background image

Installation Instructions

4 / 11 / 2022 / Rev 1

1170 N Red Gum St, Anaheim, CA 92806

©  ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.

info@aluz.lighting

aluz.lighting

866.ALUZ.LTG | 714.535.7900

A8 Series 

|

 

LED Tape

ZIZA

 

Standard

(A8-ZIZA-STN)

Page 1 of 12

Overview

READ ENTIRE GUIDE BEFORE STARTING INSTALLATION

Important Notice:

 

Verify correct luminaire was received with correct 

color temperature, voltage, and wattage before cutting or installing. 

ALUZ will not be responsible if incorrect luminaire is installed.

GENERAL FEATURES

Applications

Accent, Decorative, Surface, Recess, Pendant Lighting

Lens

Clear, 50% Semi-Frosted, or 100% Frosted

Viewing Angle

120°

Length

Built to Order (+/- 1/8” Tolerance)

Construction

Aluminum Extrusion

Weight

0.241 lbs per foot

Mounting

Mounting Channel or Mounting Clips (Sold Separately)

Listing

Dry, Wet, or IP67 Location

UL2108, CSA C22.2 #9

UL8750, CSA250

Driver

Remote (Sold Separately)

Temperature 

Ratings

Operating / Startup: -20° to 48°C (-4° to 120°F)

Storage: -40° to 76°C (-40° to 170°F)

Installation Link

END VIEW / DIMENSIONS

.64”

.50”

ELECTRICAL

Dimming

DMX

Maximum Run

(Class 1 Applications)

21’ 

(5.5W)

26’ 

(4.5W)

Maximum Run

(Class 2 Applications)

17’ 

(5.5W)

21’ 

(4.5W)

Luminaire Voltage

24VDC

PRODUCT INFORMATION

• For accent, decorative, surface, recessed, or pendant lighting.

• 24 Volts DC for easy and safe installation.

• Long life, energy effi cient LEDs.

• Can be ordered to specifi c lengths for when exact dimensions are known

  

Example:

 10 x 10’6”

• Plug and light system.

• Lead wires are typically 36” long and exit on one end.

ELECTRICAL REQUIREMENTS

• Luminaires require a 24 Volt DC remote driver.

• To calculate driver size, determine Watts per Foot.

  

Example:

 4.5W per Foot

• Determine Length in Feet.

  

Example:

 10’

• Calculate Load: Multiply Watts per Foot x Length in Feet

  

Example:

 4.5W x 10’= 45W

• Choose a driver from catalog.

  

Example:

 60 Watt Driver

• Determine maximum driver distance using Maximum Wire Length Table on

  drivers page.

  

Example:

 45 watts is between 40W and 60W. Using #14 wire, maximum distance

  is 37’ from driver to fi rst LED.

• Electric Hammer Drill

• 14.4 to 28 Volt Cordless Drill         

• Phillips Bits  

• Utility Knife

• Electrical Cord   

               

• Marker 

• Wire Stripper

• Long Nose Pliers

• Drill Bits - Concrete or Wood

• Electrical Three Ways

• Safety Glasses

• Measuring Tape

• Laser Line or Chalk Line 

             

INSTALLATION TOOLS REQUIRED

INSTALLATION RECOMMENDATIONS

•  Luminaires must be mechanically attached directly to mounting surface using 

mounting clips, channels, or other appropriate means.

  Refer to installation step by step pages for details.

•  Conduit raceway should be sleeved at one end for low voltage wires going to driver.

Summary of Contents for A8 Series

Page 1: ...W 21 4 5W Luminaire Voltage 24VDC PRODUCT INFORMATION For accent decorative surface recessed or pendant lighting 24 Volts DC for easy and safe installation Long life energy efficient LEDs Can be ordered to specific lengths for when exact dimensions are known Example 10 x 10 6 Plug and light system Lead wires are typically 36 long and exit on one end ELECTRICAL REQUIREMENTS Luminaires require a 24 Vo...

Page 2: ... feed through wires inside LED Lightstrip will void warranty Ground Fault Circuit Interrupter GFCI protections should be provided on circuits or outlets when LED Lightstrip is used for outdoor applications Surge protector must be set up for electrical power system to avoid damaging LED Lightstrip lighting system Do not connect wires together follow provided wiring diagrams Do not cut wire while en...

Page 3: ...s 001 A DMX Control System by others must be used to operate the lighting The last driver in a daisy chain sequence must be terminated Driver load not to exceed 100W For best dimming performance it is recommended to load drivers to a minimum of 50 50W and a maximum of 80 80W Up to 28 drivers may be daisy chained together using shielded cable specified for DMX wiring Ensure DIP Switch 1 is set to ON...

Page 4: ...FF Color SHOW 00 20 SPEED 99 99 INTENSITY 0 255 DISPLAY OFF Show Standalone Operation should only be used when a control system is not present to control the lighting not recommended DMX ADDRESS NETWORK RESOLUTION DMX TERMINATION NETWORK SETUP INTERPOLATION 1 512 8 BT 16 BT YES NO AUTO MANU OFF VID COLR WHIT GLOW DISPLAY OFF NO ADDRESS ADDRESS SET NO OF BALLASTS DISPLAY OFF Set DMX Address Set DAL...

Page 5: ...ER WIRE SOLDER COVERING WIRE AND PADS WELLER 0 50 SOLDER WIRE SOLDER COVERING WIRE AND PADS COVER CONNECTIONS WITH SILICONE SOLDERING GUIDE 1 Cut lightstrip to desired length Include both sets of solder pads by cutting to the left or right of designated markings allowing more space for soldering 2 Prepare wires by stripping 1 8 from the end of each wire then tin the tips of the wire with solder Ap...

Page 6: ...line and pre drill using an appropriate drill bit for surface material and screw size Typical screw size is 8 32 x 1 Note Allow 1 4 clearance on each side of mounting clip to account for lateral expansion Only install mounting clips on flat even surfaces 3 Space mounting clips evenly throughout the run Example 20 Run 2 Use 1 mounting clip every 2 rounded up Use a minimum of 2 mounting clips per lu...

Page 7: ... disconnects between luminaires or solder connectors using the steps from Application Guidelines 3 Screw extrusions to surface using countersink screws Note Ensure extrusions are aligned Misalignment will prevent lens from snapping in 7 Perform a continuity test before connecting luminaire to power source 2 Lay extrusions along chalk line and drill at least 3 countersink holes per extrusion Drill ...

Page 8: ...n 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropriate for installation environment before installing Do not install luminair...

Page 9: ...g clips Mark location where each mounting clip will be installed along reference line 3 Lay mounting clips along reference line and pre drill using an appropriate drill bit for surface and screw size Recommendation 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips will be...

Page 10: ...ht leaks test before connecting luminaire to power source 7 Perform a continuity test before connecting luminaire to power source 1 Measure area where luminaire will be installed Use a laser line to create a reference line along installation area ensuring consistent alignment of mounting channels 3 Screw extrusions to surface using countersink screws Note Ensure extrusions are aligned Misalignment...

Page 11: ... 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropriate for installation environment before installing Do not install luminaires with inadequate number o...

Page 12: ...positive and negative copper pads to touch 1 Turn power off before beginning Verify power is turned off by using a non contact circuit tester Touch the probe of the tester to positive wire of the power source The tester will light up if an electrical current is detected 2 Setup your tester First insert the black probe lead into the COM jack then insert the red probe lead into the VΩ jack Metal Fla...

Reviews: