background image

Summary of Contents for SD-AZ03-01

Page 1: ......

Page 2: ...stions on installation compliance standards Building and plumbing codes may vary by location and we are not responsible for code compliance standards for your project and will not accept any returns 3 Prior to installation ensure that the installation surface is leveled and solid and will be able to support the total weight of the unit Also make sure the walls are at right angles Irregular install...

Page 3: ... o B 3 1 c p 1 e l d n a H 5 0 s c p 2 e g n i H 6 0 14 Wall bracket 4pcs 07 Wall anchor 6pcs 15 Bottom bracket 2pcs 08 Round head screw ST4 2 25 2pcs 16 4mm hex wrench 1pc NOTE Unpack your unit carefully and inspect it Lay it out and identify all parts using parts diagram and part list in your manual as a reference Before discarding the carton check for small hardware bags that tend to fall to th...

Page 4: ...line on the wall according to your Shower Enclosure model size Place the assembled Stationary glass panel 01 and Return glass panel 03 on the shower base butt them up against the wall and level them vertically See Fig 2 for details Note Make sure the Glass panels are absolutely vertical Fig 2 1 2 W1 W2 Model No W1 W2 SD AZ03 01BN 46 5 16 34 5 16 SD AZ03 01CH 46 5 16 34 5 16 ...

Page 5: ...ll bracket from the Glass panels and by placing it back to the outlined position mark the drilling holes on the wall Drill the holes in the wall using Ø 5 16 drill bit and insert the Wall anchors 07 for the Wall brackets Fasten the Wall brackets to the wall using the Big head screw ST4 2 55 09 See Fig 4 for details Fig 4 1 2 3 4 5 6 Ø 5 16 23 7 8 23 7 8 Glass panels must be on same level Glass pan...

Page 6: ...e the bracket s position on the wall Remove the Support bar and detach the wall bracket from it Place the wall bracket against its outlined position on the wall and mark the drilling hole Drill the hole using Ø 5 16 drill bit insert the Wall anchor 07 and fasten the wall bracket to the wall with the Big head Screw ST4 2 55 09 Attach the Support bar to the wall as shown on Fig 6 5 and tighten the s...

Page 7: ...tive bolts facing inside the shower Bring the Glass door 02 into the Shower base between the two stationary glasses Level up the Glass door next to the Stationary glass panel and fasten the hinges on the Glass Door Make sure the top edges of the Glass door and both Glass panels are aligned See Fig 8 and Fig 9 for details Fig 8 1 2 ...

Page 8: ...e surface of the shower base Cut the Flanged anti water strip 12 according to the measurements Press the cut strips on to the vertical edge of the Glass door Press the Side anti water strip 11 on the vertical edge of the Return glass panel 03 with the flange facing the door Press the Bottom anti water strip 13 on the bottom edge of the Glass door Install the Handle 05 to the Glass door See Fig 10 ...

Page 9: ...er base through the holes in the flange of the Bottom brackets using Ø 1 8 drill bit Fasten the bottom brackets with the Round head screw ST4 2 25 08 Cover the screw with the Decorative covers 10 See Fig 11 for details Fig 11 11 Apply the sealant along the connection of the stationary glasses with the walls and the Shower base See Fig 12 for details Fig 12 1 2 3 4 5 Ø1 8 ...

Page 10: ...g agents as this may scratch the surface Never use bristle brushes or abrasive sponges To ensure a long lasting hardware finish wipe off the metal parts after each use with a soft cloth Do not use abrasive cleaners or cleaning products containing ammonia bleach or acid If accidentally used rinse the surface as soon as possible to prevent finish peeling or corrosion After cleaning the shiny finishe...

Reviews: