background image

These instructions contain all the necessary fitting and operating instructions for your electric shower.

Care taken during the installation will provide a long, trouble free life from your shower.

INSTRUCTION GUIDE AND USER MANUAL

INSTANTANEOUS  ELECTRIC WATER HEATER - 

AQUAS REVA

AQUAS REVA FLEX SMART 9.5KW 

By

AQUABELLA SHOWER CO.,LTD.

IMPORTANT !

This Step-by-Step guide should be given to the customer

after installation and demonstration

Summary of Contents for AQUAS REVA FLEX

Page 1: ...during the installation will provide a long trouble free life from your shower INSTRUCTION GUIDE AND USER MANUAL INSTANTANEOUS ELECTRIC WATER HEATER AQUAS REVA AQUAS REVA FLEX SMART 9 5KW By AQUABELLA SHOWER CO LTD IMPORTANT This Step by Step guide should be given to the customer after installation and demonstration ...

Page 2: ...RTANT Before turning on the water supply to the shower unit the water supply pipe should be flushed out to remove debris After flushing the pipework ensure that the shower unit is positioned squarely on the wall and tighten the screws Tighten all plumbing connections and check the pipework for leaks IMPORTANT Ensure that the terminal block screws are fully tightened and that no cable insulation is...

Page 3: ...r supply with a minimum running pressure of 100kPa 15 lb sq in 1 Bar at a minimum flow rate of 8 litres per minute The maximum static pressure must be no greater than 500kPa 75 lb sq in 5 0 Bar All plumbing connections must be completed before making the electrical connections Always switch off at the isolating switch when not in use The flow rate of water passing through the shower unit determine...

Page 4: ...n off by other appliances e g From the mains feed to the W C This may cause a drop in pressure too low for the shower unit to work correctly An isolating valve must be fitted to comply with water regulations and for servicing purposes ISOLATING STOP TAP DOUBLE POLE HEATER SWITCH WALL MOUNTED IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS COLD WATER MAINS SUPPLY SEPARATE PERMANENTLY CONNECTED SUPPL...

Page 5: ...AQUAS REVA FLEX 9 5 KW RECOMMENDED INSTALLATION DIMENSIONS FOR ALL MODELS ...

Page 6: ...ATER CONNECTOR FREE FIX WALL BRACKET SET CW FIXINGS WALL BRACKET PACK FOR SLIDE BAR X 2 FREE FIX SHOWER TUBE 600 X 25MM WITH END CAPS FRONT LOADING SLIDER MECHANISM SMOOTH 1 5M PVC HOSE WITH ABS CONICAL NUTS HAND SHOWER VENTO 120 3F HANDSHOWER HEATER COVER COMPLETE WHITE HEATER COVER COMPLETE BLACK HEATER COVER COMPLETE CHROME SCREW FIXATION PACK FOR HEATER THERMAL CUT OFF DEVICE DIVERTOR VALVE AS...

Page 7: ...AQUAS REVA FLEX 9 5 KW MANUAL WATER HEATERS 3A 1 4 4 2 9 11 12 11 16 18 17 10 10 14 13 15 5 5 5 4 4 4 2 2 8 6 6 6 7 5 5 5 5 5 2 3 ...

Page 8: ...ASSEMBLY OF UPPER SHOWERING COMPONENTS 4 4 4 3A 2 3 4 ...

Page 9: ...9 5 5 5 2 8 6 6 6 7 5 5 5 5 5 ASSEMBLY OF LOWER SHOWERING COMPONENTS 1 2 ...

Page 10: ...water and electrical entry points PLUMBING CONNECTIONS POSITIONS SIDE LEFT SIDE RIGHT BOTTOM LEFT BOTTOM RIGHT REAR LEFT REAR RIGHT NOTE PLUMBING THE SHOWER UNIT MUST PROCEED WIRING The shower unit can be both plumbed and wired from 6 different A B ...

Page 11: ...ons to allow easy access when connecting the water supply Connect the mains water supply to the inlet of the shower unit using a 15mm copper stainless or plastic pipe with a 15mm compression elbow or 15mm push fit elbow Do not use excessive force when making the connection to the unit IMPORTANT To comply with water regulations building regulations or any specific local water company regulations an...

Page 12: ...le and out of reach of a person using a fixed bath or shower tray unless the switch is cord operated The wiring must be connected to the switch without the use of a plug or socket outlet The cable size required is determined by the kW rating of the shower and the distance between the shower and the consumer unit The table below will help you choose the correct cable for your installation but it wi...

Page 13: ... sheath of the supply cable must be stripped back to the minimum The use of connections within the unit or other points in the shower circuit to supply power to other equipment i e extractor fans pumps etc will invalidate the guarantee DO NOT switch on the electricity supply until the shower cover has been fitted NOTE The elements on UK models are to 240V specification and will give a lower kW rat...

Page 14: ... cover Turn the stabilizer valve spindle and volume handle fully clockwise until resistance is felt Fit cover into position and re fit cover fixation screws Stabilizer valve Divertor spindle When fitting the cover it is important to align the divertor spindle and volume control spindle inside the heater NOTE Before fitting the cover ensure that the 2 electrical wires are fitted correctly to the PC...

Page 15: ...tallation rotate the volume control handle clockwise until resistance is felt Connect the water and electricity supply IMPORTANT NOTE FOR THE INSTALLER 1 2 IMPORTANT Tum the Temperature control knob anticlockwise until the valve is fully open before switching on the unit This will ensure a fast fill up of the unit when the shower is first switched on IMPORTANT The shower unit must be full of water...

Page 16: ...ce the KW output down to 5 0 KW 6 To turn off the shower unit press the ON OFF button IMPORTANT NOTES The Higher the flow the temperature will decrease The Lower the flow the temperature will increase It is recommended that you start the shower with the volume handle in the fully anti clockwise cold position as this will provide maximum flow If a higher outlet temperature is required Rotate the vo...

Page 17: ...t nozzles in the Overhead Handshower Increase the flow by adjusting the temperature control knob to cooler setting Reduce the power setting Water pressure is at minimum requirement Check running pressure minimum of 1 0 bar Wait until pressure increases Shower temperature is set too high causing the hermal cut out to turn off the heating elements to reduce the water temperature Shower temperature c...

Page 18: ...stance please contact the installer or the local UK distributor from where the heater was purchased Ai0049 1 To break away scale deposit on a daily basis simply rub your thumb over the surface whilst the shower is running SHOWERHEAD CLEANING INSTRUCTIONS The showerhead should be cleaned periodically to remove limescale or debris which will reduce the performance of the shower The frequency of clea...

Reviews: