background image

       

 

 

Swimming Pool Heat Pump

 

 

 

 

INSTALLATION AND USER MANUAL

 

 

 

 

 

 

 

 

 

Model:                

PH20V ~ PHC75Vs 

 

 

 

 

 

 

Summary of Contents for PH20V

Page 1: ...Swimming Pool Heat Pump INSTALLATION AND USER MANUAL Model PH20V PHC75Vs ...

Page 2: ...hank you for choosing our product and trusting our company This manual is to provide you with necessary information for optimal use and maintenance please read it carefully and keep it for subsequent use ...

Page 3: ...t 6 Determining optimum installation position 6 Water pipe connection 9 Electric connection 10 Trial after first installation 12 III Operation guide LED controller 13 Permanent display 14 Common Setting 14 Automatic on off 15 IV Maintenance 16 V Trouble shooting Common faults 17 Failure code 18 Warranty Condition 15 16 17 18 12 13 14 12 10 9 8 5 5 3 1 1 ...

Page 4: ...ttempt to repair the system yourself Keep the main power supply switch far from children Rotating parts Never remove the grid from the fan Never place your hand or any other object in the air inlet or outlet of the heat pump Important features of this product This swimming pool heat pump is equipped with safeguards that will stop operation to protect your unit automatically and display error code ...

Page 5: ...ures The display will show EE2 if this switch is tripped Low Ambient Temperature If the air outside the heat pump is not warm enough to produce heat the system will shut down The actual point at which your unit will shut down due to low temperature varies depending on current weather conditions the amount of sunlight reaching the heat pump The shutdown can occur anywhere within a wide range of tem...

Page 6: ...evel dB A 48 48 50 56 56 58 Net Grossweight Kg 55 60 70 75 85 93 107 117 107 117 127 137 Waterpipein outspec mm 48 48 48 48 48 48 Advisedwaterflux m h 4 6 5 7 6 5 8 5 8 10 8 10 10 12 Parameters of product range C O P Coefficient of performance Note 1 Mode PH only have heat function and PHC is heat and cool optional S refers to 3 phase 2 This product can work well under air temp 0 43 Performance ca...

Page 7: ...to modification without notice A B C D E F G H PH20V 544 274 530 567 550 200 83 640 PHC30V 663 458 652 689 694 200 83 640 PHC45V 663 458 652 689 694 280 83 740 PHC60V s 663 458 652 689 694 350 83 740 PHC75Vs 724 340 706 740 694 400 83 950 ...

Page 8: ...ase refer to the following wrong operation picture Warning Because the machine is very heavy the water nozzle can not bear to be lifted during transit or installation The manufacturer cannot accept responsibility for damage incurred or repairs necessitated due to improper handling of our equipment Determining Optimum installation position The location of the swimming pool heat pump is very importa...

Page 9: ...maintenance Please refer to the following illustration A minimum of 300mm of clearance from walls shrubbery equipment etc is required around the entire pump circumference This allows for ample air intake No less than 800mm clearance on the air outlet is required to prevent re circulation of air We recommend not placing the unit underneath eaves decks or porches as this causes recirculation of disc...

Page 10: ...ibles and corrosive material to avoid any damage to this unit Never place heat pump near sprinkler systems evaporation of acid or alkaline gas If you live in an oceanfront area the heat pump should be placed out of direct spray of sand and salt since this will also clog damage and corrode the unit You may consider protecting your heat pump by planting shrubbery or a privacy fence between the unit ...

Page 11: ...ed water pump Prepared by the user The recommended pump specification flux is shown on the product specification and Max lift 10m Pipe length between heat pump and swimming pool should not be longer than 10m Noted The drawing is just for demonstration and layout of the pipes for reference 8 ...

Page 12: ...wer supply and the voltage should comply with the rated voltage of each model stated on the specification Make sure the machine is ground well Always put leakage protector according to the local code for wiring leakage operating current 30mA Protect the circuit with a suitable circuit breaker or fuse Attention The swimming pool heater must be earthed well 9 ...

Page 13: ... before connecting power supply Check the installation of the whole machine and the pipe connections according to the pipe connecting drawing Check the electric wiring according to the electric wiring diagram and ground well Make sure no blockage on the air inlet and outlet or the efficiency of the heater will be reduced or cause machine to stop operation Trial after connecting power supply Connec...

Page 14: ...cial cases In the event of an unexpected power cut the heat pump will automatically restart Check the setting and adjust if necessary In the event of an expected power cut switch off the heat pump When power is restored switch on the pump check the settings and adjust if necessary Always switch off the machine in stormy weather In any abnormal situation such as serious noise smell or smoking pleas...

Page 15: ...odehasbeenset onlyavailableontheheatandcoolmachine HEAT Shows the heat mode has been set MODE Key Heat or cool mode selection only available in heat and cool machine Down ALLOW Set required temperature and time UP ALLOW Set required temperature and time LED screen Display time temperature and machine failure code Permanent Display A The LED screen will display Time when the machine is turned off B...

Page 16: ... LED screen will return to the permanent display D When you want to check the temperature press UP ALLOW key or DOWN ALLOW key to see the current setting 3 Time setting It can be adjusted both when the machine is on or off A Press key to set time according to your local time B Time on the LED screen flashes C Press again then press UP ALLOW key or DOWN ALLOW key to set hour D Before it stops flash...

Page 17: ...normal mode 2 Time off A Press to set timer off B When the indicator light is on and the time is flashing press again to set hour Use and to adjust C Before the flashing stop press to set minute Use and to adjust D After adjusting press and water temperature will be seen 30 seconds later the controller display will be back to the normal mode 3 Cancelling the automatic mode A Press or to cancel tim...

Page 18: ...ge 2 Drain water clear of the machine Important Unscrew the water nozzle of inlet pipe to let the water flow out When the water in machine freezes in winter season the titanium heat exchanger may be damaged 3 cover the machine body when not in use B Please clean this machine with household detergents or clean water NEVER use gasoline thinners or any similar fuel C Check bolts cables and connection...

Page 19: ...ing and contract on cooling of the heat exchanger when temperature varies Not failure Automatic start or stop Check whether there is mal function on the timer Heat pump does not run A Power supply failure B Check manual power supply switch to make sure it is on C Fuse burned D If machine auto protector has started check failure code display on controller E Check whether machine automatic on or off...

Page 20: ...on due to loose wire terminal of PROT2 on the PC board B 3 phase sequence protection Contact your dealer 5 PP 1 Swimming pool heat pump sensor failure Contact your dealer 6 PP 2 Exhaust sensor failure Contact your dealer 7 PP 3 Coil pipe sensor failure Contact your dealer 8 PP 4 Intake pipe sensor failure Contact your dealer 9 PP 5 Air temp sensor failure Contact your dealer 10 PP 6 Compressor exh...

Page 21: ...n authorized dealer 1 All components in the Heat Pump carry a three year 3 Year full from the date of purchase by the original owner This warranty does not cover on site visits 2 The Titanium Heat Exchanger carries a Warranty of 10 Years made up of 3 Year 36 months full warranty followed by an additional 7 Year 84 Months pro rata replacement warranty The terms of this Warranty covers the replaceme...

Page 22: ...c Electrical connection complies with the relevant standards The Heat Pump is designed to be used with swimming pool water chemically balanced in accordance with the Langelier Index with a pH of 7 0 to 7 6 that is regularly treated with a suitable sanitizing system for a swimming pool added in compound form or generated in situ in concentrations as recommended by the relative State Health Departme...

Page 23: ...alia 115 Belmont Avenve Belmont Western Australia 6104 Phone 08 9362 4022 Fax 08 9361 3913 New South Wales 35 15 Valediction Road Kings Park NSW 2148 Phone 02 9671 7041 Fax 02 9671 7963 Victoria Phone 1300 656 956 Fax 1300 502 508 Queensland 2 246 Evans Road Salisbury QLD 4107 Phone 07 3277 4958 Fax 07 3272 9091 ...

Page 24: ...21 Version H23 100707 ...