background image

bomba autoaspirante

para piscina

MONOFÁSICA

ASPIRE

Summary of Contents for ASPIRE 100

Page 1: ...bombaautoaspirante para piscina MONOF SICA ASPIRE...

Page 2: ...de seguridad Normas generales de seguridad Es imprescindible que tanto el instalador como el usuario lean las instrucciones antes de pasar al montaje y la puesta en marcha Esta simbolog a indica la p...

Page 3: ...o deben ser llevados a cabo por personas cualificadas y autorizadas y que stas hayan le do previamente de forma detenida las instrucciones de instalaci n y servicio Instalaci n y montaje GENERAL El mo...

Page 4: ...chapa caracter stica de la bomba con conexi n a tierra protegido con un interruptor diferencial RCD con una corriente de funcionamiento residual asignado que no exceda de 30 mA Ajustar convenientement...

Page 5: ...y conectar el motor Limpiar el cesto del prefiltro regularmente para evitar caidas de presi n No golpearlo durante el proceso de limpieza para evitar una posible rotura del cesto Si la bomba se para c...

Page 6: ...je err neo Comprobar el voltaje de la placa caracter stica y el de la red Prefiltro obstruido Limpiar el filtro P rdidas de carga en la instalaci n Evitar al m ximo que los elementos produzcan p rdida...

Page 7: ...pa 1 10 Tuerca tapa 1 11 Llave tapa 1 12 Junta 1 13 Junta 1 14 Difusor 1 15 Junta 1 16 Rodete 1 2HP 1 N Descripci n Cantidad 16 Rodete 3 4HP 1 16 Rodete 1HP 1 16 Rodete 1 5HP 1 17 Sello mec nico 1 18...

Page 8: ...SPIRE 100 y ASPIRE 150 producidas a partir del 10 01 2016 independientemente del n mero de serie son conformes con Directiva de seguridad de m quinas 2006 42 CE Directiva de compatibilidad electromagn...

Page 9: ...self priming pump for swimming pool MONOPHASIC ASPIRE...

Page 10: ...ral safety instructions General safety regulations The fitter and the user must therefore read the instructions before installation and start up These symbols indicate the possibility of danger where...

Page 11: ...t the unit from the power supply and the start up devices as the electrical parts of the pump are live during operation All assembly and maintenance work must be carried out by qualified and authorise...

Page 12: ...e RCD having a rated residual operating current not exceeding 30 mA Adjust the value of the thermal relay appropriately depending on the pump current Check the correct layout and connection of the ear...

Page 13: ...the valves and connect the motor Clean the pre filter basket regularly to avoid drops in pressure To prevent the basket from breaking do not hit it during the cleaning process Should the pump stop che...

Page 14: ...nverted motor turning Invert 2 power phases Wrong voltage Check the voltage on the characteristics plate and that of the mains Pre filter blocked Clean the filter Load loss in the installation Prevent...

Page 15: ...10 Pre filter 1 11 Cover Key 1 12 O Ring 1 13 O Ring 1 14 Difussor 1 15 O Ring 1 16 Impeller 1 2HP 1 N Description QTY 16 Impeller 3 4HP 1 16 Impeller 1HP 1 16 Impeller 1 5HP 1 17 Mechanical Seal 1 18...

Page 16: ...ty that all the pumps ASPIRE 50 ASPIRE 75 ASPIRE 100 y ASPIRE 150 Manufactured since 10 01 2016 independent of the serial number are in compliance with 2006 42 EC Machine Directive Safety prescription...