background image

Rev. 2, July 2003

 EXCELLENCE IN MAGNETICS AND CRYOGENICS

American Magnetics, Inc.

P.O. Box 2509, 112 Flint Road, Oak Ridge, TN 37831-2509

 

Phone: (865) 482-1056

Fax: (865) 482-5472

 

Internet: http://www.americanmagnetics.com
E-Mail: support@americanmagnetics.com

AMI

AMI MODEL 4Q05100PS 

4-QUADRANT POWER SUPPLY

INSTALLATION, OPERATION, AND 

MAINTENANCE INSTRUCTIONS

I.

INTRODUCTION

The AMI Model 4Q05100PS is designed to provide a compact, 4-quadrant capability for 
AMI power supply systems. The Model 4Q05100PS is designed to operate with the AMI 
Model 420 Power Supply Programmer.

II. SPECIFICATIONS

________________________________________________________________________________

AC Input Voltage:  . . . . . . . . . . . . . . . 100-120 VAC or 200-240 VAC ±10%

1

AC Input Frequency: . . . . . . . . . . . . . 47 to 63 Hz

DC Output Current/Compliance:  . . . ±100 A @ ±4.0 V, ±80 A @ ±4.7 V, ±60 A @ ±5.0 V

Power-Absorbing Mode

2

 Rating: . . . . 325 VA max. @ 25°C, linearly derated to 

 

295 VA max. @ 40°C

Output Overvoltage Protection:  . . . . ±6 VDC (nominal)

Ambient Temperature Rating . . . . . . 0 to 40°C

352*5$0,1

Control Signal:

 . . . . . .  −

10 to +10 VDC

3

Output Voltage Noise: . . . . . . . . . . . . 0.6 mV RMS into 20 MHz BW (typical)

 

10 mV p-p into 20 MHz BW (typical)

 

75 mV p-p into 20 MHz BW (maximum)

Torque Limit on Current Terminals:  50 in-lbs.
________________________________________________________________________________

1

 Input voltage range is selectable via an internal switch.

2

 The supply is in absorbing mode when the polarity of the output voltage is opposite the 

polarity of the current flow.

3

 Gain of 0.5 is applied to the voltage output of the unit.

Summary of Contents for 4Q05100PS

Page 1: ...______________ AC Input Voltage 100 120 VAC or 200 240 VAC 10 1 AC Input Frequency 47 to 63 Hz DC Output Current Compliance 100 A 4 0 V 80 A 4 7 V 60 A 5 0 V Power Absorbing Mode2 Rating 325 VA max 25 C linearly derated to 295 VA max 40 C Output Overvoltage Protection 6 VDC nominal Ambient Temperature Rating 0 to 40 C 352 5 0 1 Control Signal 10 to 10 VDC3 Output Voltage Noise 0 6 mV RMS into 20 M...

Page 2: ... gases Doing so could result in a life threatening explosion WARNING Do not modify this instrument in any way If component replacement is required return the instrument to AMI facilities as described in the Troubleshooting section of this manual WARNING If this instrument is used in a manner not specified in this manual the protection provided by the design manufacture and documentation of the ins...

Page 3: ...em The figure on the following page illustrates the interconnects for an AMI Model 4Q05100PS power supply Connect the cabling in the following manner CAUTION Do not overtighten the nuts on the current lugs of the Model 4Q05100PS maximum torque is 50 in lbs Overtightening can result in damage to the terminals CAUTION Do not overtighten the nuts on Model 420 See Model 420 manual for torque specifica...

Page 4: ... 625 5 92 7 48 1 2 56 0 5 1 0 1 7 6 1 2 5 71 8 6 6 725 6 7 16 1 9 0 9 9 Superconducting Magnet Model 420 Rear Panel 2 3 4 5 6 8 9 1 92 7 0 21752 5 287387 20081 7 216 6 6 16 0 5 1 0 1 7 6 1 2 5 71 8 6 1387 32 5 RS 232 J8 S11 ON 9 9 6 1625 AMI Model 13x Rear Panel 7 AMI Model 4Q 05100 Four Quadrant Supply Rear Panel 1 System interconnect diagram for the AMI Model 4Q 05100 power supply ...

Page 5: ...DC input which controls the output voltage of the unit using a gain factor of 0 5 WARNING Exercise caution near the supply output terminals on the rear of the unit when operating a magnet Metallic objects shorted across the terminals may conduct large DC currents which are capable of melting the object and causing severe burns D The 287387 1 7 switch functions as an emergency override The output o...

Page 6: ...I are warranted to be free of defects in materials and workmanship and to perform as specified for a period of one year from date of shipment In the event of a failure occurring during normal use AMI at its option will repair or replace all products or components that fail under warranty and such repair or replacement shall constitute a fulfillment of all AMI liabilities with respect to its produc...