751753-100 Rev. L
© AS America, Inc. 2009
All product names listed herein are trademarks
of AS America, Inc. unless otherwise noted.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
THANK YOU...
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
*
see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 20 amp GFCI
Outlet
• Cement, Plaster,
Grout
GENERAL SPECIFICATIONS FOR 2709 WHIRLPOOL
69-1/4 x 38-1/2 x 19-3/4 In.(1759 x 978 x 502mm)
107 Lbs. (49 Kg.)
640 Lbs. (291 Kg.)
64 Gal. (243 L)
53 Gal. (201 L)
45 x 23 In. (1143 x 584mm)
63 x 32 In. (1600 x 813mm)
13 In. (330mm)
35 Lbs./Sq.Ft. (166 Kgs./Sq.m)
25.6
49.4
WHIRLPOOL ELECTRICAL SPECIFICATIONS
2.1 HPR, 15.6 AMPS, 120V.
SYSTEM II PUMP
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
1759 mm
(69-1/4)
ROUGH
FLOOR
1-1/2 O.D.
TAILPIECE
OUTLINE OF
CUTOUT
240 mm
(9-7/16)
978 mm
(38-1/2)
464mm
(18-1/4)
INTEGRAL
FEET
SUPPORT
86mm
(3-3/8)
38mm
(1-1/2)
489mm
(19-1/4)
76mm
(3)
CLOF DRAIN
OUTLET
502mm
(19-3/4 )
1-1/2 N.P.T.M.
THREADS
35mm
(1-3/8)
305mm(12) X 229mm(9)
CUTOUT IN FLOOR FOR DRAIN
98mm
(3-7/8)
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
ON/OFF
SWITCH
PUMP
SAFE-T-HEATER
REMOVABLE BLANK
INSTALLATION INSTRUCTIONS
HIGH GLOSS ACRYLIC
ELLISSE OVAL™
2709.XXXW SERIES WHIRLPOOL / BATHING POOL