background image

In-Wall 7 Day Digital Timer Instruction Sheet

MADE IN CHINA

09/26/2022 MAPATIM-01

Timer # PATIM-01     

service@anconahome.com

  •  

1-800-350-4562

Rating:

General: 125 V ac, 60 Hz; 15 A, 1875W

Resistive: 125 V ac, 60 Hz; 15 A, 1875W

Tungsten (incandescent): 8 Amp, 125 VAC 1000 Watts

Ballast (fluorescent): 8 Amp, 125 VAC

Motor: 1/4 H.P., 125 VAC

SETTING THE CLOCK

1. Press and 

hold

 the CLOCK button to set time.

2. Press the DAY button until the display shows the current day.

3. Press the HOUR button until the display shows the current hour.

4. Press the MIN (Minute) button until the display shows the current minute.

SETTING PROGRAMS

  SET START TIME

1. a. Press the PROG (Program) button once. The display will look as 

  shown at the right.

  b. You will now set up the time in which you want your device turned ON.

  c. The number 1 in the lower left hand corner indicates that you are now 

  programming EVENT 1.

2. Press the DAY button repeatedly until the display shows the day(s) when you 

  want the timer to turn on. The options are:

  - All days of the week (MO, TU, WE, TH, FR, SA, SU)

  - Individual days of the week (MO, TU, WE, TH, FR, SA, or SU)

  - Weekdays only (MO, TU, WE, TH, FR)

  - Weekends only (SA, SU)

3. Press the HOUR and MIN (Minute) buttons to set the time when you want the 

  timer to turn on.

  SET STOP TIME

4. Press the PROG (Program) button again. The display reads as 

  shown at the right.

5. Repeat Steps 2 - 4 to set the OFF time for Event 1.

6. When programming is complete, press the CLK button to display the current time.

Things you should know about programming events

   - You can repeat the ON and OFF programming procedures for up to 7 events.

   - In order to use programmed times, 

MODE must be set to AUTO or RDM

   - ON / OFF button 

overrides

 the current programmed events.

OPERATING THE TIME SWITCH

Press the MODE button repeatedly to set the timer to Automatic, Random or Manual 

mode.

NOTE: 

For the time switch to run programmed events, it must be set to “AUTO” mode.

AUTO: runs all events automatically, according to the schedule you have set. The 

word “AUTO” appears in the display.

RDM (Random): runs all events in a RANDOM mode. This is a security feature in 

which ON and OFF times randomly differ ± 30 minutes of the programmed times, 

creating a more “lived-in” look. The word “RDM” appears in the display. 

OVERRIDING TIMER SETTINGS

The ON / OFF button overrides the current programmed events.

To override the current program (either ON or OFF), press the ON/OFF button.

NOTE: 

If the timer is not in “Manual” mode, it will obey the next programmed event. 

This allows the user to manually turn a light on and allow the program to shut the 

light back off at a preset time.    

RESETTING THE TIMER

In case of an operational failure of the timer, insert a thin non-conducting object (like

a wood toothpick) into the RESET orifice to clear all settings and restart.

If display screen is blank:

1. Connect timer to junction box.

2. Gently press the reset button until digital display appears.

3. Follow programming instructions.

*Works with CFL bulbs.

*This timer has been tested to work with standard compact fluorescent (CFL) bulbs. 

However, it will not control a CFL bulb that specifically states 

- Do not set up events out of order. Be sure to set up events in progressive order of 

  time (for example, 8:00pm ON, 9:00 pm ON, 10:00 pm ON — NOT 8:00 pm ON, 

  10:00 pm ON, 9:00 pm ON).

- Do not overlap event times (for example, 8:00 pm ON /12:00pm OFF, and 9:00 pm 

  ON / 11:00 pm OFF).

- Do not set ON / OFF events within 30 minutes or less from one another if you are 

  going to use the timer in the Random Mode.

  The Random Mode interval is ± 30 minutes from the programmed times, and 

  programs set too close together may overlap one another.

REVIEWING EVENTS PROGRAMMED

1. In the current time display, press the PROG (Program) button repeatedly to check 

  your settings.

2. When finished, press the CLK button to return the display to the time of day.

CLEARING (DELETING) AN EVENT

1. Press the PROG (Program) button as many times as necessary to locate the 

  setting you want to clear.

2. Press and hold the MODE button.

3. Press the PROG button to clear the setting.

4. When finished, press the CLK button to return the display to the time of day.

Black

White (Neutral)

Red

Ground / Green

A

B

D

C

B

1

2

3

4

A
B
C
D

C

D

B

8 : 00

1

PM

ON

MO TU WE TH FR

AUTO

12 : 00

1

AM

MO TU WE TH FR

OFF

AUTO

MODE button. Three kinds of settings can cause the timer to work in an unexpected 

way:

MANUAL: turns ON and OFF only when the user presses the ON or OFF button. 

The display is blank, showing neither RDM or AUTO. 

Remove wall plate and disconnect existing light switch, install junction box with a 

qualified electrician.

Make sure both “hot” (black or red) and neutral (white) wires are present in the 

junction box. If both wires are not present, additional wiring will be necessary 

before installation can be completed.

Connect red timer wire to wire from towel warmer fixture, using wire connector.

(   )

Connect black timer wire to the “hot” (usually black or red) wire in junction box

using wire connector. (   )

Expose white wire in junction box (or open splice) and strip 1/2 in. of insulation 

to both wires.

Connect all three white wires together (timer wire, junction box wires) using wire 

connector.

If the wall switch you are replacing had separate grounding conductors 

connected to the GREEN screw on the switch, make sure to connect these to 

the green wire from the timer with a wire connector. (   )

Check that all wire connections are secure.

Place all wires inside junction box.

Fit timer into junction box and install using two mounting screws (included).

Reconnect the electrical power

1. 
2. 

3.

 

4.

 

5.

 

6.
7. 

8.

9. 

10. 

11. 

1

2

(   )

3

4

NOTE: 

Timer installation is optional to towel warmer installation. Towel warmer 

fixtures DO NOT EXCEED RATED CAPACITY stated in this manual.

WARNING

While setting events, the timer may prematurely turn on the load, if you press the 

Reviews: