background image

Issue Date: 22/1/2020 
 

 

 

 

 
 
 

 

 

 

WIRELESS MINI WALL MODULE 

MWMR-2300 

 

 
 

CONTENTS 

 

1.  Overview and features   

 

 

 

 

 

 

 

Page 2. 

2.  Diagrams   

 

 

 

 

 

 

 

 

 

 

Page 3. 

3.  Installation 

– Wiring  

 

 

 

 

 

 

 

 

Page 4. 

4.  Pairing / Un-pairing device 

 

 

 

 

 

 

 

Page 7. 

5.  Delay Off timer setup 

 

 

 

 

 

 

 

 

Page 9. 

6.  Operation   

 

 

 

 

 

 

 

 

 

 

Page 11. 

7.  Specifications   

 

 

 

 

 

 

 

 

 

Page 12. 

 

 

Summary of Contents for MWMR-2300

Page 1: ...LESS MINI WALL MODULE MWMR 2300 CONTENTS 1 Overview and features Page 2 2 Diagrams Page 3 3 Installation Wiring Page 4 4 Pairing Un pairing device Page 7 5 Delay Off timer setup Page 9 6 Operation Page 11 7 Specifications Page 12 ...

Page 2: ...l Module Compatible to L and M series Small compact size for installation into wall box or inside light fittings Delay off timer 1M 10M 1H 4H select by trimmer resistor 32 memories first in first out storage maintain Scene status memory create your desired atmosphere 2 way switch function Not compatible to ARC Code switch system product range OVERVIEW AND FEATURES ...

Page 3: ...r load wire S Terminal for power supply to the switch L Terminal for live wire Strip the solid wires rigid conductor only at least 7mm then connect the wires as per diagrams below ensure terminals are properly tightened and no bare wire is visible Suitable wire size for terminal is 1 6mm2 to 2mm2 DIAGRAMS ...

Page 4: ...4 Issue Date 22 1 2020 3 Installation Wiring Cut off main power before installing and wiring Current existing house wiring should be as below INSTALLATION WIRING ...

Page 5: ...o module terminal L 2 Connect Neutral wire into module terminal N 3 Connect wire from module terminal L N to Load 4 Connect switch Live wire from module terminal S into switch L1 terminal 5 Connect permanent Live wire into switch Com terminal 6 Connect back mains power supply INSTALLATION WIRING ...

Page 6: ...manent Live wire into module terminal L 3 Connect Neutral wire into module terminal N 4 Connect wire from module terminal L N to Load 5 Connect permanent Live wire into switch 1 Com terminal 6 Connect switch Live wire from module terminal S into switch 2 Com terminal 7 Connect wire from module terminal L N to Load 8 Connect back mains power supply INSTALLATION WIRING ...

Page 7: ...mode 2 With a remote control press the ON button LED on module will flash to confirm that the remote control is now paired NOTE If no signal is received from a remote control within 12 seconds then the module will automatically exit learning mode without pairing the device To exit learning mode manually simply press the Learn button again PAIRING UN PARING DEVICE ...

Page 8: ...ss the OFF button intended to be un paired LED on module will flash to confirm that the remote control is un paired CLEARING ALL MEMORY Removing all memory stored in the module 1 On the module hold down the Learn button for 6 seconds LED on module will flash 2 Release button then press again this will remove all memory stored in the module PAIRING UN PARING DEVICE ...

Page 9: ...ctions 1 min 10 mins 1 hour 4 hours Adjust rotary switch clockwise to the hours that you wish to setup LED on module will blink once to confirm the mini wall module is properly setup in each time slot Timer will only remember the first activate timer If during timer count down you adjust the time slot mini wall module will ignore the new timer until the current timer ends or you manually turn OFF ...

Page 10: ...ule will blink once to confirm 2 Turn ON mini module and timer will start to count down 3 Once timer reaches to 1 minute it will automatically turn OFF 4 If during the count down the mini module is turned OFF then this will automatically deactivate the timer count down DELAY OFF TIMER SETUP ...

Page 11: ...ker switch If load is switched ON from the rocker switch then switch OFF via the remote control The next time turning ON the load can either be i on the remote press the ON button OR ii on rocker switch toggle switch once Rocker Switch Two way operation Turn the load ON Toggle switch once to turn ON load Turn the load OFF Toggle switch once again to turn OFF load Operation example Switch 1 is loca...

Page 12: ...e CE marked affixed to this product confirms Its complaisance with the European Directives Which apply to the product and in particular its compliance with the harmonizes standards and specifications Dimension L x W x H 45 x 40 x 15 2mm Weight 20 g NOTE Please leave minimum of 1 5 meters in between 2 or more modules When inserting module into back box make sure excess wires do not cover module s b...