background image

 

This document and the information 

contained herein are the property of 

Appareo Systems, LLC and are 

confidential. They may not be disseminated 

or redistributed without the written 

permission of Appareo Systems, LLC 

APPAREO SYSTEMS, LLC 

FARGO, NORTH DAKOTA 58102 

Gateway Installation Manual 

DOCUMENT NUMBER 

600840-000038 

Document Type

 

Manual

 

Last Revised 

3/22/16 

REV 

1.2

 

Sheet 

1 of 9

 

 

Gateway Installation Manual 

GW03 

 

Summary of Contents for GW03

Page 1: ...dential They may not be disseminated or redistributed without the written permission of Appareo Systems LLC APPAREO SYSTEMS LLC FARGO NORTH DAKOTA 58102 Gateway Installation Manual DOCUMENT NUMBER 600840 000038 Document Type Manual Last Revised 3 22 16 REV 1 2 Sheet 1 of 9 Gateway Installation Manual GW03 ...

Page 2: ...vision Number Change Description Effective Date Inserted By 1 0 Initial Release 1 13 16 Lee Hinsz 1 1 Change 30 cm separation distance to 40 cm per check from NCEE test lab 2 3 16 Lee Hinsz 1 2 Addition of 60 cm for Canada per RSS 102 Addition of section 3 4 4 Condition of operation section and statement 3 22 16 Lee Hinsz ...

Page 3: ...RMATION 5 3 1 SPECIAL TOOLS REQUIRED 5 3 2 INSTALLATION INSTRUCTIONS OVERVIEW 6 3 3 PARTS LIST FOR INSTALLATION 6 3 4 HARDWARE COMPONENTS BACKGROUND 7 3 4 1 Electrical Characteristics 7 3 4 2 Weight and Balance Information 7 3 4 3 Equipment Dimensions 7 3 4 4 Conditions for operation 7 4 CONFIGURATION 8 4 1 Gateway System Separation Distances 8 4 2 Gateway System Separation Distance Illustration 9...

Page 4: ...r 600840 000038 Page 4 of 9 List of Figures Figure 1 Separation Distance 9 List of Tables Table 1 System Component Minimum Spacing 6 Table 2 Parts List for Installation 6 Table 3 Weight and Balance Information 7 Table 4 Equipment Dimensions 7 Table 5 Separation Distance 8 ...

Page 5: ...ts WAN designs with the additions of Bluetooth WIFI 433 MHz radio and Satcom interfaces 2 PURPOSE This Installation Manual is intended to inform installers and users of the proper placement configuration and distances between system components 3 GENERAL INFORMATION 3 1 SPECIAL TOOLS REQUIRED In addition to SAE standard and or metric wrenches sockets and screw drivers the following tool are require...

Page 6: ...pment such that the following distances are the minimum spacing between system components Table 1 System Component Minimum Spacing Operator Gateway Antenna Hub 1 Recommended minimum spacing between antenna hubs is 7 5 cm 40 cm USA 60 cm Canada 20 cm Antenna Hub 2 40 cm USA 60 cm Canada 20 cm Gateway 20 cm N A b Ensure the antennas have a ground place of 300 x 300 mm around them c Torque the antenn...

Page 7: ...ent dimensions where applicable Table 4 Equipment Dimensions Component Length mm Width mm Height mm Gateway 165 159 54 Antenna Hub 1 HCEL S2 0164A 01 124 3 80 3 80 3 Antenna Hub 2 HIRD S2 0146A 01 124 3 80 3 80 3 3 4 4 Conditions for FCC 15 231 a d operation IMPORTANT NOTICE This device can be configured to transmit on the 433 MHz frequency following the requirements of 47 CFR 15 231 Failure to ad...

Page 8: ...therwise in the above command replace the argument FCC_PERIODIC_15_231_E with FCC_APERIODIC_15_231_AD for 15 231 a d mode with the appropriate control message setup 4 CONFIGURATION With equipment installed final configuration must meet the minimum separation distance in Table 5 and Section 4 2 4 1 GATEWAY SYSTEM SEPARATION DISTANCES Operator Gateway Antenna Hub 1 2 Recommended minimum spacing betw...

Page 9: ...Y SYSTEM SEPARATION DISTANCE ILLUSTRATION Gateway and the following components must follow the distances in the following illustration to comply with FCC part 1 310 Operator Antenna Hub 1 Antenna Hub 2 Gateway 40 cm USA 60 cm Canada 20 cm 20 cm 20 cm Figure 1 Separation Distance 40 cm USA 60 cm Canada ...

Reviews: