1
Technote10: Setting up DM-102 COFDM Modulators with PS-011
DM-102 is a fully agile Digital Modulator which is designed to convert 2 AV
signals into a digital modulated channel.
IMPORTANT:
Layout of the modules must be as shown above. Power Supply (FA-312) must
be located on the far left hand side and launch amplifier (PA-720) must be the next module in
the chain. Please look at the layout above. A limit of 6 DM-102 modules can be powered by
one FA-312. If FA-310 is being used only 3 modules is the limit due to power consumption.
AIM PROGRAMMER TO IR SENSOR LOCATED ON EACH DIGITAL
MODULATOR WHEN PROGRAMMING
Programming of Modules
Ensure the following prior to programming:
•
It is necessary to connect all the modules to the support frame SP-226 (code 9120130)
for the system to function.
•
It is also recommended that you make the earth connection to the building using a cable
with a section of at least 4 mm.
•
Ensure that you have the Alcad programmer PS-011 with
firmware version 1.11
or
later.
•
Power supply/Control cable must be plugged into each module.
DO NOT ADD OR
REMOVE
modules without disconnecting mains supply power from wall outlet. Always
disconnect the equipment, and then reconnect it to the mains supply. Failure to do so
can cause equipment to fail.
Launch Amplifier
Power Supply
IR Sensors