background image

PAR LED RGBWA

User's Manual

Spot LED RGBWA IP65 with DMX control

AR3333­RGBWA

Summary of Contents for AR3333--RGBWA

Page 1: ...PAR LED RGBWA User s Manual Spot LED RGBWA IP65 with DMX control AR3333 RGBWA ...

Page 2: ...aler for any operation Always ensure that the structure to which you are attaching the unit is secure and is able to support the weight of each unit Always make sure you are using a safety chain connected to the unit When assembling make sure that the cable glands are tightened for a watertight seal Avoid installing the unit close to heat sources Never lean the power cord on hot unit surfaces Allo...

Page 3: ...ed your Arena Luci dealer for assistance INSTALLING THE PROJECTOR Attach the projector by means of the central hole diameter 11mm on the forks for suspended applications you must also fix the projector with a safety chain securing it to the support structure and the ring arranged on the projector There are two other 11mm diameter holes on the fork to use with special fasteners Loosen the side knob...

Page 4: ... female connection joints not included in the case of outdoor installation the pairs of joints must have the most suitable degree of protection for the environment Connect the power cord lines to the joint terminals respect the indicated L N E polarity color brown L blue N yellow green E It is essential that each projector is correctly earthed and that electrical installation conforms to all the s...

Page 5: ...portant that the signal wires do not make contact with each other and do not touch the casing of the plug The casing of the plug must not be in contact with other objects possible sources of disturbance The projector has a DMX INPUT input cable and a DMX OUTPUT output cable The coloring of the signal wires used in the projector is as follows DATA Blue DATA Brown The three terminals have the number...

Page 6: ...mation being sent out from the controller This digital encoding must be done on each projector The start address of the coding is assigned by setting the desired value using the display interface on the rear panel Press the MENU button on the keypad the display shows the word Addr Press ENTER the current set address appears on the display Use the UP and DOWN keys to select the desired starting add...

Page 7: ...color U White color g Green color A Amber color b Blue color P not used Press ENTER in correspondence with the desired color the display shows the current intensity value stored for the chosen color in DMX units 0 to 255 Press the UP or DOWN buttons as many times as required to reach the desired intensity level For fast forward press and hold the button Press ENTER to store the value or press MENU...

Page 8: ...figuration submenu in which you can move with the UP or DOWN keys SIgN the option is not active on this device However for correct operation it must be set to 1 Press ENTER move inside the new submenu with the UP or DOWN keys 1 press ENTER to confirm 2 not active NOS this option allows you to determine the behavior of the projector when the DMX signal is disconnected Press ENTER move inside the ne...

Page 9: ...ll channels of the projector Channel Dimmer The intensity of the light is linearly variable from off to maximum in particular for the DMX value equal to 0 the LED source is turned off for intermediate increasing values the brightness gradually increases for the value 255 the LED source is turned on at maximum intensity Channel Strobe The projector is able to generate an electronic strobe effect ob...

Page 10: ...alues the brightness gradually increases for the value 255 the blue source is turned on at maximum intensity Channel White The intensity of the white source is linearly variable from off to maximum in particular for the DMX value equal to 0 the source is turned off for intermediate increasing values the brightness gradually increases for the value 255 the white source is turned on at maximum inten...

Page 11: ...11 12 USER S MANUAL ...

Page 12: ...l not be treated as household waste but must be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is correctly disposed you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling The recycling of materials will help to conser...