background image

INSTRUCTIONS FOR USE

Before starting the appliance, please read this operating manual carefully.

AEP60BL

AEP90BL

Angled Extractor

Summary of Contents for AEP60BL

Page 1: ...INSTRUCTIONS FOR USE Before starting the appliance please read this operating manual carefully AEP60BL AEP90BL Angled Extractor ...

Page 2: ...r extractor 7 Care and maintenance 9 Changing the charcoal filter 10 LED lighting 11 Electrical information 12 Troubleshooting 14 Mounting your extractor 15 Installation 16 Installation diagrams 17 Installation diagrams 18 Energy efficiency information 19 CONTENTS ...

Page 3: ...xperience or knowledge about it unless they have had supervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel Appliance information Please enter the details on the appliance rating plate below for reference to assist Amica Cu...

Page 4: ...s for the environment and health It also enables the constituent materials to be recovered saving both energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled dustbin Please note Under no circumstances should the extractor be connected to any gas ventilation system flue system or hot air ducting system Do not ven...

Page 5: ...lume ventilation available and cleanliness of the filters Ducting For best performance and lowest noise output we recommend the use of 125mm ducting Lesser diameter ducting may be used but this will reduce performance and increase the noise of the extractor Wherever possible use the rigid circular pipe which has a smooth interior rather than the expanding concertina type ducting The lengths of the...

Page 6: ...plied are suitable for most installations It is the responsibility of the installer to ensure that the fixings are suitable for the ceiling type in the property Cover any hob or surface below the area in which the extractor is to be installed so that no damage befalls it DUCTING ...

Page 7: ...trol Panel A Light button B Speed level buttons C Power off button To switch the extractor light on or off Press button A To switch on the extractor or to change the speed at any time when the extractor is running Press the relevant B button for the first second or third speed level as required To switch the extractor off Press button C USING YOUR EXTRACTOR Fig 1 B A C ...

Page 8: ...e cleaner Any abrasive cleaner including Cif will scratch the surface and could erase the control panel markings You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth for example a micro fibre cloth Cleaning the grease filter The grease filter should be kept clean to minimise the risk of fire At least once a ...

Page 9: ...ng the removal process Please note Cleaning the grease filter in the dishwasher may lead to discolouration This is normal and does not constitute a fault with the appliance Changing the charcoal filter re circulating mode only To ensure best performance of your extractor you should replace the charcoal filter every four to six months depending on use To attach the charcoal filter Remove the grease...

Page 10: ...aceable The lighting is designed for use during cooking and not for general room illumination Extended use of the lights will reduce the lifespan of the bulbs In the event of a problem with the lighting please contact Amica Customer Care for assistance Contact details are on page 13 ...

Page 11: ...ype into the fuse cover 3 Replace fuse cover Important Do not use the appliance without the fuse cover in position As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured GREEN and YELLOW must be connected to the terminal which is marked with letter E or by the...

Page 12: ...marked with the letter L or coloured RED If in doubt regarding the electrical connection of this appliance consult a qualified electrician Do not shorten the supply cable the appliance may require removing for servicing N B Ensure that the plug socket is situated in an easily accessible place If the power supply cord is damaged it must replaced by an Amica authorised agent ELECTRICAL INFORMATION ...

Page 13: ...t This is normal and the extractor will work again once the motor has cooled sufficiently If your extractor is not working 1 Check that the mains supply has not been switched off 2 Check that the fuse in the plug has not blown 3 Check that the control panel is clean and free from grease Contact Amica Customer Care A Amica The CDA Group Building Harby Road Langar Nottinghamshire NG13 9HY T UK 01949...

Page 14: ...al requirement and may lead to your hob being disconnected from the gas supply and the installation being reported under RIDDOR Note The height should be measured from the top of the burners IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm The width of any hob must not be greater than the width of the extractor i...

Page 15: ... designed nor intended to be touched and may contain sharp or rough edges that could cause injury Always wear adequate Personal Protective Equipment PPE Ducting and ventilation For best performance and lowest noise output we recommend the use of 125mm ducting 100mm ducting may be used but this will reduce performance and increase the noise of the extractor Note We recommend that you seek the help ...

Page 16: ...LONGER SCREWS MAY CAUSE DAMAGE TO THE INTERNAL WIRING WHICH WILL NOT BE COVERED BY THE WARRANTY Tools required Fig 8 Fig 9 Fig 10 Fig 11 Mark out wall as required see Fig 7 Drill six mounting holes Fit wall fixings and top screws Ensure that any fixings you use are appropriate for the wall type INSTALLATION DIAGRAMS ...

Page 17: ...17 Fit the ducting adaptor Fig 12 Fig 13 Fig 14 Fix ducting and seal joints Mount the chimney Adjust and secure the chimney Fig 15 INSTALLATION DIAGRAMS ...

Page 18: ...ncy 19 0 Energy Efficiency Index 68 0 B Measured airflow at Best Efficiency Point 186 5m h Measured Pressure at Best Efficiency Point 326Pa Maximum airflow 350m h Measured electric power at Best Efficiency Point 89 0W Normal lighting power 4W Average illumination of lighting system in the cooking surface 450Lux Measure power consumption in standby Measure power consumption off mode 0 Sound power l...

Page 19: ...19 ...

Page 20: ...lding Harby Road Langar Nottinghamshire NG13 9HY For service or queries please contact The Customer Care Department For the UK please call 01949 862 012 For Ireland please call 1 800 535556 Email customer care cda eu 21 05 2019 ...