background image

 

 

Summary of Contents for Amber Power C210

Page 1: ......

Page 2: ...ant alerts for vibration over speed etc External power supply cut off alarm Two way talk Door status detection Multiple analog digital I Os Battery charging protection Specifications Frequency GSM 850 900 1800 1900MHz GPRS Class 12 TCP IP Operating Voltage 9 36VDC 300mA Location Time Cold Start 35s Hot Start 2s Storage 32Mb 32Mb Battery 450mAh Location Accuracy 10 meters Dimension 80 9 L 55 8 W 23...

Page 3: ...icator Blue I 0 1s ON 0 1s OFF Searching GPS signal Steady on GPS is fixed OFF Sleep or not work GSM LED Indicator Green 0 1s ON 0 1s OFF GSM initializing 0 1s ON 2sOFF Receive GSM signal normally Steady on Connected to GPRS network OFF No GSM signal ...

Page 4: ...dy on Device is charging OFF Low battery Power off Flash in a loop Device is in defense status 3 Wire Connection Wire Definition Li ne Color Description Definition 1 MIC SPK 3 5 mm 2 GND Ground 3 SVDC OUT Controllable 4 TX Transmit data 5 RX Receive data 6 Green IN1 Configurable positive input negative input ...

Page 5: ...lack SOS SOS Negative 11 White SOS SOS Positive 12 Purple ADC Detect 0 3 30V voltage 13 Orange ACC ACC 14 Black GND Ground 15 Red PW Power 9 36V Wiring Diagram Notice Purple line ADC of terminal connects to analog signals line like voltage of external device analog temperature sensor fuel sensor Voltage detected by analog signal ranges from 0 30Vdc ...

Page 6: ...line 85 and thin yellow line 86 Thin white line 85 connects to the positive side of battery 12V while thin yellow line 86 connects to the device relay control There is an oil pump in the vehicle Cut off the positive line The positive side of oil pump connects to the dose end of relay Thick green line 87a and the other side connects to relay s common green thick 30 Notice 12V relay is standard The ...

Page 7: ...in battery will be charged If battery is OFF battery can t be charged The device will be power off if no external power supply 5 Main Functions 1 SOS In emergent case press SOS for 3 seconds to activate SOS alarm Then the device will send SOSSMS to preset SOS numbers and then dial the numbers in a loop for 3 times until the call is picked up Alarm message will also send to platform See command lis...

Page 8: ...ctricity cut off When vehicle is stolen oil electricity cut off command can be sent by platform APP or SMS Notice 1 Make sure ACC is correctly connected 2 When ACC is OFF command will be executed immediately 3 When ACC is ON but GPS is not fixed command will be postponed 4 When ACC is ON GPS is fixed command will be executed when vehicle speed is less than 20km h If you want to cut off restore oil...

Page 9: ... is open signal level of door is power voltage when door is closed signal level of door is OV 12 Analog Signal The device can measure car battery s voltage and upload It to platform APP in fixed time based on your needs Purple line ADC of device extended port can receive analog signal like voltage of external device analog temperature sensor and fuel sensor Voltage range of analog input is 0 30Vdc...

Page 10: ... install the APP in designated website APP store or Google Play store 7 Common Command List Edit SMS command in the right column to the device SIM number to achieve respective function as below 1 Device status STATUS 2 Device coordinate WHERE 3 Location URL URL 4 Check version VERSION 5 Network setting GPRSSET 6 Check parameter PARAM 7 APN setting APN apnname E g APN internet APN apn name user pwd...

Page 11: ...ement alarm setting default OFF 1 MOVING ON R M R 100 1000 Displacement radius unit meter M 0 2 Alert way O GPRS 1 SMS GPRS 2 GPRS SMS CALL E g MOVING ON 200 2 2 MOVING OFF 15 Set center number Set center number CENTER A mobile number Delete center number CENTER D 16 Power oil control RELAY A A 0 1 O restore petrol 1 cut off petrol Default value 0 E g RELAY 1 17 Restart RESET Device restart 20 sec...

Page 12: ...icators sleep Check power supply Press side key to activate indicators No update of vehicle s location No GPS positioning Test the device again Change installation place Warranty instructions and service 1 The warranty is valid only when the warranty card is properly completed and upon presentation of the proof of purchase consisting of original invoice indicating the date of purchase model and se...

Page 13: ...the FCCP art 15 19 15 21 and 15 105 rules for this EUT the instructions or operation manual furnished the users hall include the following or similar statement placed in a prominent location in the text of the manual FCC Warning Th is device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device...

Page 14: ...lation If this equipment does cause harmful interference to radio or television reception which can be determined by Reorient or relocate the receiving antenna lncrease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help N OTE2 Any...

Reviews: