background image

ELECTRONIC VACUUM CLEANER

OPERATION MANUAL

SERIES

Important

Read this operation manual before operating the cleaner.

Only individuals who have read this manual and fully understood its contents
may operate the cleaner.

Follow all operation and maintenance instructions and carry out the daily and
periodic inspections as specified in this manual.

Observe all applicable laws and regulations regarding the installation and
maintenance of the cleaner.

Summary of Contents for Cleam Mac V-Sigma

Page 1: ...dividuals who have read this manual and fully understood its contents may operate the cleaner Follow all operation and maintenance instructions and carry out the daily and periodic inspections as spec...

Page 2: ...loss of eyesight injury burn high low temperature electric shock bone frac ture poisoning etc which leave aftereffect or require to receive regular outpatient treatment to cure completely Injury means...

Page 3: ...ce the consumable parts as specified in this manual Any modification repair or equipment transfer performed by a third party or personnel not authorized by AMANO Natural disasters or calamities such a...

Page 4: ...Start 14 Usage Precautions 15 Never Run the Cleaner with the Hose Blocked 16 Never Operate under Excessive Load 16 Central Cleaning Setup 17 Maintenance 18 Shaking Out the Filter 18 Emptying the Buck...

Page 5: ...outlet Incorrect voltage or multiple loads may result in fire or electric shock Never insert or remove the power cable while your hand is wet Doing so may result in electric shock Do not allow the po...

Page 6: ...fire Switch off the power immediately if the machine begins to emit smoke produce a strange sound or odor overheat or vibrate abnormally Continued operation may lead to electric shock or fire Switch o...

Page 7: ...oved or the cleaner while bucket is attached Bucket Collects the vacuumed dust You must periodically remove the bucket to empty out the dust Clamp The 2 clamps hold the bucket in place Wheel Supports...

Page 8: ...the unit is standing by for a filter shaking operation Blinking at 0 2 second intervals indicates that the unit is performing a filter shaking operation ON green Fan operating This is used for shaking...

Page 9: ...of the product Keep the operating temperature between 0 and 40 C When moving the product on a sloping surface be careful not to topple it Do not attempt to move the product on a steep slope which can...

Page 10: ...k area fits correctly onto the bucket 9 Pull the two clamps on the cleaner over the clamp hooks on the bucket Fasten the clamps to lock the bucket in place The pipes and the intake port are packaged i...

Page 11: ...occur due to failure to connect the ground there is a risk of fire or electric shock There is also a risk that static electricity could cause damage to the equipment or faulty operation Cautions All w...

Page 12: ...he product is ordered with the selector switch for remote control the selector switch and signal wire inlet are installed on the electrical control door To operate a standard model using remote contro...

Page 13: ...ame Pattern A Pattern B Pattern C Pattern D OFF ON OFF ON OFF OFF ON ON Selector switch Lever 1 2 Yes Yes Yes No Yes No No No Description Remote Local Remote Local Remote Local Enables the operation o...

Page 14: ...sed for remote control must be below DC10V 10mA 1 Turn OFF the power supply at the source To ensure safety turn OFF the power supply at the source 2 Open the electrical control door Remove the two scr...

Page 15: ...mally open type switch for all patterns The filter shaking movement takes place while the filter shaking switch is being pressed and the contacts are closed For patterns B C Selector switch 1 For patt...

Page 16: ...so may result in fire or explosion If fire or explosion occurs within the machine proceed as follows Immediately cut off the power Apply a suitable extinguishing agent Do not open the tank lid and the...

Page 17: ...his time the cleaner performs a self diagnosis power supply confirmation and phase detection and will not turn on even if the switch is pressed The phases of the wires are reversed if the Power Lamp b...

Page 18: ...be removed to ensure safety 2 Swap the wiring connections inside the plug Remove the plug s metal fitting and expose the inside of the plug as shown Disconnect any two of the three leads but not the g...

Page 19: ...ust to enter the blower leading to potentially significant problems Periodically check the filter s condi tion and be sure that is shaken clean as necessary Do not step on the hose Stepping on the hos...

Page 20: ...ose or other area reduces the air flow Air intake must not fall below approximately 1 0m3 min Never Operate under Excessive Load Vacuuming in too much air causes the load on the motor to ex ceed its r...

Page 21: ...o offers secondary air intake tubes that can prevent complete blockage Installation of the secondary tube will protect against complete air blockage in the event that the system is accidentally operat...

Page 22: ...ic shock Cautions Always wear gloves when inspecting or changing the filter and other parts Not wearing gloves may result in an injury or accident Always unplug the power cable from the wall outlet be...

Page 23: ...king 1 Once power is supplied automatic filter shaking is per formed one minute after the cleaner is stopped for the first time 2 Subsequent automatic filter shaking is performed at the following inte...

Page 24: ...tor Press the OFF switch to shut down the blower motor Then wait 1 minute for the motor to stop before proceeding 2 Remove the filter and shake it out Remove the filter cover lift the filter frame and...

Page 25: ...shakeout does not start until the blower motor has been switched off for 1 minute 2 Release the clamps Release the two clamps holding the bucket to the cleaner unit 3 Remove the bucket Lift the clean...

Page 26: ...then lift the pack out of the bucket and discard it 3 Insert a new dust pack Spread the pack evenly over the inside of the bucket Press it pack firmly against the equalizing tube so that the tube pier...

Page 27: ...an automatic shakeout model wait for au tomatic shakeout to finish Note that shakeout does not start until the blower motor has been off for 1 minute 3 Disconnect the power cord from the wall outlet...

Page 28: ...ower motor Wait 1 minute for the blower motor to stop 2 Shake out the filter Remove the filter cover lift the filter frame and shake out firmly to remove the adhered dust from the inside of the fil te...

Page 29: ...motor Wait 1 minute for the blower motor to stop 2 Shake out the filter Remove the filter cover lift the filter frame and shake out firmly to remove the adhered dust from the inside of the fil ter 3 R...

Page 30: ...move the plates 3 Install the new brush Set the new brush in place then screw in the fastening plates with the 8 screws Belt Inspection and Adjustment If abnormal noise or vibration is produced near t...

Page 31: ...urn the nut below the blower base to the left to narrow the pulley gap and decrease the belt tension Turn the nut to the right to widen the pulley gap and in crease the belt tension Repeat the adjustm...

Page 32: ...ing has deteriorated In this case replace it immediately 1 Removing the Rear Panel Remove the 6 screws to remove the rear panel 2 Inspecting the Motor Packing Inspect the motor packing for deteriorati...

Page 33: ...ace the cord or check the power source 3 Wait for the power to come back on 4 Replace the printed board 1 Unplug the power cord and change the wire connections in the plug 1 Unplug the power cord and...

Page 34: ...or connection If the sheath is broken if the core is exposed stop operation immedi ately and replace the cord Check the plug area to make sure it is free of damage and deformation If the cord is conne...

Page 35: ...lt VJA 6063 or VJA 6064 Use VJA 6063 for 50Hz or VJA 6064 for 60Hz For V 5 and V 7 Part Name Part No Remarks Span bond filter VJC 250170 For general dust Fine fil filter VJC 251170 For fine and ultra...

Page 36: ...ed on nameplate 3 7kW 5 5kW 0 3 3 6 0 0 3 3 6 4 22060 19120 9806 25990 22550 9806 10m 4 core Molded filter Cloth filter Molded filter Cloth filter 2 6m2 1 2m2 2 6m2 1 2m2 Automatic manual Manual Autom...

Page 37: ...33 Unit mm External Dimensions...

Page 38: ...34 Wiring Diagrams Manual shaking Automatic shaking 3 phase 200V 3 phase 200V Connect to 4 for V 7 Fan motor Connect to 4 for V 7 Fan motor Shaking motor M2 motor condenser...

Page 39: ...OFF 3 Shaking ON OFF 4 COM 5 Remote control enabled 6 Connect to 4 for V 7 Fan motor Shaking motor M2 motor condenser Remote control terminals 3 phase 200V Connection to 3 is not necessary when the sh...

Page 40: ...ium AMANO KOREA CORPORATION Woolim E Biz Center 2 4F 407 Yangpyeong Dong 3Ga 16 Yeongdeungpo Gu Seoul Korea 150 103 AMANO INTERNATIONAL TRADING SHANGHAI CO LTD Room No 901 Zhongdian Mansion 1029 Nanqu...