background image

Installation Guide

CB-TP17 

Rough-In Box for 17" Wall/Flush Mount Touch Panels

Overview

Wall Mount panels (NXDs) are contained within a metallic outer housing (back 
box). This back box is 

not removed

 when installing the NXD into a Rough-In 

Box (CB-TP17). The back box is 

only

 removed to gain access for the 

replacement of the Compact Flash component or upgrade to the VESA housing.

The CB-TP17 Rough-In Box is an optional metallic box that is secured onto a 
beam in a pre-wall setting (where no walls or present). Installation procedures 
and configurations can vary.

Specifications 

WARNING: 

INSTALLER, LEAVE A GAP BETWEEN THE STUD AND ROUGH-

IN BOX TO ACCOMMODATE THE DRYWALL/SHEETROCK. 
This gap allows the installation of the drywall/sheetrock after the CB-TP17 has 
been mounted onto the beams. The stud notching and Rough-In Box installation 
must be done prior to any wall installation.

Note: 

The most important thing to remember when mounting this Rough-In Box 

is that the mounting tabs must be mounted flush against the outside of the 
sheetrock. This step determines whether or not the mounting stud is notched

 

(cutout-out to fit the Rough-In Box).

Pre-Wall Installation of the CP-TP17 Rough-In Box

1.

Measure the distance between the inside of the two selected stud beams. 
Most beams have a distance of about 14" to 16". This is too narrow to 
accommodate the 17.072" (43.36 cm) wide CB-TP17 Rough-In Box.

2.

Determine whether one or both of the selected stud beams must be 
notched (FIG. 2). The determining factor is the flush alignment of the 
mounting tabs along the outside of the post-wall sheetrock.

3.

Cutout the notched beam using a height of 13.554" (34.43 cm) (as shown 
in FIG. 2) and a depth 

equal to the thickness of the drywall

.

Note: 

The determining factor in the depth of the cut into the beam is the 

thickness of the drywall. The mounting tabs MUST BE FLUSH against the 
drywall and therefore, the depth of the notch depends on that thickness.

4.

Insert one side of the Rough-In Box into the indention on the notched stud 
and rest the other side of the box against the opposite beam.

5.

Install and secure a shorter horizontal beam below the Rough-In Box. This 
beam acts to support the weight of the box from below and should be 
secured to both vertical beams (at the sides).

6.

Fasten the CB-TP17 to the 

Notched stud/beam

 through the stud fastening 

holes, located on the inside of the Rough-In Box (FIG. 3), by using either 
nails or screws.

7.

Insert a perpendicular block between the 

Non-Notched stud/beam

 and 

the Rough-In Box. This block acts as a bridge to secure the stud/beam to 
the CB-TP17 along the stud fastening holes located inside of the box.

8.

Secure the perpendicular block to the 

Non-Notched stud/beam

 (FIG. 3) 

by using either nails or screws.

9.

Fasten the CB-TP17 to the 

block 

through the stud fastening holes, located 

on the inside of the Rough-In Box (FIG. 3), by using either nails or screws.

10. Remove any necessary wiring knockouts from the (optional) Rough-In Box 

(CB-TP17) (FIG. 3) where the necessary cables are threaded through for 
connection to the touch panel.   

11. Thread the incoming RJ-45, Ethernet, and any other audio/video wiring 

through the knockouts (use of the top or bottom knockouts are 
recommended with this installation). 

12. Install the drywall/sheetrock before inserting the main NXD unit into the 

CB-TP17.

Installing the 17" panel within a CB-TP17 Rough-In Box

The Rough-In Box must be mounted prior to continuing this section. Verify that 
all necessary cables have been threaded through the knockouts on the Rough-In 
Box and the connections have been tested prior to installation of the 17" panel.
1.

Remove the magnetic faceplate/bezel (

A

 in FIG. 1) from the main NXD unit 

(

B

 in FIG. 1) by gripping the faceplate and pulling with gentle outward force. 

2.

Verify the incoming RJ-45, Ethernet, and any other audio/video cables 
have been properly threaded through the wiring knockouts on the left of the 
Rough-In Box. Leave enough slack in the wiring to accommodate any 
re-positioning of the panel.

3.

Connect all data and power wiring connectors to their corresponding 
locations along the side of the (un-powered) NXD touch panel.

• Verify the terminal end of the power cable is not connected to a power 

supply before plugging in the 2-pin power connector.

• The USB connectors can be from either a USB extension cable, or a 

wireless USB RF transmitter.

Note: 

Don’t disconnect the connectors from the touch panel. The unit must be 

installed with the attached connectors before being inserted into the CB.

4.

Test the incoming wiring by connecting the panel connections to their 
terminal locations and applying power. Verify the panel is receiving power 
and functioning properly to prevent repetition of the installation.

5.

Disconnect the terminal end of the power cable from the connected PSN 
power supply.

6.

Carefully slide the main NXD unit (

B

 in FIG. 1) into the Rough-In Box, so 

the Mounting Tab lies flush against the Rough-In Box (

C

 in FIG. 1).

7.

Insert and secure four securing #8 flat-head Mounting Screws into their 
corresponding holes located along the sides of the NXD. 

These #8 screws 

are not included within the CB Installation Kit.

8.

Replace the magnet faceplate (

A

 in FIG. 1) back onto the main NXD unit. 

Make sure to align the Microphone, Light, and PIR Motion sensor locations 
to their respective openings on the front bezel/faceplate.

9.

Connect the terminal RJ-45, Ethernet, and any optional audio/video wiring 
to their respective locations (outside the Rough-In Box) on either the AVB 
breakout box, Ethernet port, or NetLinx Master. 

10. Reconnect the terminal power connector on the PSN and apply power.  

    

CB-TP17 (FG034-10) Specifications

 Dimensions (HWD) • 13.55" x 17.07" x 3.49" 

• 34.43 cm x 43.38 cm x 8.85 cm

Included 
Accessories

Rough-In Box Installation Kit (SA2001-02)
• 4 Phillips pan-head (#4-40 x 0.375 Black) screws (80-0115)
• 4 Phillips pan-head (#4-40 x 0.625 Black) screws (80-0118)

Certifications

• cTUVus Listed

FIG. 1  

Wall Mount panel installation configuration of a CB-TP17

B

 - Main NXD unit consists of 

C

 - Optional

Four #8 flat-head

(not included)

secure the NXD to

Stud

the touch panel and backbox housing

      CB-TP17

Support block

Mounting Tab

Do not

 use these

tabs to mount

the Rough-In Box

A - 

Faceplate

(bezel)

CB-TP17

Mounting Screws

All manuals and user guides at all-guides.com

all-guides.com

Reviews: