Page 1: ...TM Air Purifier Owner s Manual AAP 301 Indoor Air Purification Systems Crescent Technocrats Customer Care Toll Free 1800 102 3715 Email customercare aira india com ...

Page 2: ...xperienced engineers who aspire to achieve maximum customer satisfaction utility value and reliability of the products We hope you enjoy our product and we will be happy to receive your valuable comments feedbacks that you may have This will help us to improve our products quality performance and the technical support that we provide to every customer If you have any questions while using this pro...

Page 3: ...stallation Instructions 7 5 Maintenance of Filters 8 6 Functions 8 7 Precautions 9 8 Hazardous 9 9 Warning 10 10 Attention 11 11 Filter Replacement 12 12 Intelligent odor sensing system memory reset instructions 12 13 Troubleshooting 13 14 Warranty Terms and Conditions 14 15 General 15 16 Post Warranty 15 ...

Page 4: ... Purification Method 1 Pre Filter 2 High Efficiency HEPA 3 Cellular activated carbon 4 Cold catalyst 5 Ultraviolet sterilizer 6 Anion Generator 2x107pcs cm3 negative ion Wind Speed High speed Medium Speed Low speed CADR 190m3 h for PM2 5 Dimension L335 W180 H505mm Net weight 5Kg Application Area 320 sqft ...

Page 5: ...elf does not change during the decomposition action thus the cold catalyst is long lasting and can be valid up to 5 years 4 The catalyst material is regularly used in non toxic non corrosive and non inflammable materials thus it is safe to use It works under normal condition and produces only water and carbon dioxide 5 The cold catalyst can be used to deal with formaldehyde ammonia benzene TVOC hy...

Page 6: ...Details 1 Control panel 6 Silent 11 Handle 2 Quality Display Window 7 Timer 12 Anion Air Outlet 3 On Off 8 Sterilize 13 Rear Case 4 Anion 9 Front plate 14 Remote Controller 5 Speed 10 Middle case 15 Power cord ...

Page 7: ...d Carbon Filters back into the product 5 Put Filter 2 HEPA Filter back into the product Note Please ensure that the tab ribbon side is facing you 6 Make sure that the filters are installed in position Turn the buckles to fix the Filters 7 To install the front panel put the bottom into the host buckle and close the Front panel The front panel will be held by built in magnets ...

Page 8: ...en display and the machine is in stand by mode 3 When pressing the power button the design will flash in the digital screen 4 When pressing the timer button the machine is turned on and the intelligent odor sensor control is started too The machine will adjust the speed automatically according to the air quality The timer starts from 1 12 hours the power will be turned off when time expires 5 The ...

Page 9: ...The intelligent odor sensor control is turned on automatically at the same time 8 Press the Sterilize button to turn on the UV germicidal light and the Sterilize icon will be shown on the display screen The intelligent odor sensor control is turned on automatically at the same time Precautions Before using the product please read this manual thoroughly and retain it for future reference Hazardous ...

Page 10: ... machine 2 If the power cord is damaged please discontinue the use of the product and contact the authorized agent to fix it 3 Do not block the air inlet or outlet with any objects 4 For safety precaution please do not allow children or people who have insufficient knowledge to handle the equipment unsupervised ...

Page 11: ...he product with hard objects especially the air inlet and the front plate 8 The odor sensor area should be cleaned frequently to prevent clogging 9 Do not use this product while using insect repellent sprays inside the room or in a place filled with flammable gas 10 Do not use this product near gas appliances heating devices or near stove 11 Please unplug the socket after use and before cleaning 1...

Page 12: ...Intelligent odor sensing system memory reset instructions If the air quality indicator displays red color and the machine power is cut off suddenly you might have to reset the intelligent memory Otherwise the red color display will remain 1 Unplug the machine and wait for 15 20seconds Plug again and start the machine and press negative ion timer or Sterilize 2 Keeps the machine working for 15 seco...

Page 13: ...ficantly improved after long run of the machine Check the filter layers installation sequence Filters are worn out you need to replace all the filters The filters should be exposed to the sunlight periodically When should I replace the filters Activated Carbon Filter the surface is dirty and fades in color The tiny hole of the cold catalyst is blocked by dust or the color of the active carbon has ...

Page 14: ...al operation of the goods and their proper and prescribed use The warranty does not cover or extend to defects which are determined by the Company or its authorized agents occurring or resulting from or attributable to negligence abuse misuse faulty care operation or maintenance or repairs alterations to the goods or any part thereof by others or the use of the goods on electrical supply for which...

Page 15: ... After the warranty period the customer has the option of calling the Company s Service Centre and having the goods serviced on an actual basis i e by paying the Labor cost and Spares needed to attend to that Service Complaint Call at the prevailing Company rates Such Service will be rendered by the company in towns places where the Company has its Service Centers 2 The Company will provide free s...

Page 16: ...16 Imported Marketed and Serviced by Crescent Technocrats C 84A Sector 8 NOIDA 201301 Phone 1800 102 3715 Email customercare aira india com Website www aira india com ...