background image

English  

 

 

 

 

Summary of Contents for AC-ZP112

Page 1: ...English ...

Page 2: ...n 4 5 Structure 5 6 Operation 6 7 Maintenance 15 8 Trouble Shooting 18 9 Safety Cautions 19 10 Special Guide Line 20 11 After Sale Service 21 12 Electric Circuit Drawing 22 Notice Any maintenance should be returned to the dealer or factory Attention Please read this instruction carefully before use ...

Page 3: ...sories 1 inner air exhaust adaptor 1 pc 2 air exhaust duct 1 pc 3 adaptor 1 pc 4 mounting duct 1 pc 5 window kit 1 pc 6 cap cover 1 pc 7 remote controller 1 pc 8 instruction manual 1 pc 9 water plate 1 pc 1 ...

Page 4: ...er novelty practicality and convenience principles to satisfy the needs for convenient efficient and mobile small size air conditioner The part makes the cooling special obvious It features easy using no need for installation and convenient maintenance The unit is highly competitive to other cooler capable products With tidy structure multiple functions and reasonable ventilation design the unit m...

Page 5: ...me low temperature low pressure liquid After absorbing the heat of air in the surface of evaporator A forced air cooling process too room air passes evaporator surface its heat is absorbed by refrigerant in tube it cools down and flows into room to lower the room temperature The low temperature low pressure liquid is evaporated in the evaporator The refrigerant becomes vapour and flows back to com...

Page 6: ... capacity measured at ambient temperature Db 27 C 19 C Wb 27 C 19 C indoor and outdoor the same Db means Dry Bulb that is testing in dry environment Wb means Wet Bulb that is testing in wet environment 2 Noise level is measured at the point where 1 0 meter away from the front of the machine In cooling mode 3 Air exhaust duct tore down pump work fan power consumption is measured when fan runs at hi...

Page 7: ...let 7 Exhaust air outlet 8 Cord Hanger 9 Water stopper 9 7 8 5 6 10 Inner air exhaust adaptor connect with air exhaust duct 11 and exhaust air outlet 7 11 Air exhaust duct 12 Adaptor 13 Mounting Duct 14 Window kit 15 Water plate 16 Remote controller 13 12 11 10 15 16 14 ON OFF 5 ...

Page 8: ...st desired room temperature and it will display in LED window correspondingly the temperature adjustment range is 15 C 31 C 60 90 F When unit is setting at AUTO running mode the default cooling temperature is 23 C 68 F Press the TEMP UP DOWN button at the same time the temperature display will be shown between C and F 6 TIMER button TIMER OFF When unit under running mode press timer button to set ...

Page 9: ...under running and the unit is ready Temp Button Press this button once setting room temperature will increase 1 Press this button once setting room temperature will decrease 1 TIMER _ SPEED SWING MODE F F Button Every time press this botton the machine control panel shows the temperature in C or F on the conversi Remote control Auto mode The microprocessors control the compressor and fan motor on ...

Page 10: ...riginal speed TIMER _ SPEED SWING MODE F 1 Press ON OFF button the system starts to run 2 Press Temp button to set the desired room temp 3 Press MODE button choose cooling mode 4 Press SPEED button set fan speed Remote control Fan mode F MODE SWING SPEED _ TIMER 2 Press MODE button choose Fan mode 1 Press ON OFF button the system starts to run 3 Press Speed button choose desire fan speed Fan mode ...

Page 11: ...der running press Timer button to set unit auto OFF time 3 When set auto OFF time at 12 hours pressTimer button once more set OFF time will be canceld 4 When the unit is not under running press Timer button to set auto ON time 2 Press Timer button once set auto OFF time will change 0 5 hour from 0 5 hour to 12 hours 5 press timer button once set auto OFF timer will change 0 5 hour to 12 hours 6 wh...

Page 12: ... environmental hazard Remote control inserting the batteries 1 slide the cover as shown in figure 2 insert two new non rechargeable batteries being careful to place them in the correct position and 3 put the cover back on letting it slide into its original position 4 the display will show all of the remote control s symbols for several seconds The operation of Air exhaust duct assembling M ounting...

Page 13: ... from window see figure A Open window for a small angle to put bend mounting duct and fit it on the window 50cm 50cm A 50cm B 2 exhaust hot air from the door see figure B Open door to an appropriate angle to fit air exhaust duct outside For the wide open using air exhaust duct can put on ground directly When not Using the unit unassembled air exhaust duct from unit and store it carefully 11 ...

Page 14: ...e nut anti clockwise and unscrew such as Fig 1 2 adjust the washer on board 1 at the sliding groove on board 2 and then insert the fixation board 2 in the fixation board 1 such as fig 2 3 adjust according to own window size and fix nut on the fixation board 1 clockwise such as fig 3 12 ...

Page 15: ... to improve modify some aspects of the installation procedures for certain types of window Take the example with three parts of tracks Please refer to see the figures for minimum and maximum window openings Window Slider K it M inimu m 58cm M aximu m 162cm H orizontal window 50cm 50cm Perpendicu lar window Window Slider K it M inimu m 58cm M aximu m 162cm 50cm 50cm 13 ...

Page 16: ...r exhaust duct is shorter 2 please make sure the air exhaust duct is not distorted or flow back the hot air to increase the temperature of the body If so the unit will stop running automatically 3 please make sure not to use other type of air exhaust duct or over extend the exhaust duct Otherwise the unit working efficiency will decrease 14 ...

Page 17: ...r is blocked with dust the airflow volume will decrease It is better to clean the filter for every two months Open the air filter Take out the air filter cover from back air inflow vent Air Filter Clean Wash the air filter gently with warm water with a neutral detergent and dry it thoroughly in a shaped place Mounting Insert the air filter cover into air flow vent Clean the unit surface by using l...

Page 18: ...tart cooling mode please use the following way to empty the water Drainage Hole Rubber Plug Drainage Knob Water Plate A water plate drainage 1 turn off the unit 2 horizontally place water plate underneath drainage hole 3 disconnect drainpipe through drainage knob and rubber plug water will Automatically flow out 4 when the water is empty push rubber plug back to the drainage hole 5 connect drainag...

Page 19: ...mm diameter plastic pipe and connect with the drainage pipe Rubber Plug E xtend Drainage Pipe Diameter 18mm Drainage Pipe Drainage Knob Drainage Pipe Important notice 1 in order to extend the life of the product please drain all the condensed water while not use the unit for some time 2 the unit adapts auto drainage system please pay attention the signals on display when the air is too humid above...

Page 20: ... no cool air coming out Room temperature is lower than set temperature Make the setting temperature lower than the room temperature if it still does not work call the local technician for repairing Error code E1 in LED window Environment temperature sensor is broken Replace the temperature sensor Error code E2 in LED window temperature sensor on the evaporator is broken Replace the sensor Error co...

Page 21: ... risk of electromagnetic interface 6 Do not use unit with the air outlet too close to walls or cover the outlet to avoid overheating 7 Do not use the unit in a very crowded room 8 Do not use the unit directly under sunshine to avoid surface color fading 9 Do not use the unit in water or near water to avoid leakage of electricity 10 If the supply cord is damaged it must be replaced by the manufactu...

Page 22: ...y it is not the unit s quality problem The unit can only work efficiently in certain room area see technical specification 4 In order to prolong the unit s lifetime please empty the water completely in the water tray at the bottom of the unit while the unit is not going to use for a long period of time 5 The unit can drain water automatically It is not necessary to use the hose to drain the water ...

Page 23: ... help from your local dealer or service center Maintenance After running for several seasons there will be dust covered in the air filter This will reduce the airflow volume and influence the cooling efficiency of the unit Please clean the air filter occasionally Delete the rest message 21 ...

Page 24: ...Electric Circuit Drawing 22 ...

Page 25: ...c product By ensuring the correct disposal of this product you will help prevent potentially hazardous to the environment and to human health which could otherwise be caused by unsuitable waste handling of this product The recycling of materials will help conserve natural resources Please do not therefore dispose of your old electrical and electronic equipment with your household waste For more de...