background image

Publication 1784-IN036B-EN-P - May 2001

Installation Instructions

DeviceNet CompactPCI Communication Interface 
Card

Catalog No. 1784-CPCIDS

To the Installer

The DeviceNet CompactPCI

 Communication Interface Card (catalog number 

1784-CPCIDS) is a Compact Peripheral Component Interconnect (CompactPCI) 
card. The card is an open-bus interface that provides DeviceNet configuration and 
I/O scan capabilities.

This document contains:

topic

page

Important User Information

2

Rockwell Automation Support

3

Related Publications

4

Purpose

4

Audience

5

System Requirements

5

Communication on DeviceNet

5

Compliance to European Union Directives

5

Use Care When Handling the Card

6

Terminology

7

Verify the Contents of Your 1784-CPCIDS Order

7

Introducing the 1784-CPCIDS Communication Interface Card

8

Install the 1784-CPCIDS Card

8

Connect to the Network

10

Install the 1784-CPCIDS Driver and IOLinx in Windows NT

11

Summary of Contents for DeviceNet CompactPCI 1784-CPCIDS

Page 1: ...eviceNet configuration and I O scan capabilities This document contains topic page Important User Information 2 Rockwell Automation Support 3 Related Publications 4 Purpose 4 Audience 5 System Requirements 5 Communication on DeviceNet 5 Compliance to European Union Directives 5 Use Care When Handling the Card 6 Terminology 7 Verify the Contents of Your 1784 CPCIDS Order 7 Introducing the 1784 CPCI...

Page 2: ...responsibility or liability to include intellectual property liability for actual use based upon the examples shown in this publication Allen Bradley publication SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Allen Bradley office describes some important differences between solid state equipment and electromechanical devi...

Page 3: ...y major country around the world Contact your local Rockwell Automation representative for sales and order support product technical training warranty support support service agreements Obtain Pre Sales Product Support If you need to contact Rockwell Automation for pre sales product support try one of the following methods Call your local Rockwell Automation representative Network pre sales suppor...

Page 4: ...m and placing an order calling 800 963 9548 USA Canada or 001 320 725 1574 outside USA Canada Purpose Use this document to learn how to install and use the DeviceNet CompactPCI Communication Interface Card type of technical support access at Personalized Service Call your local Rockwell Automation representative Post sales Technical Support 1 440 646 5800 Email your questions to racleasktheexpert ...

Page 5: ...ified Class 2 power supply You also need Windows NT 4 0 with Service Pack 5 or later or Windows 2000 with Service Pack 1 or later one open CompactPCI slot approximately 2 MB disk space RSNetWorx for DeviceNet V2 11 51 or later RSLinx V2 10 118 or later Communication on DeviceNet You must have IOLinx for the 1784 PCIDS Card or RSLinx application software to communicate on a DeviceNet network with a...

Page 6: ...ts of EN 61131 2 Programmable Controllers Part 2 Equipment Requirements and Tests For specific information required by EN 61131 2 see the appropriate sections in this publication as well as the following Allen Bradley publications Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Automation Systems Catalog publication B111 This equipment is classified as open equipment and...

Page 7: ...in which it was shipped Terminology Verify the Contents of Your 1784 CPCIDS Order With this package you should receive 1784 CPCIDS card terminal block connector driver and utility IOLinx CD for the 1784 CPCIDS card DeviceNet CompactPCI Communication Interface Card Installation Instructions publication 1784 IN036B EN P IMPORTANT Remember a computer with ac power disconnected is not a grounded objec...

Page 8: ... a Compact Peripheral Component Interconnect CompactPCI open bus interface card Install the 1784 CPCIDS Card IMPORTANT Be certain that you know how to install hardware in your computer configure the computer s options before you install the card Consult your computer s documentation for specific information 30628 M S The 1784 CPCIDS Communication Interface Card provides DeviceNet configuration and...

Page 9: ... in the computer Access the Computer s Expansion Slots To install the 1784 CPCIDS card you must access the computer s expansion slots Refer to your computer s user guide for instructions on how to 1 Power down the host computer by turning off the power switch 2 Select a vacant CompactPCI expansion slot 3 Remove the slot s expansion cover by loosening the screws on the top and bottom of the cover I...

Page 10: ...e rail and card lock 3 Tighten the top and bottom expansion cover screws 4 Turn on the computer to make sure it powers up correctly Connect to the Network This figure and table show the necessary network connections you make to the card The label on the retaining bracket is color coded for easy wiring pin number wire color abbreviation description 1 black V 24V dc power return 2 blue CAN_L data lo...

Page 11: ...on which previous version of IOLinx was installed double click on one of the following to remove it 1784 PCIDS Drivers for IOLinx IOLinx for the 1784 PCIDS Card 5 Select Yes to uninstall IOLinx IMPORTANT Be sure that your 1784 CPCIDS card is properly installed Refer to Install the 1784 CPCIDS Card on page 8 IMPORTANT Before you install the new driver and IOLinx you must uninstall any earlier versi...

Page 12: ...ep 5 on page 12 3 Select Start Run 4 At the Run pop up menu type d setup where d is your CD ROM drive letter 5 You see the IOLinx for the 1784 PCIDS screen IMPORTANT We recommend that you exit all Windows programs before running this Setup program TIP The CD ROM supports Windows Autorun If you have Autorun configured once the CD is inserted into the CD ROM drive the installation will automatically...

Page 13: ... Communication Interface Card 13 Publication 1784 IN036B EN P May 2001 6 Click on Install Products You see this screen 7 Click on Install IOLinx for the 1784 PCIDS Card 8 Follow the on screen instructions to install IOLinx ...

Page 14: ...stalling your 1784 CPCIDS card you see the Found New Hardware Wizard 2 Click Next IMPORTANT Use this procedure only if this is the first time that you are installing the 1784 CPCIDS driver and IOLinx on this computer Otherwise use the Update the 1784 CPCIDS Driver and IOLinx in Windows 2000 procedure on page 18 instead of this procedure IMPORTANT Be sure that your 1784 CPCIDS card is properly inst...

Page 15: ...DeviceNet CompactPCI Communication Interface Card 15 Publication 1784 IN036B EN P May 2001 3 Click on Search for a suitable driver for my device recommended 4 Click Next 5 Select Specify a Location ...

Page 16: ...on your CD ROM drive insert the CD ROM into the computer s CD ROM drive the Setup Utility will start automatically Click anywhere in the Wizard screen to bring it back on top of the Setup Utility window you are installing IOLinx from a compressed file download IOLinx from http www ab com networks iolinx and unzip the files into a temporary directory IMPORTANT To ensure that the card works properly...

Page 17: ... the CD in the computer s CD ROM drive 2 If Autorun is configured for your CD ROM drive go to step 5 on page 17 3 Select Start Run 4 At the Run pop up window type d setup where d is your CD ROM drive letter 5 You see the IOLinx for the 1784 PCIDS screen 6 Click on Install Products You see this screen ...

Page 18: ...ich previous version of IOLinx was installed double click on one of the following to remove it 1784 PCIDS Drivers for IOLinx IOLinx for the 1784 PCIDS Card IMPORTANT Use this procedure only if you have previously installed the 1784 CPCIDS driver and IOLinx on this computer If you have not previously installed the 1784 CPCIDS driver and IOLinx on this computer use the Install the 1784 CPCIDS Driver...

Page 19: ...Update the Driver 1 Right click on My Computer 2 Select Manage 3 On the Computer Management window that appears select Device Manager TIP If you are prompted to remove unused shared files select No to All if then IOLinx version 1 14 or earlier was installed go to step 4 on page 20 IOLinx version 1 15 or later was installed go to step 5 on page 20 ...

Page 20: ...CIDS card that you are updating and select Properties c Go to step 6 5 If IOLinx version 1 15 or later was installed follow this procedure a Select Allen Bradley PCI Family b Right click on the Allen Bradley 1784 PCIDS that corresponds to the 1784 CPCIDS card you are updating and select Properties c Go to step 6 Click on Other Devices to expand it Then right click on Network Controller Click on Al...

Page 21: ...dio button 9 Click Next 10 Select the Have Disk button if then you are installing from CD ROM and Auto Insert Notification a k a Autorun is enabled on your CD ROM drive insert the CD ROM into the computer s CD ROM drive the Setup Utility will start automatically Click anywhere in the Wizard screen to bring it back on top of the Setup Utility window you are installing IOLinx from a compressed file ...

Page 22: ...ve 2 If Autorun is configured for your CD ROM drive go to step 5 on page 23 3 Select Start Run TIP When you close the Properties screen you may be prompted to restart your computer If you get this prompt restart your computer before using this updated driver IMPORTANT To ensure that the card works properly you must install IOLinx as described on page 22 IMPORTANT We recommend that you exit all Win...

Page 23: ...May 2001 4 At the Run pop up window type d setup where d is your CD ROM drive letter 5 You see the IOLinx for the 1784 PCIDS screen 6 Click on Install Products You see this screen 7 Click on Install IOLinx for the 1784 PCIDS Card 8 Follow the on screen instructions to install IOLinx ...

Page 24: ...uts using the device status screen Start the Test Application The test application is automatically installed as part of the driver installation procedure although it does not show up as a shortcut on your screen To start the test application click Start Programs Rockwell Software IOLinx IOLinx for DeviceNet DeviceNet Test The test application assumes that you have the card installed the network i...

Page 25: ...as been configured Create View To go online follow these steps 1 From the Setup menu select Create View 2 Select Port Names 3 Select Message Type Input Output or Input Output 4 Select Privilege Read Only Read Write 5 Click OK You see a message box that tells you that Operation was successful Scanner Mode The Port Mode window displays the current mode of the scanner Run Idle No View Once you create...

Page 26: ...lly updated when inputs change Write Outputs Write Outputs lets you write as many as 2048 bytes to the output image table of the scanner using manual data entry in a dialog box The scanner must be in Run Mode for writes to be seen at the output device 1 Select the desired byte s 2 Type in the desired value s 3 Press the Write button The transfer is performed TIP The hexadecimal number on the left ...

Page 27: ...ommunicating If you double click on an empty node you see the response OK or not in scan list Interpret Status Indicators LEDs The three status indicators on the card give you information about your network and its connections This figure identifies each status indicator The tables on pages 28 through 29 outline the indicator condition and the corresponding status and explain what each condition m...

Page 28: ...g red1 output s faulted input s faulted One or more outputs are faulted and may be in the fault state One or more inputs are faulted and may be in the fault state red output s forced off input unrecoverable fault One or more outputs are forced off may be an unrecoverable fault One or more inputs has an unrecoverable fault 1 The flash rate of the LED is approximately 1 flash per second The LED shou...

Page 29: ...d the Dup_MAC_ID test yet The device may not be powered look at the Module Status LED flashing green1 online not connected Device is online but has no connections in the established state The device has passed the Dup_MAC_ID test is online but has no established connections to other nodes green link okay online connected The device is online and has connections in the established state flashing re...

Page 30: ...erating 2 non operating 30G peak 11 ms 50G peak 11 ms Agency Certification when product or package is marked Certified Component Process Control Equipment Certified Component Class I Division 2 Groups A B C D UL Recognized Industrial Control Equipment Marked for all applicable directives 1 The DeviceNet power supply must be compliant with the requirements for CLASS 2 as defined in NFPA 70 National...

Page 31: ...oup PICMG is a registered trademark of the PCI Industrial Computer Manufacturers Group PCI is a trademark of the PCI Special Interest Group DeviceNet is a trademark of the Open DeviceNet Vendor Association ODVA IOLinx is a trademark of Rockwell Automation RSNetWorx is a trademark of Rockwell Software Inc Windows NT and Windows 2000 are trademarks of Microsoft Corp ...

Page 32: ... If this product contains batteries they must only be changed in an area known to be nonhazardous Informations sur l utilisation de cet équipement en environnements dangereux Les produits marqués CL I DIV 2 GP A B C D ne conviennent qu à une utilisation en environnements de Classe I Division 2 Groupes A B C D dangereux et non dangereux Chaque produit est livré avec des marquages sur sa plaque d id...

Page 33: ...DeviceNet CompactPCI Communication Interface Card 33 Publication 1784 IN036B EN P May 2001 Notes ...

Page 34: ...34 DeviceNet CompactPCI Communication Interface Card Publication 1784 IN036B EN P May 2001 Notes ...

Page 35: ...DeviceNet CompactPCI Communication Interface Card 35 Publication 1784 IN036B EN P May 2001 Notes ...

Page 36: ...Publication 1784 IN036B EN P May 2001 PN 957555 03 Supersedes Publication 1784 5 36 May 1998 2001 Rockwell International Corporation Printed in the U S A ...

Reviews: