background image

 
 
 

 

 
 
 

 
 
 
 
 
 

© Copyright 2005, American Fibertek, Inc. 1213JD 

Instruction Manual 

 

MTX-8810C-SL 

MRX-8810C-SL  

Eight Channel Video Multiplexer 

with Bi-directional Sensornet Data 

Summary of Contents for MTX-8810C-SL

Page 1: ... Copyright 2005 American Fibertek Inc 1213JD Instruction Manual MTX 8810C SL MRX 8810C SL Eight Channel Video Multiplexer with Bi directional Sensornet Data ...

Page 2: ...ctional Description 3 Installation 3 Power Source 4 Power Connection 4 Input Output Connections 4 Data Configuration 5 MTX 8810C SL Status LED Indicators 6 MRX 8810C SL Status LED Indicators 7 Warranty 8 Service Information 8 ...

Page 3: ...espondingly the MRX 8810C SL receiver converts the optical signal to eight independent video output signals along with the data signals The 8810C SL Series units operate on 9 um singlemode fiber Refer to the data sheets for detailed performance specifications The individual units may be configured for rack mounting or wall mounting depending upon the position of the included mounting hardware INST...

Page 4: ...UT CONNECTIONS The fiber optic connection is made via a FC PC connector located at the back of the unit Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used Video input and output connections are located on the rear of the unit A BNC connector is provided for each channel The video inputs are connected to an appropriate 75Ω baseband video source such as a c...

Page 5: ...of switch 5 these switches must remain in the positions shown below to properly transmit Sensornet data Switch 5 is used to apply a 120Ω termination resistor across the data I O connections These units are shipped with the data input output connections unterminated Move switch 5 to the down position if termination is required for your application ...

Page 6: ...t panel DATA LEDs are listed below DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX Sensornet Tx Sensornet Rx Tx Carrier Detect Rx Carrier Detect OLI A bi color LED indicator monitors the optical input power of the data signal that is being received at the MTX 8810C SL from the MRX 8810C SL AC power and optical input status associated with this LED are summarized below Optical Level Indicator AC Power Stat...

Page 7: ...r Detect Rx Carrier Detect OLI 1 A bi color LED indicator monitors the power of the optical input signal that is being received at the MRX 8810C SL from video channels one through four of the MTX 8810C SL AC power and optical input status associated with this LED are summarized below Please note that data is sent as a subcarrier on channel one s video signal Optical Level Indicator AC Power Status...

Page 8: ...R THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In any event American Fibertek will not be responsible or liable for contingent consequential or incidental damages No agreement or understanding expressed or implied except as set forth in this warranty...

Reviews: