background image

SEA Charging Station (SCS-8)

Operations Manual

Capewell Aerial Systems LLC

105 Nutmeg Road South

South Windsor, CT 06074

sales@capewell.com

P: 860.610.0700

www.capewell.com

Summary of Contents for SCS-8

Page 1: ...SEA Charging Station SCS 8 Operations Manual Capewell Aerial Systems LLC 105 Nutmeg Road South SouthWindsor CT 06074 sales capewell com P 860 610 0700 www capewell com ...

Page 2: ...in this document FNPT Female National Pipe Thread HP High Pressure PSI Pounds per Square Inch QD Quick Disconnect SEA Survival Egress Air Introduction The SCS 8 provides eight HP quick disconnects built in 6 000 PSI regulator over pressure relief valve and integrated flow restrictor to comply with US Navy fill rate standards of 250 500 PSI Min to prevent over heating of the cylinders and stress to...

Page 3: ...eft hand side 2 Test for leaks and verify pressure on the left hand red face pressure gauge USE CAUTION WHENEVER WORKING WITH HIGH PRESSURE COMPRESSED AIR 3 Adjust the regulator to 3000 PSI this will show on the blue faced gauge using the large black knob turning clockwise to increase the pressure and counterclockwise to reduce the pressure NOTE Both small black knobs should be closed at this time...

Page 4: ...rt of the SEA d Place the SEA into the cylinder holder tube b Install the male quick coupler fitting into the fill port until the o ring is fully seated this normally takes only finger pressure however you can use gentle pres sure with a wrench if desired c Pull the collar back on a female quick connector and insert the male until they are fully mated ...

Page 5: ...cylinders are full to 3000 psi as verified on the large gauge close the supply valve VALVES CAN BE DAMAGED BY EXCESS FORCE USE GENTLE FINGER PRESSURE ONLY NOTE You can adjust the flow faster there is a flow limiting device or slower with this same valve The integrated flow restrictor complies with the US Navy fill rate standards of 250 500 PSI Min 7 Vent the pressure from the fill hoses using the ...

Page 6: ... adapters 9 Unscrew the male part from the SEA fill port 11 Repeat steps 3 thru 8 as needed until all SEA s are filled to 3000 PSI 12 Once the SEA s are full relieve the pressure from the regulator by turning the large black knob counterclockwise 10 Reinstall the dust cap onto the fill port of the SEA 13 Turn off the high pressure air source to the fill manifold ...