AlphaRefuge™ 2100 Series (V3) Area of Refuge and Rescue
Assistance system Installation, Use and Wiring Instructions
Pre-Installation Requirements:
• 120V Power
• Determine Communication:
1.
Dedicated analog phone line from POTS, PBX, or Central Office.
2. VoIP - requires use of Alpha Model
ABL-VOIP
to connect Master to VoIP phone system.
3.
Internal Intercom (no offsite calling) - requires Alpha Model
2100-LINESIM.
• Twisted, shielded 22 or 24 AWG wire cabling to connect each Refuge Call Box (RCB) to the
Refuge Command Center (RCC)
• Use 24V 18/2 wire for powering the Emergency Phones from the 24VDC Power Supply.
NOTE: Terminals and markings shown in this manual may not be in the order in which they appear
on the actual equipment. When installing, observe all national and local electrical and building
codes.