INSTALLATION INSTRUCTIONS
752352-100 REV. H
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
ELLISSE BUILT-IN™
SERIES WHIRLPOOL
2703.XXXW
2705.XXXW
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
T H A N K Y O U . . .
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any
shipping damage. If such damage is found, report it to
your vendor immediately.
After inspection and during installation, protect the bath
from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit
and check for leaks.
If a whirlpool, do not make modifications to the whirlpool
system or remove pump from factory mounting. This
could adversely affect the safety and performance of the
whirlpool and void the warranty. Do not handle or move
the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided
with the bath and must be ordered separately. Framing
and enclosing materials are provided by others. Check
for availability of optional American Standard wall tiling
bead (required for recess installations).
Protect all finished surfaces of the whirlpool during
construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping har-
ness at any time.
List of Optional Components (not included):
• Apron Kit*
• Safe-T-Heater 9075.120*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 or 20 amp GFCI
Outlet
• Cement, Plaster,
Grout
GENERAL SPECIFICATIONS FOR 2703/5 WHIRLPOOL
60 x 32 x 21-1/2 In. (1524 x 813 x 546mm)
141 Lbs. (63 Kg.)
643 Lbs. (292 Kg.)
60 Gal. (277 L)
50 Gal. (189 L)
44-1/2 X 20 In. (1130 mm X 508 mm)
58 X 26-1/4 In. (1473 mm X 667 mm)
14-1/2 In. (368 mm)
48 Lbs./Sq.Ft. (231 Kgs./Sq.m)
20.8
35.3
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.6 HP, 9.7 AMPS, 120V.
2.1 HP, 15.6 AMPS, 120V.
SYSTEM I PUMP
SYSTEM II PUMP
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
1524mm
(60)
PROVIDE ACCESS
TO PUMP FOR SERVICING
ON ALL INSTALLATIONS
229mm
(9)
387mm
(15-1/4)
51mm
(2)
813mm
(32)
533mm
(21)
1-1/2 N.P.T.
THREADS
1-1/2 O.D.
TAILPIECE
38mm
(1-1/2)
83mm
(3-1/4)
C/L OF DRAIN
OUTLET
FINISHED
WALL LINE
C/L OF
SUPPLIES
ON/OFF SWITCH
WATER RETENTION
FLANGE (3) SIDES
305mm
(12) OPT.
102mm
(4)
95mm
(3-3/4)
546mm
(21-1/2)
ROUGH
FLOOR
PUMP
ALT. PUMP
LOCATION
19mm
(3/4)
LEVELING
STRINGER
NOT FOR
SUPPORT
ROUGH
FLOOR
WATER
RETENTION
FLANGE
UNDERSIDE
OF DECK
FINISHED WALL
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
INTEGRAL
FEET
C/L OF
OVERFLOW
TOP
OF
DECK
38mm
(1-1/2)
1651-1981mm
(65-78)
OPTIONAL
229x305mm
(9x12) FLOOR
CUTOUT
51mm
(2)
SEE FITTING
SPECS FOR
DIMENSION
■
SAFE-T-HEATER
REMOVABLE BLANK