INSTALLATION INSTRUCTIONS
1. Remove the cover by removing (2) tamper resistant screws using security wrench supplied.
IMPORTANT: Save security wrench.
2. Dryers should be placed at least 2 feet (61cm) apart and at least 12” (30cm) from washbasin.
Do not install dryer over washbasin. Automatic dryers should be at least 18” (46cm) above
any projection which may interfere with the operation of the automatic sensor.
Hold the backplate to the wall at the suggested mounting height. Measure
from bottom edge of
backplate
to the floor (
Ref. Dimension “A” Fig. 1
)
DR-N Hand Dryer
42” (107cm)
40”(102cm)
30-40” (76-102cm)
34” (86cm)
DR-TNH Hair Dryer
72” (183cm)
68”(173cm)
46-68”(117-173cm)
52”(132cm)
3. Mark the locations of the four mounting holes and the conduit entrance location on the wall.
(The conduit entrance is the proper hole diameter for 1/2 inch (13mm) conduit.)
4. Fasten the backplate to the wall where previously marked.
RECOMMENDATION:
Wood wall
- No. 16 (M8) wood screws, 2 3/4” (70mm) long
Cement or brick
- 1/4” (M6) stud expansion bolts, 3” (76mm) long
Hollow wall
- 1/4” (M6) toggle bolts, length depends on wall thickness
5. Run service wire to the dryer location and connect to the terminal block. IMPORTANT: All
units must be supplied with 3 wire service. Use No. 12 wire or larger, as required by local
electrical code. The ground wire must be connected to the dryer backplate. Unit must be
installed by a qualified licensed electrician.
CONNeCT TO A DeDICATeD CIRCUIT NOT TO exCeeD 20 AmpS.
Dryers located in shower rooms or other wet locations should be equipped with ground fault Interrupter(s).
6.
Carefully
replace the cover using (2) tamper-resistant screws supplied. Be careful not to
damage circuit board or sensor. Apply a bead of caulk around edge of cover to wall.
AmeRICAN DRYeR LImITeD WARRANTY - “DR”
All parts of the
DR
series are warranted to the original consumer purchaser to be free
from defects in material and workmanship for a period of ten (10) years from the date
of purchase from manufacturer, in the U.S.A. Outside of the U.S.A., two (2) years. On
automatic models, the electronic sensor is warranted for five (5) years. Outside of the
U.S.A., two (2) years. We will replace FREE OF CHARGE, during the warranty period, any
warranted part which proves defective in material and/or workmanship under normal
installation, use, and service, excluding normal wear. Replacement parts can be obtained
by returning the part, TRANSPORTATION CHARGES PREPAID. You must notify factory
prior to returning part or dryer. Any damage to this dryer as a result of misuse, abuse,
neglect, accident, improper installation, unauthorized repairs, or any other use violative
of instructions furnished by us, WILL VOID THIS LIMITED WARRANTY.
THIS LIMITED
WARRANTY IS THE SOLE WARRANTY ON OUR PRODUCTS, AND WE DISCLAIM AND
EXCLUDE ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. OUR LIABILITY SHALL NOT EXCEED IN ANY EVENT THE REPLACEMENT
OR SALE PRICE OF THE ALLEGEDLY NONCONFORMING PRODUCT AND SHALL
EXCLUDE LABOR CHARGES. TO THE EXTENT PERMITTED BY LAW WE SHALL NOT
BE LIABLE FOR ANY LOSS, COST, EXPENSE, OR INCIDENTAL OR CONSEQUENTIAL
DAMAGES OF ANY KIND, WHETHER BASED UPON WARRANTY (EXPRESS OR
IMPLIED), CONTRACT, NEGLIGENCE OR STRICT LIABILITY AND ARISING IN ANY
WAY IN CONNECTION WITH THE DESIGN, MANUFACTURE, SALE, USE OR REPAIR
OF THE PRODUCT.
OWNER’S MANUAL
“DR”
HAND AND HAiR DRYERS
F
or
I
nstallatIon
or
s
ervIce
a
ssIstance
P
lease
c
all
(734) 421-2400
or
email: sales@americandryer.com
I
mPortant
:
H
ave
M
odel
& S
erial
N
o
. r
eady
m
odel
#
______
s
erIal
#
______
meN
WOmeN
DISABLeD
CHILDReN
(depends on age)
DISCONNECT POWER BEFORE INSTALLING
DESUNA LA ELECTRICIDAD ANTES DE HACER REPARACIONES
WARNING:
AMERICAN DRYER, INC.
33067 INDUSTRIAL ROAD, LIVONIA, MI 48150, U.S.A.
Telephone (734) 421-2400 • Fax (734) 421-5580
www.americandryer.com • Email: sales@americandryer.com
Revised May 2011
FLOOR
“A”
DO NOT MOUNT
TOP SIDE DOWN
Figure 1
ALL MODELS
10 13/16
(274mm)
2 3/4
(70mm)
9 1/2
(241mm)
5/8
(17mm)
9 1/16
(230mm)
7 7/16
(189mm)
5/8
(17mm)
1 5/16
(33mm)
9 1/8
(232mm)
7/8
(22mm)
IN WALL
CONDUIT
ENTRANCE
7/8
(22mm)
SURFACE
CONDUIT
ENTRANCE
TOP