GSM LIFT COMMUNICATION SYSTEM 

GSM Lift Watch 

Voice

 

 
 

 

 

Installation and programming manual v3.2

  

from fw 127

 

 

 

Summary of Contents for GSM Lift Watch Voice

Page 1: ...GSM LIFT COMMUNICATION SYSTEM GSM Lift Watch Voice Installation and programming manual v3 2 from fw 127 ...

Page 2: ...1 module 135 x 66 x 22 mm Functionality At installation place is not necessary phone line availability Possibility of Voice communication for cabin shaft and machine room ReMicA1 ReMicAS1 ReMicB PREPOJ simultaneous connection of all units with operator connection machine room shaft cabin only Changeable back up Accumulator ACU User friendly installation as same as settings for start just saving 1 ...

Page 3: ...of call cancel locally technician or remotely SMS according to the standard EN 81 28 2018 During the Emergency state call blocking is cancelled incoming calls can be made from any number Outgoing calls are not blocked Notification SMS with low voltage info adjustable value Announcement SMS with correct voltage info return over setup value Notification SMS with info about low voltage of backup ACU ...

Page 4: ... 1 when you use SIM card from previous model GSM Lift Watch then just insert this SIM into new model GSM LW Voice All settings except SMS will be automatically saved into new GSM LW Voice 2 Insert SIM card into ordinary mobile phone and save on the SIM desired number for emergency call under name MASTER1 eventually TEST1 more details capture programming 3 Start the unit via capture Start the unit ...

Page 5: ...he type of ReMic used and the standard see table The Emergency Lift Communicator message is activated the lift location can be reached The system returns to standby by ending the call with the station The port s I1 I2 on the ReMic see the table is disconnected and the call is terminated message is activated Indication according to used ReMic status Current indications ReMicA ReMicB ReMicAS ReMicL ...

Page 6: ...ed party hang up the call Ports I2 are switch off function EMERGENCY mode is on It is activated message call is terminated After the situation is resolved rescuing the person from the elevator the lift technician terminates the EMERGENCE ALARM status button or SMS and also I1 is open Example 2 Setting Numbers MASTER1 MASTER2 MASTER5 Activation time 3 s Waiting for dialling next number 20 s Emergen...

Page 7: ...ivate emergency call is activated message Emergency call is blocked Try again later please But if the button is pressed for more than 30 seconds the lockout is cancelled and the emergency call is activated EN 81 28 2018 Example1 Blocking is connected to door contact The door are opened port is short circuited Setting Activation time of port short circuit 3s Blocking surveillance after port is deac...

Page 8: ...than 30 seconds the call is made and when blocking Back calling The unit might be activated also by calling to his phone number Connected will be numbers saved on SIM card only Other numbers are ignored Due this is possible even without people in lift cabin assistance make again connection and control situation in lift cabin If the connection is established is replayed message emergency communicat...

Page 9: ... correctly evaluated when surrounding noise is too high any or very small change signal level The test can discover not connected ReMic or short circuited MIC In the same time might be send SMS TEST including info Firmware version Back up ACU voltage Power supply voltage Setup time and date in GLWV GSM operator GLWV temperature Number of service visits with date of last one 1 Input status IN1 Bloc...

Page 10: ...gramed level for longer time than 1 minute Discharged back up ACU information SMS Low Voltage is sends to TEST8 number when Acu voltage decrease under preprogramed level 3 3V The GLW V than works correctly approximately 1 hour When power supply is reactivated after this time the unit behaviour is like when you start it switch ON SMS Power OK is not sends Input change IN1 information SMS with info ...

Page 11: ...ng emergency mode closed relay status indication activation blocking of further activities in the lift The status emergency is possible cancel up settings either by short circuit on port IN1 technician locally after fixing of emergency call problem or remotely by SMS RESET ECALL During this state the pushbutton blocking via IN2 is cancelled also incoming calls only from the allowed numbers the inc...

Page 12: ... preprogramed time adjustable Service OK mode In this mode relay is closed for preprogramed time after short circuit on port IN1 Simultaneously is send SMS SERVICE to number saved under PORTCLOSE and into phone number saved under name SERVICES is saved current date with number of all short circuit on IN1 message Service OK Information of relay status is in STATUS TEST SMS SIM PIN When you desire t...

Page 13: ...GLWV work with PIN PIN2 has no influence to saved data and settings There are stayed saved on the SIM card CAUTION When you insert SIM card with different PIN than 0000 the unit will not work Exception is inserting SIM card with PIN corresponding to unique GSM module So when you switch off GLWV and out the SIM and again insert it back to the same unit then all will work correctly even without PIN ...

Page 14: ...13 Parts of GSM Lift Watch Basic unit GLWV Speaker module ReMicA1 L1 Speaker module ReMicAS1 ...

Page 15: ... Switch for backup ACU Loudness setting Relay screw terminal RESET button ReMic screw terminal SRGM Ports screw terminal LED indication GSM antenna USB connector LED USB SIM card Screws and PSU connector ...

Page 16: ... IN1 Relay contact screw in stand by open NO Shared relay contacts screw COM Contact relay screw in stand by closed NC PWR power REL relay closed IN2 IN2 active short circuit ACT emergency call activated CON connection established picked up ARM emergency button press IN1 IN1 active short circuit GSM signal strength operation ...

Page 17: ...connection at the end of manual Screws for connection to ReMic module in lift cabin connect same marked screws M microphone G ground R speaker S signalling Screws for connection to GLWV basic unit connect together same marked screws see above Screws of emergency button Screws of indicator switch I2 Screws of indicator switch I1 Isolated screws of call activation by voltage 12V Jumpers for LED sele...

Page 18: ... the REMIC unit in level of human head At front of MIC must be hole in table button panel otherwise there will be bad voice quality from lift cabin Isolated screws of call activation by voltage 12V Screws for connection to GLWV basic unit connect together same marked screws see above Screws of emergency button Screws of indicator switch I2 Screws of indicator switch I1 Jumper current limiting of s...

Page 19: ...18 speaker and MIC are installed toward to lift cabin ReMicA L1 Fixing of REMIC at back side of lift cabin button panel for example by screws ...

Page 20: ...ct right place regards to GSM signal strength Lift cabin installation is easier it is not necessary cable from lift cabin to machine room and due this is avoid of interference However you have to provide good signal strength for all lift shaft Keep in mind enough manipulation space for SIM card ...

Page 21: ...hafts etc It caused reduction of GSM signal When you connect magnetic antenna please put it to some bigger iron subject which enables to create bigger GSM signal power It is also important to place antenna out of basic unit to not interference the voice channel by GSM radiation you know it from radio in car ...

Page 22: ...N Programmed SIM via previous item or not programmed SIM insert to the unit see picture and by push lock it up When you have installed ACU let its switch in bottom position switch off Connect power supply Blue LED lights up PWR as same as RED LED on speaker module ReMic Until cca 5 seconds you hear beeps from REMIC speaker Until cca 25 seconds will start flashing yellow LED GSM Until cca 1 minute ...

Page 23: ...SIM Only then MASTERx numbers Push emergency call button calls may not be blocked via Input for emergency call blocking During button press lights red LED alarm ARM on the GLWV and light off red LED on ReMic During button push for preprogramed time necessary for emergency call activation you hear tone of pressed button It lights up yellow LED activation ACT ON ReMic I1 port will be closed and Wait...

Page 24: ...ete unit functionality When you use integrated backup ACU connect him into system by moving its switch to UP position via capture backup ACU FAQ during operation start No LEDs are lighting Power supply error Check power supply and polarity Blue LED lights up LED PWR yellow LED GSM flashing No SIM card inserted message is played SIM card is not inserted or incorrectly inserted Blue LED lights up LE...

Page 25: ...played permanently lighting red LED ARM after button press nothing happen Incorrectly connected or in short circuit output M in cable to ReMic SRGM You hear interference in the call Power voltage filtration is not enough or it is used AC voltage GSM signal break into voice channel via Installation Some of wire except power supply is grounded You hear different acoustic shocks and feedbacks in the ...

Page 26: ...25 Bad volume level from lift cabin Incorrect microphone installation must be placed directly behind the panel hole or low level of microphone amplification via capture Installation ...

Page 27: ...all numbers which are used by unit The numbers which are dialled during button press are saved under names MASTER1 to MASTER7 eventually TEST1 to TEST8 Further are saved numbers PARGLWV and PARRL1 Under them are saved all unit parameters except SMS texts and voice messages Numeral after MASTER TEST name determine order of numbers dialing Of course save as much MASTERx TESTx numbers as you need for...

Page 28: ...ESTx numbers must be stored on the SIM card as first When you need change default parameters save numbers under names PARGLWV and PARRL1 For sending SMS from input IN1 names PORTCLOSE eventually PORTOPEN If a SMS messages are stored on the SIM card delete them Switch off mobile phone and out SIM card Note When working with a mobile phone follow the instructions for the type of mobile phone When yo...

Page 29: ...hen this number is saved the GLWV call him when MASTER4 number is unreachable busy or doesn t pick up call a long time this number is allowed make incoming calls MASTER6 when this number is saved the GLWV call him when MASTER5 number is unreachable busy or doesn t pick up call a long time this number is allowed make incoming calls MASTER7 when this number is saved the GLWV call him when MASTER6 nu...

Page 30: ...me this number is allowed make incoming calls this number is allowed make remote SMS configuration TEST7 when this number is saved the GLWV call him when TEST6 number is unreachable busy or doesn t pick up call a long time this number is allowed make incoming calls this number is allowed make remote SMS configuration TEST8 when this number is saved the GLWV call him when TEST7 number is unreachabl...

Page 31: ...tic connection test possibility of all bits combination for example 7 all tests activated 6 SMS and acoustic connection test F closing time of IN2 port necessary to start blocking 0 9 s GG blocking duration after open IN2 port 00 99 s H duration of button press for emergency call activation 0 9 s I waiting time for connection before dialling next number in order 1 9 x 10s J 0 3 Extended mode 0 off...

Page 32: ...t must stay in system at least 1 number as TESTx otherwise you cant program remotely you will have to use again command INIT via Table upper SMS are always written by BIG LETTERS SMS body includes words split by spaces First word express what will be done READ read name phone number or parameter CLR clear name phone number INIT initialize SET set relay RESET reset e g ECALL START start of procedur...

Page 33: ...status ON OFF READ TEST time and result of the test service call READ IMEI IMEI number for the approximate calculation of the TEST call delay CLR NAME Phone number erasing for NAME INIT TEST1 420cc c Initiating first GLWV setting parameters is possible program from number TEST1 420xxxxx SET REL1 ON Relay 1 close SET REL1 OFF Relay 1 open SET REL1 ON xx Relay 1 close for xx minutes xx 00 99 RESET E...

Page 34: ...rt is opened xx 00 99 s 01 WRITE PAR ACALL x Time x sec Of button press to make emergency call x 0 9 s 3 WRITE PAR WCALL xx time xx sec Waiting for connection before dialling next number in order xx 10 20 30 90 sec 20 WRITE PAR EXMODE x Extended mode x 0 off emergency mode and service mode x 1 on emergency mode service mode is off x 2 on service mode emergency mode is off 0 WRITE PAR RL1MOD x Rela...

Page 35: ...g number for SMS PORT OPEN Input open CAL AT CSQ GSM signal strength measurement CAL AT CPBR x Identification of number saved under position x CAL AT CCLK time Time setting in GLWV on time format time yy MM dd hh mm ss zz yy year 00 99 MM month 01 12 dd day 01 31 hh hours 00 23 mm minutes 00 59 ss seconds 00 59 zz time zone 47 48 hours Note When you desire program by SMS some GLWV parameters we re...

Page 36: ...er just adjusted parameters SMS example for setting GLWV parameters WRITE PAR VOLIN 1 VOLOUT 4 BLOCK 60 RL1MOD 1 GLWVanswer WRITE PAR VOLIN 1 BLOCK 60 Next examples Read of service visits number and date of last one READ SERVICES GLWV answer READ SERVICES 14 09 23 3 Where 14 09 23 is date 23 9 2014 and 3 is number of visits Relay close attempt in incorrect mode different from determined for contro...

Page 37: ...3 BATTERY 3960mV POWER 15 5V TIME 14 09 23 09 21 55 OPER T Mobile TEMP 26C SERV 14 09 23 126 INP 0 BLOCK 0 REL OFF ECALL AKUSTIC PASS Single parameter saving setting of waiting time for dialing next number 30 seconds WRITE PAR WCALL 30 GLWV answer WRITE PAR WCALL 30 ...

Page 38: ...ght up red LED USB 4 The USB driver can be automatically installed on the PC the first time it is used Keep your computer connected to the Internet so that you can download the driver 5 Run GLWVset program and select correct COM port 6 Program checks connection with GLWV After verification of connection will go to appropriate status of GLWV in this case go to status ON when shows GSM signal streng...

Page 39: ... switch moving to position OFF programming mode To monitor operation do not click You stop GLWV operation Green point identify serial line operation After connection with GLWV will be shown indication of motherboard voltage backup ACU After connection with GLWV will be shown indication of GSM signal strength After connection with GLWV will be shown indication of GLWV power supply In ON mode are so...

Page 40: ...39 After click to Support button is possible monitor GLWV operation when operation is not stop by button ON OFF Saving of report log from monitor to file for service purposes report sending ...

Page 41: ...ded from GLWV to the program EMERGENCY folder It is designed for emergency call parameters programming Closing time of IN2 port necessary to start of call blocking Press time for call activation EMERGENCY button Field to programm up 7 phone numbers for emergency call Blocking duration after IN2 port is open Speaker loudness Microphone sensitivity Control of Emergency alarm mode Waiting for connect...

Page 42: ...gramming Period of TEST function activation Movement of TESTs start from midnight Field to programm up 7 phone numbers of service call Test type setting Number for sending status SMS Waiting for connection before dialling next number in order Overtake from EMERGENCY ...

Page 43: ...er Phone book on the SIM checking numbers on the SIM for example GSM operator service status SERVICE etc Name position Phone number position Add line over line with cursor Erase line with cursor Search for inserted name ...

Page 44: ...SMS when IN1 port is open and closed When number is not filled SMS is not send Information about mode which influence using type of IN1 port SMS Items connected to relay closing time Relay closing time Voltage on limit level for decision acceptable low voltage ...

Page 45: ...essages and SMS contents CAUTION Not expert manipulation might caused unfunctionally of GLWV which is not responsibility of producer Commands or files list which will be recorded to GLWV manually editable List reading from PC List erasing Command execution and files sending to GLWV The action procedure is monitor by scale in bargraf ...

Page 46: ... 3 by click on Send button send files into GLWV procedure is indicated by growing scale in bargraf Note When you desire load the same list again for example after test and adjustment some files via follow you cant read the list again Contrarily when you desire load other list you must erase previous list otherwise lists are added together to execute more actions simultaneously via follow Erasing o...

Page 47: ...l be recorded to GLWV 6 We have to also provide erasing useless file ecall wav from GLWV Click again on button Load List and add one more file DELMessageECALL ifo in report is now list of recorded wav files supplemented by command for erasing file ecall wav 7 By click on button Send send files and command to erasing together to GLWV process is indicated by growing scale in bargraf Lift identificat...

Page 48: ... from according your requests Text must be without diacritics hitch and comma line spacing Enter The length is maximal 100 letters per one SMS 3 Click on button Load List and in directory select file SMSsupgrade ifo in recorded list will appear file of text messages 4 By click on Send button send file to GLWV process is indicated by growing scale in bargraf Upgrade fw GLWV 1 ZIP file with upgrade ...

Page 49: ... by bargraf via picture Therefore all positions on SIM card are progressively rewrite or erase it can také a couple of minutes according size of SIM card The end of operation is signalled by bargraf disappearing In OFF mode you can record all parameters to GLWV program anytime You can save or record parameters from PC GLWV will start again by switching to mode ON click on button Program will send ...

Page 50: ...ics positioning and volume setting The device stores the measured values as reference The device then during the acoustic path test compares these calibration values with the ranks newly in the measured test The comparison then evaluates the momentary deviation of the acoustic path parameters Calibration can only be started by SMS START ACALIB If a outgoing call has been made just before the calib...

Page 51: ...d 2 sec 1 to 5x short flash Flashing long flash short space Fast short flashing Permanent light Green LED REL Permanent light Not light Green LED IN1 IN2 Permanent light Not light Yellow LED ACT Permanent light Alternating flashing 1 sec green red Green LED CON Permanent light Red LED ARM Permanent light Red LED USB Permanent light ...

Page 52: ...ferent operator messages has GLWV own operation signals Trill up medium height tone High tone once after number dialing 2x trill Low tone error Beep by high tone with growing number of beeps Message ready wav Device in stand by mode Message stop wav Device in programming mode Message atest wav Sound test 1 2 3 4 End ...

Page 53: ... Message error wav ERROR Message nocall wav Connection failed Try again later please Message nolog wav Not log in GSM network Message nosim wav SIM card is not inserted Message pin wav Incorrect PIN Message test wav Attention This is a test connection Message timeout wav Attention The connection will be terminated Message wait wav Wait please to connection ...

Page 54: ...t store unit with ACU when ACUswitch is not in down position By self discharging might be ACU destroyed without warranty Inserting of ACU Use ACU approved by producer only Li Ion 18650 2000 2600mAh Keep polarity Never insert ACU in wrong polarity You can damage whole unit CAUTION on polarity of ACU is isolated hat from ACU The switch must be in the bottom position ...

Page 55: ...y We not provide warranty for damages caused by incorrect progress of ACU connection When ACU polarity is incorrect flash or light permanently red LED When all is correct then connect power supply and move switch to up position By this connect ACU into system ...

Page 56: ...55 Simplest connection ReMicA1 without optical signalling signalling in lift cabin by voice only power supply from lift system 8 30V Emergency button M R G S R G M S ...

Page 57: ...out optical signalling The schematic is the same as on the previous page Because it is completely identical the other examples that will be for ReMicA1 also apply to ReMicAS1 8 30V Emergency button M R G S R G M S ReMicAS1 terminal block ...

Page 58: ...57 Basic connection ReMicA1 with signalling bulbs power supply from lift system M R G S R G M S SW 8 30V Emergency button 12 24V 12 24V Jumpers closed ReMicA1 I1 I2 ...

Page 59: ...58 Basic connection ReMicA1 with signalling LEDs power supply from lift system M R G S R G M S SW 8 30V Emergency button 12 24V Jumpers opened 12 24V ReMicA1 I1 I2 ...

Page 60: ... Basic connection ReMicA1 with controlling of signalling logic inputs table in the cab to ground power supply from lift system M R G S R G M S SW 8 30V Emergency button Jumpers closed TABLE ReMicA1 I1 I2 ...

Page 61: ...ic connection ReMicL1 with signalling LEDs power supply from lift system ReMicL1 is intended only for direct LED connection M R G S R G M S SW 8 30V Emergency button Upper jumpers closed in trio ReMicL I1 I2 ...

Page 62: ...61 Basic connection with main power supply M R G S R G M S SW Main PSU 230 Vac 12Vdc Emergency button 12 24V 12 24V ReMicA1 I1 I2 ...

Page 63: ...with external ACU and charger Of course the device may include a built in backup battery see technical parameters M R G S R G M S SW Main Pb ACU charger 12V 700mA Emergency button 12 24V 12 24V ReMicA1 Pb ACU 12V 7 Ah I1 I2 ...

Page 64: ...63 Connection example for lift cabin machine room PREPOJ communication 8 30V M R G S R G M S SW ReMicA1 ReMicL1 I1 I2 M R G S M G R S PREPOJ Machine room communication Lift cabin communication 12 24V ...

Page 65: ...tion lift cabin shaft machine room totally possible connect 3pcs ReMic 8 30V M R G S R G M S SW I1 I2 M R G S M G R S PREPOJ Machine room communication Lift cabin communication ReMicA1 L1 12 24V R G M S Lift shaft communication 2x ReMicB ...

Page 66: ...mple of activation by galvanically isolated screws of switch 12V ReMicA L 1 connection to bell or siren SW 12V 12V DC Siren connection example in relay mode button Relay closed during button press 12 24V according siren ...

Page 67: ...66 Connection example of service button with pilot light of confirmation Pilot light will lights up when GLWV receive service button press and send SMS 12 24V according pilot light Button service ...

Page 68: ...hatech spol s r o Jeremenkova 88 140 00 Praha 4 tel 42 0 272 103 335 fax 42 0 272 103 334 e mail info alphatech cz internet http www alphatech cz naše souřadnice GPS WGS 84 N 50 02 35 5 E 14 25 42 0 24 8 2020 ...