INFORMATION,SETTINGS

swimming pool pump

MJB VSD

Summary of Contents for VIPOOL MJB VSD

Page 1: ...INFORMATION SETTINGS swimming pool pump MJB VSD...

Page 2: ...aulic connections P 5 3 B Electrical connections P 5 4 Control of the pump P 5 5 Operating of pump terminal box P 7 6 Operating of the remote box option P 10 6 B Additionnal functions THG et OME P 12...

Page 3: ...Visual control keypad with 5 colored keys 3 keys setting of the programmed speeds 2000 2400 and 2850 rpm pre Recorded and modulable from 1000 to 2850 rpm 1 key on and off 1 key to access the menu Time...

Page 4: ...t of a malfunction or failure please contact your nearest manufacturer s representative or the manufacturer s Technical Support Service Hot surface in the area around the motor This document contains...

Page 5: ...nnected so as to avoid the pump and pipe from being subjected to external stresses which could cause them to break irrespective of the assembly operations We recommend a vertical pipe length of approx...

Page 6: ...re cable GND common Black wire By connecting Black Brown speed 1 Black Green speed 2 Black White speed 3 Black Red Stop B Connecting the remote box Open the housing Pass the end of the cable into one...

Page 7: ...table priming time 0 to 10 minutes by 1 minute steps B User interface A Led screen displays the engine speed B SET key accesses the programming mode or resets the command C 1 key selects the fixed spe...

Page 8: ...ing step To stop the motor press the 0 key The Power LED flashes and the screen shows OFF Notice When the MJB VSD is used with the remote control unit the connection to the control unit must be shut d...

Page 9: ...d set between 0 off and 10 minutes priming F Reset To restore the factory settings to the motor hold down the SET button for about 15 seconds The motor stops and the three fixed speed LEDs light up Th...

Page 10: ...the program see next section Return Vary with the touchpad arrows Input screen in the program Select program 1 or 2 for settings Choose the arrows and press OK for validation Screens for choosing dail...

Page 11: ...shows day and hourly programmed speeds 0 to 12 hours and 12 to 24 hours per 1 hour interval in 1 hour O Off no filtration Speed 1 Speed 2 Speed 3 Programming speeds according to the hours on a weekly...

Page 12: ...set on the THG This allows the pump to start in V1 so as to prevent from freezing To do this rotate the scroll wheel to the position Lack of water option This option is composed of a 50 x 1 1 2 suppor...

Page 13: ...e event of an error the motor stops permanently Exception error Undervoltage insufficient voltage The motor restarts automatically as soon as the voltage becomes greater than 209 V for at least 6 seco...

Page 14: ...er bag s straining capability the item will not be repaired under warranty You can obtain additional flexible filter bags from your usual supplier Risk of injury to persons without the required qualif...

Page 15: ...tion direction three phase motor Check the condition of the couplings and seals along the suction pipe Invert 2 phases on the electricity supply Weak pump output Pressure loss in the suction Check the...

Page 16: ......