background image

RESET

h

m

s

RESET

START

GATE

RUN

OUT

K/P

H5CLR

Operating  voltage

Allowable  operating
voltage  range

Rated  frequency

Contact  rating

Reset time

Power  consumption

Life

Ambient  temperature

Ambient  humidity

Weight

Mechanical : 5,000,000 times  /  Electrical : 100,000 times

85 ~ 110% of  rated  operating  voltage

50 / 60Hz

MAX 0.1s

250VAC 5A (Resistive  load)

Approx.  2.5VA

-10

Д

+50

°

C

MAX 85% RH

Approx.  120g(H5CLR) / 150g(ASY-4DR)

AC/DC : 12

Д

48V / AC/DC : 100

Д

240V

NAMES AND FUNCTIONS OF FACEPLATE

SPECIFICATIONS

SETTING PROCEDURE

CONNECTION

P r o d u c t   i s   s u b j e c t   t o   c h a n g e   w i t h o u t   n o t i c e .

Upper display

Display PV values (current time, etc.) or  
setup items.

Lower display

Display SV values (set time, etc.) and  
other parameter values.

key :

Used for incrementing or decrementing  
numeric values.

Performing arithmetic shift operations and  
switches the display. Hold down for at least  
3 seconds to enter setting modes.

LEDs

RUN: Timing indicator
OUT: Control output indicator
K/P: Key protection indicator
RESET: Reset indicator
START: Start indicator
GATE: Gate indicator
h: Time unit display (Hour)
m: Time unit display (Minute)
s: Time unit display (Second)

     key :

Reset the output or save the value  
of setting.(after save than back to  
the operation mode)

key :

RESET

POWER ON

or

RESET

Reset

SPECIAL FUNCTION KEY

TIME RANGE

9.999s

Select the  
time range

Switch to output

 setting mode

OUTPUT MODE

Select 

output mode

Switch to count up/down 

setting mode

UP / DOWN MODE

Select count up  

or count down

Switch to input signal 

 time setting mode

INPUT SIGNAL TIME

Select input  

signal time

ϡ

 Mode A1,A2,A3,B1,B2,C,D and F are not available on ASY-4DR

ϭ

 and H5CLR-8 

OUTPUT TIME

Select  

output time

ϡ

 Not functionable on MODE C,D,E and F

ϡ

 Not available for ASY-4DR

ϭ

 and H5CLR-8

Switch to key protection level 

 setting mode

KEY PROTECTION LEVEL

Select key 

protection level

Switch to output contact 

 setting mode

OUTPUT CONTACT

Select output  

contact

ϡ

 Available on H5CLR-8/-11 and ASY-4DR

ϭʳ

type only

Switch to time range 

 setting mode

4

3

2

1

8

7

6

5

SOURCE

RESET

START

H5CLR-8 & ASY-4DR

ϭ

H5CLR-8G & ASY-4DRG

ϭ

H5CLR-11

H5CLR-11M

T.D. INST.

4

3

2

1

8

7

6

5

SOURCE

3

2

1

8

9

10

11

7

6

5

4

SOURCE

T.D. INST.

RESET

START

3

2

1

8

9

10

11

7

6

5

4

SOURCE

START

GATE

K / P

(Sensor)

Common (0V)

12 VDC(50 mA)

Load

(-)

(+)

RESET

H5CLR / ASY- 4DR 

MULTI-FUNCTION DIGITAL TIMER 

User's Manual

SAFETY  PRECAUTION

This manual uses the following symbols to ensure safe operation of this timer.

WARNING
CAUTION

Warnings are indicated when mishandling this product might result in death or serious injury 

Cautions are indicated when mishandling this product might result in minor injury to the user, 

to user.

or only physical damage to the timer.

Θ

Note this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has  

    been correctly wired before turning the power ON.

Θ

Before wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause  

    electric shock.

Θ

Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.

Θ

Do not disassemble the product. Doing so might cause electric shock or faulty operation.

Θ

Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage,  

    shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.

Θ

Firmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause fire.

WARNING

CAUTION

When using this product in applications  
that require particular safety or when  
using this product in important facilities,  
please pay attention to the safety of the  
overall system and equipment. Install fail- 
safe mechanisms, perform redundancy  
checks and periodic inspections and  
adopt other appropriate safety measures  
when it is necessary.

RESTRICTIONS ON USE

RESET

99.99s
999.9s

Count up
Count down

9999s

999.9m
9999m
999.9h
9999h

99m59s
99h59m

Hold
0.1s

20ms
1ms

0.5s

1s
5s
10s

15s
20s

Mode A
Mode A1
Mode A2
Mode A3

Lock function key
Lock reset key

2C
1A1C

Lock preset value key
Lock all key

Mode B
Mode B1
Mode B2
Mode C

Mode D
Mode E
Mode F

See reverse page for more details

Switch 

ON / OFF Key  

protection

PRESS FOR 3s

PRESS FOR 3s

Switch to input setting mode

RESET

Switch to input setting mode

(1)Stop

(2)Timing

PRESS  

FOR 3s

PRESS 

FOR 3s

or

Switch to input setting mode

RESET

RESET

Save and back to the  
operation mode

or

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

Switch to output time

 setting mode

RESET

Save and back to the 
operation mode

or

Reviews: