background image

USER MANUAL

REV.01-07/20

English version

ArcPod 

15Q

Compact 15x10W RGBW/Fc 

outdoor IP66 LED wash light 

for exterior installations

Summary of Contents for ArcPod 15Q

Page 1: ...USER MANUAL REV 01 07 20 English version ArcPod 15Q Compact 15x10W RGBW Fc outdoor IP66 LED wash light for exterior installations ...

Page 2: ...ct loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www musiclights it or can be inquired to the official ARCHWORK distributors of your territory https www musiclights it sales_network html Scanning the below QR Code you will access the dow...

Page 3: ...NSTRUCTIONS FOR A RELIABLE DMX CONNECTION 8 CONNECTION DAISY CHAIN OF THE DMX LINE 8 CONNECTION DAISY CHAIN OF THE DMX LINE 8 DMX ADDRESSING 9 DMX ADDRESSING 9 7 RDM FUNCTIONS 9 7 RDM FUNCTIONS 9 8 OPERATION VIA DATAMASTER 10 8 OPERATION VIA DATAMASTER 10 RDM SETTING 10 RDM SETTING 10 STAND ALONE FUNCTION 11 STAND ALONE FUNCTION 11 9 DMX CHARTS 12 9 DMX CHARTS 12 10 ACCESSORIES INSTALLATION 14 10 ...

Page 4: ...perature Ta Do not operate the fixture if the ambient temperature Ta exceeds 45 C 122 F Protection from burns and fire The exterior of the fixture becomes hot during use Avoid contact by persons and ma terials Ensure that there is free and unobstructed airflow around the fixture Keep flammable materials well away from the fixture Do not attempt to bypass thermostatic switches or fuses Permanent Ou...

Page 5: ... partners are permitted to open the fixture Users may carry out external cleaning following the warnings and instructions provided but any service operation not described in this manual must be referred to a qualified service technician Important Excessive dust smoke fluid and particle build up degrades performance causes overheating and will damage the fixture Damages caused by inadequate clean i...

Page 6: ... flaps to adjust the light beam ARCPOD15Q DATAMASTER RDM DMX tool cable tester 5p XLR connectors pouch charging cable XLR adapt ers AWEXAC1L03 IP67 power extension cable for ARCHWORK projectors L 03 m AWEXAC1L05 IP67 power extension cable for ARCHWORK projectors L 05 m AWEXAC1L10 IP67 power extension cable for ARCHWORK projectors L 10 m AWEXAC1L20 IP67 power extension cable for ARCHWORK projectors...

Page 7: ...afety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame For fixed installation use M8 bolts Do not use removable parts or weak anchors for secondary attachment Warning When clamping the fixture to a truss or other structure at any angle use clamps of half cou pler type Do not use any type of clamp that does not completely encirc...

Page 8: ...1 POWER IN for connection to a mains 100 240V 50 60Hz The max power consumption is 120W 2 DMX IN 3 pole 1 GND 2 sign 3 sign 3 DMX OUT 3 pole 1 GND 2 sign 3 sign 4 POWER OUT power output for connection of multiple units in series Fig 3 1 2 3 4 ...

Page 9: ...cian You can link up tp 7 units at 120 V 14 at 230 V Never exceed this number Power linking cords can be purchased separately When connecting the unit to a local power it may be necessary to use the Schuko to IP67 adapters supplied with this product Core EU Core US Connection Plug terminal marking Brown Black Live L Blue White Neutral N Yellow green Green Earth E Fig 4 MALE POWER IP67 CONNECTOR FE...

Page 10: ... to your DMX network it is necessary to use the adapters XLR 5 pin IP67 signal connector supplied with this product CONNECTION DAISY CHAIN OF THE DMX LINE Connect the DMX data output from the DMX source to the product DMX input male connector Run the data link from the product DMX output female connector connector to the DMX input of the next fixture Terminate the data link by connecting a 120 Ohm...

Page 11: ...h out enough control channels for the product Set the fixture s DMX address by RDM with the DATAMASTER Parameter PID GET SET DMX_PERSONALITY 0x00e0 X X DMX_PERSONALITY_DESCRIPTION 0x00e1 X X CURVE 0x0343 X X MODULATION_FREQUENCY 0x0347 X X IDENTIFY_DEVICE 0x1000 X FACTORY_DEFAULTS 0x0090 X X WBANLANCE_R 0x8200 X X WBANLANCE_G 0x8201 X X WBANLANCE_B 0x8202 X X WBANLANCE_W 0x8203 X X FULL ON_Mode Fu...

Page 12: ... m 197 ft Otherwise you might need to use an RDM optically isolated signal amplifier RDM SETTING To set the RDM functions with the DATAMASTER follow these steps Turn on the DATAMASTER Select the RDM function Wait the discovering of all units Select the desired unit and press ENTER button Change the value of the desired function The following chart describes the RDM menu tree of the product the ter...

Page 13: ...ual Color or Effect function Select Head 1 Select the desired color or effect with speed The projector where is setted the STAND ALONE values is a MASTER projector If there isn t the DMX controller or the DMX missing this projector will send his STAND ALONE value on the DMX line On others units that will be connected to the same DMX line must NOT be setted the STAND ALONE they will be SLAVE and th...

Page 14: ... DIMMER DIMMER 2 GREEN RED RED 3 BLUE GREEN GREEN 4 WHITE BLUE BLUE 5 DIMMER SPEED MODE WHITE WHITE 6 STROBE STROBE 7 DIMMER SPEED MODE COLOR MACRO 8 EFFECTS 9 EFFECTS SPEED 10 DIMMER SPEED MODE ARCHWORK ArcPod 15Q 12 9 DMX CHARTS ...

Page 15: ...150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 000 5 7 DIMMER SPEED MODE Preset dimmer speed from display menu Dimmer speed mode off Dimmer speed mode1 fast speed Dimmer speed mode2 middle speed Dimmer speed mode3 slow speed 000 051 052 101 102 152 153 203 204 255 000 8 EFFECTS No Function Effect 1 Effect 2 Effect 3 Effect4 Effect5 Effec...

Page 16: ...ARCHWORK ArcPod 15Q 14 1 2 3 4 5 1 Remove the front cover 1 by loosing the screws Then remove the front glass 2 rubber seal 3 lens holder 4 and the lens 5 2 Replace the lenses by inserting the two pins on the back of the lens with the holes provided on the PCB LED NOTE to reassemble the lenses the reverse procedure NOTE it is recommended to tighten the front cover screws carefully so as to guarant...

Page 17: ...djust the light beam is available as optional accessory 15 ARCHWORK ArcPod 15Q Insert the three to positioning and the spring pin on the hardware into the holes provided on the top and down side edge of the product NOTE To remove the accessory reverse the procedure Fig 10 ...

Page 18: ...actors such as the amount of the use and the condition of the installation environment It is recommended that the product is subject to annual service by a qualified technician for special maintenance involving at least the following procedures General cleaning of internal parts All other service operations on the product must be carried out by MUSIC LIGHTS its approved service agents or trained a...

Page 19: ...ectly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after fixture reset One or more hardware components requires mechanical adjustments Check product stored error messages for more information Contact MUSIC LIGHTS Service or an authorized service partner Mechanical effect loses pos...

Page 20: ...MUSIC LIGHTS S r l Phone 39 0771 72190 www musiclights it ...

Reviews: