Installation Guide
CB-TP15
Rough-In Box for 15" Wall/Flush Mount Touch Panels
Overview
Wall Mount panels (NXDs) are contained within a metallic outer housing (back
box). This back box is
not removed
when installing the NXD into a CB-TP15
Rough-In Box. The back box is
only
removed to gain access for the replacement
of the Compact Flash component or upgrade to the VESA housing.
The CB-TP15 Rough-In Boxes are optional metallic boxes that are secured onto
stud beams prior to the installation of a solid surface. Installation procedures and
configurations can vary.
Specifications
WARNING
: INSTALLER, LEAVE A GAP BETWEEN THE STUD AND ROUGH-
IN BOX TO ACCOMMODATE THE DRYWALL/SHEETROCK.
This gap allows the installation of the drywall/sheetrock after the Rough-In Box
has been installed.
Note
: The most important thing to remember when mounting this Rough-In Box
is that the mounting tabs must be mounted flush against the outside of the
sheetrock.
Pre-Wall Installation of the CB-TP15 Rough-In Box
1.
Remove the rough-in box cover (
A
in FIG. 1) before installation of the
Rough-In Box (
B
). Note: the cover MUST be removed before drywall
installation. The cover may be reinstalled after drywall installation using
4-40 screws (not included)
2.
Fasten the CB-TP15 to a stud through the stud fastening holes, located on
the inside of the Rough-In Box (FIG. 2), by using either nails or screws.
3.
Remove any necessary wiring knockouts from the Rough-In Box (
C
in
FIG. 3) where the necessary cables are threaded through for connection to
the touch panel.
4.
Thread the incoming RJ-45, Ethernet, and any other audio/video wiring
through the knockouts.
5.
Install the drywall/sheetrock before inserting the main NXD unit into the
CB-TP15.
Installing a 15" NXD panel within a Rough-In Box
The Rough-In Box must be mounted prior to continuing this section. Verify that
all necessary cables have been threaded through the knockouts on the Rough-In
Box and the connections have been tested prior to installation of the touch panel.
1.
Remove the magnetic faceplate/bezel (
A
in FIG. 3) from the main NXD unit
(
B
in FIG. 3) by gripping the faceplate and pulling with gentle outward force.
2.
Verify that the incoming RJ-45, Ethernet, USB, and any other audio/video
cables have been properly threaded through the wiring knockouts (from
their terminal locations) on the Rough-In Box. Leave enough slack in the
wiring to accommodate any re-positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding
locations along the side of the (un-powered) NXD touch panel.
• Verify the terminal end of the power cable is not connected to a power
supply before plugging in the 2-pin power connector.
• The USB connectors can be from either a USB extension cable, or
a wireless USB RF transmitter.
Note
: Do NOT disconnect the connectors from the touch panel. The unit must be
installed with the attached connectors before being inserted into the Rough-In
Box.
4.
Test the incoming wiring by connecting the panel connections to their
terminal locations and applying power. Verify that the panel is receiving
power and functioning properly to prevent repetition of the installation.
5.
Disconnect the terminal end of the power cable from the connected PSN
power supply.
6.
Carefully slide the main NXD unit (
B
in FIG. 3) into the Rough-In Box, so
the Mounting Tab lies flush against the Rough-In Box (
C
in FIG. 3).
7.
Insert and secure the four securing #4-40 Mounting Screws into their
corresponding holes located along the sides of the NXD.
8.
Replace the magnet faceplate (
A
in FIG. 3) back onto the main NXD unit.
Make sure to align the Microphone, Light, and PIR Motion sensor locations
to their respective openings on the front bezel/faceplate.
9.
Connect the terminal RJ-45, Ethernet, and any optional audio/video wiring
to their respective locations (outside the Rough-In Box) on either the AVB
breakout box, Ethernet port, or NetLinx Master.
10. Reconnect the terminal power connector on the PSN and apply power.
CB-TP15 (FG032-10) Specifications
Dimensions (HWD) • 13.48" x 14.18" x 3.49"
• 34.24 cm x 36.00 cm x 8.85 cm
Included
Accessories
Rough-In Box Installation Kit (SA2001-02) (
one kit per CB
)
• 4 Phillips pan-head (#4-40 x 0.375 Black) screws (80-0115)
• 4 Phillips pan-head (#4-40 x 0.625 Black) screws (80-0118)
Certifications
• UL 508A
FIG. 1
CB-TP15 Rough-In Box with cover
4 locations to secure cover
after applying drywall
(8-32 x .25 screws)
4 locations to secure cover
after applying drywall
A