e Slide the new lamp into the ceramic connector ensuring all pins are securely connected Take note of the key pattern of the connector it will fit only one way ...

Page 17: ... a soft dry cloth b For more stubborn stains use a soft cloth slightly dampened with a solution of mild soap and warm water Do not use alcohol or acetone based cleaners c Do not allow water or other liquids to pool or enter the unit from the top panel d Ensure the inside electronic components are not exposed to water or moisture ...

Page 18: ...Internal issue Reset unit by turning Master Power Switch Off for 10 seconds then on All Lamps fail to illuminate Possible lamp connection issue Check that both Emergency Push Buttons are UP Check that the Main Battery Switch is ON Half of the lamps fail to illuminate Possible ballast failure Reset unit by turning Master Power Switch Off for 10 seconds then on Single lamp fails to illuminate Single...

Page 19: ...l command Internal systems not ready 1 Wait 30 seconds and re attempt directional command 2 Reset unit by turning Master Power Switch Off for 10 seconds then on Aero HygenX RAY Autonomous UVC Robot does not maintain directional control in aircraft aisle or displays erratic movement Internal system issue Check Lidar ports to ensure there are no obstructions Remove obstruction Ensure caster brakes a...

Page 20: ...parties products including software sold by AHX carry only the original manufacturer s warranty applicable to the Customer Any Product repaired or replaced under warranty is only warranted for the period of time remaining in the original warranty for the Product The warranty provided herein shall extend to any Product which has proven to be defective and has failed through normal use but excludes ...

Page 21: ...l diligently return the Product with prepaid shipping arrangements and sufficient insurance against the loss or further damage to the Product to AHX s facility Any Product which has been returned to AHX but which is found to meet the applicable specification for the Product and not defective in workmanship and material may be subject to AHX s standard examination charge in effect at the time and m...

Page 22: ... Counter Clockwise Maneuverability 360 degree WiFi Yes Bluetooth Yes Cameras 2 1080p 30fps Sonar Yes Lidar Yes Autonomous Control Yes Manual Control Touchpad Cloud Service HygenX Stream Electric Charge Power 400W 100 240VAC Charge Time Full Charge 3 33 hours Battery Life 2000 hours Safety Human Detection Auto Shut Off Yes UVC Indication Light Yes Emergency Kill Switch Yes Battery Disconnect Switch...

Page 23: ...NUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN NOTICE TO USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Products Act to use this product in a way that is inconsistent with the directions on the label Designed and Manufactured by AEROHYGENX 217 150 Katimavik Road Ottawa Ontario Canada K2L 2N2 1 800 260 0787 E...