background image

 

MANUFACTURER 

RECOMMENDATION 

DV WT9 10B / 2019, Rev. 0 

Sheet: 

Sheets: 


10

 

 

SUBJECT: 

Installation of canopy lock with safety latch and sensor. 
 

AFFECTED: 

All aircraft WT-9 Dynamic. 

 

REASON: 

When improper execution of canopy latching and locking point during before takeoff procedure, the canopy 
may not be properly locked. The main latch is only partially plugged-in the canopy lock socket what may 
result under certain conditions in canopy opening during flight. 
 

COMPLIANCE: 

Optional. 
 

WEIGHT AND BALANCE: 

Weight change: 

Negligible 

 

 

Moment change: 

Negligible 

 

 

 

REQUIRED ACTION: 

Install new canopy lock with safety latch and sensor, that minimize the risk of canopy opening during flight 
by two ways: 

  Indication of insufficient plug-in of main latch (check lamp on the instrument panel) 

  Safety latch holding the main latch after plug-out from the canopy lock socket. 

The system of canopy lock with a sensor indicates insufficiently locking of the canopy and the safety latch 
prevents  unintentional  opening  of  the  canopy.  The  system  does  not  substitute  properly  execution  
of canopy latching and locking point during before takeoff procedure! 

In the case of installation difficulties contact the aircraft manufacturer at 

service@aerospool.sk

. 

Summary of Contents for WT-9 Dynamic

Page 1: ...ligible Moment change Negligible REQUIRED ACTION Install new canopy lock with safety latch and sensor that minimize the risk of canopy opening during flight by two ways Indication of insufficient plug...

Page 2: ...opy lock socket 2 from the fuselage 1 2 Place the template Fig 2 for installation hole enlarging on the fuselage and align with the rivet holes template in the scale 1 1 is in the Appendix 1 UP symbol...

Page 3: ...he instrument panel 2 4 From the rear drill the hole in the fuselage stiffener for access to adjusting screw 10 Fig 5 of sensor 2 5 Place the canopy lock socket 1 Fig 3 into the fuselage 2 and attach...

Page 4: ...MANUFACTURER RECOMMENDATION DV WT9 10B 2019 Rev 0 Sheet Sheets 4 10 Fig 4 Fig 5 7 8 8 10 9 9...

Page 5: ...MANUFACTURER RECOMMENDATION DV WT9 10B 2019 Rev 0 Sheet Sheets 5 10 Fig 6 Fig 7 1 3 12 13 11...

Page 6: ...ect the sensor of canopy lock socket to the check lamp and circuit breaker according to wiring diagram Fig 10 3 1 3 Install the check lamp and circuit breaker on the instrument panel 3 1 4 Mark the ch...

Page 7: ...to the reference position i e closely to the entry hole of canopy lock socket 6 4 3 Plug in the main latch 10 5 0 3 mm deep into the canopy lock socket 12 and fix it in this position 4 4 By means of a...

Page 8: ...MANUFACTURER RECOMMENDATION DV WT9 10B 2019 Rev 0 Sheet Sheets 8 10 5 Wiring diagram Fig 10...

Page 9: ...131 24 0 2 Cable 3 wire T 0 24 6 m 44A0111 22 9 Cable 1 wire 0 38 2 m DB 6 63 FASTIN AWG 16 14 DURASEAL B 106 4632 1 pc DR 6 40 Cable eye 4 6 4 3 DURASEAL B 106 1402 1 pc DR 6 50 Cable eye 4 6 5 3 DUR...