©  2020 Antari Lighting and Effects Ltd.   

www.antari.com

 

 

 

MB-55 MOBILE   
FOG MACHINE 

User Manual 

 

- ENGLISH 

 

 

 

 

 

 

 

 

 

 

 

 

©

 2020 Antari Lighting and Effects Ltd

Summary of Contents for MOBILE MB-55

Page 1: ...1 2020 Antari Lighting and Effects Ltd www antari com MB 55 MOBILE FOG MACHINE User Manual ENGLISH 2020 Antari Lighting and Effects Ltd ...

Page 2: ...2 2020 Antari Lighting and Effects Ltd www antari com ...

Page 3: ...tage does not match Disconnect the machine from AC power before servicing and when not in use This product is for indoor use only Do not expose to rain or moisture If fluid is spilled disconnect AC power and clean with a damp cloth If fluid is spilled onto electronic parts immediately unplug the machine and contact your local Antari dealer for advice No user serviceable and modifiable parts inside...

Page 4: ...case of eye contact or if fluid is swallowed immediately look for medical advice Unpacking and Inspection Immediately upon receiving the machine carefully unpack the carton check the content to ensure that all parts are present and have been received in good condition If any parts appear damaged or mishandled from shipping notify the shipper immediately and retain the packing material for inspecti...

Page 5: ...open space around the machine Step 2 Ensure that there are not any foreign objects in the threaded aerosol insert Align aerosol valve with threaded insert and carefully turn clockwise to fix into position Aerosol should be screwed in tightly to create an effective seal Power Switch Volume Control Knob LED Indicator Breaker Power Input Aerosol Compartment Wire Remote Socket ...

Page 6: ...idcator located in the back panel will turn solid green Now the machine is ready for operation Step 5 To start making fog press and hold the push button on handle bar release to stop Step 6 To adjust output volume rotate the knob located in back panel Turn counter clockwise to increase clockwise to decrease Step 7 To turn off the machine flip the power switch to OFF position Remove aerosol and pow...

Page 7: ...ng cycle the machine can generate smoke up to 45 minutes after disconnection The quality of fog must be carefully observed while operating disconnected to a main power source When smoke has become thin and blue indicates the temperature is getting low Reconnect machine to a main power source for heating process once it has reached working temperature it can be operated off disconnected again MB 55...

Page 8: ...stem to help avoid condensing the pump or heater It is recommended to run the machine on a monthly basis in order to achieve best performance and output condition Excessive dust liquid and dirt built up will degrade performance and cause overheating Breaker Reset Disconnect AC power before resetting the breaker Only replace fuse with same type and rating Step 1 Disconnect AC power Step 2 Flip brea...

Page 9: ...le fluid Ambient temp range Control Connection Optional accessories Dimension Weight US model AC 100 120V 50 60Hz 15A EU model AC 220 240V 50 60Hz 8A 1450W 7 5 minutes approx 110 ml min Antari FLP 700 aerosol 0 C 40 C 32 F 104 F Manual Wireless Optional IEC Power FCR 1 Wireless Remote L346 W152 H251 mm L13 62 W5 98 H9 88 inch 10 2 kg 22 49 lbs ...

Page 10: ...10 2020 Antari Lighting and Effects Ltd www antari com ...

Page 11: ...11 2020 Antari Lighting and Effects Ltd www antari com ...

Page 12: ...12 2020 Antari Lighting and Effects Ltd www antari com C08MB5500 ...