background image

 

 

IPN-8U Network switching 

module 

ARMT.665200.006UM 

User Manual 

 
 

Document version 14                                                                                                26.30.11.120 

2021 

 

ENG 

Summary of Contents for IPN-8U

Page 1: ...IPN 8U Network switching module ARMT 665200 006UM User Manual Document version 14 26 30 11 120 2021 ENG ...

Page 2: ...armtel com Armtel info armtel com ...

Page 3: ...ntercom and Public address General alarm communication systems IPN 1 1 Short name of the product IPN 8U Maintenance personnel for the IPN 8U shall be appointed by the management at the installation site The maintenance personnel shall be required to know the operating procedure of the IPN 8U to the extent provided for by the User Manual Duties of the maintenance personnel shall include maintenance...

Page 4: ...ecting the product to the power supply make sure the power and communication cables are properly insulated protect the power and interface cables from damage To avoid electric shock do not turning on the device with damaged power and interface cables Do not use the product in rooms with high humidity more than 80 or conductive dust ATTENTION DISASSEMBLY OF ARTICLE CONNECTED TO POWER SUPPLY IS PRO ...

Page 5: ...tions 17 2 4 Installation connection and disassembly 18 2 5 Operation 19 2 5 1 Procedure of actions of the service personnel when using the product 19 2 5 2 Configuration 19 2 5 3 Functions of the product 19 2 5 4 Monitoring of the product operation 19 2 5 5 Troubleshooting 21 3 MAINTENANCE 22 3 1 General 22 3 2 Safety precautions 22 3 3 Product maintenance procedure 22 3 4 Checking the functional...

Page 6: ...igital subscriber units and ACM modules with Uk0 interface produced by LLC Armtel digital subscriber IP units with Ethernet interface and ACM IP modules pro duced by LLC Armtel SIP telephone sets and other equipment of the third party manufacturers fed by PoE according to standard IEEE 802 3af 2003 Class 0 digital recording units IP with Ethernet interface data transmission equipment with interfac...

Page 7: ... the following functions connection of up to eight 8 digital subscriber units with Uk0 interface to a distance of up to 6 km via a copper cable line power supply of subscriber units via Uk0 interface connection of up to four IP devices or network equipment with interface Ethernet 100BaseT and switching of IP connections between them power supply of subscriber IP devices by PoE function storing of ...

Page 8: ...e indication for subscriber status of U interfaces and Ethernet ports servicea bility of fuses and power circuits operating modes of the central processor of IPN 8U module using two color LED indicators on the front panel Detailed description of the functional area for IPN 8U and its programming method are given in operational documents for IPN 1 1 system which includes IPN 8U 1 2 Specifications I...

Page 9: ...l characteristics Parameter Value Rated voltage V 48 Supply voltage range V from 36 to 60 Maximum power consumption of IPN 8U without PoU PoE max W 9 1 Maximum load current of each Uk0 port max mA 300 Maximum distance to a subscriber unit km 6 0 Number of ISDN Uk0 interfaces 8 ports with PoU Size of integrated switch Fast Ethernet 100 Mb s 4 ports with PoE Feeding unit class by standard PoE IEEE 8...

Page 10: ...ed with Power over U function phantom power supply of subscribers with automatic overload protection which allows connecting digital subscriber devices by one pair of wires for a distance of up to several kilometers depending on the cable cross sec tion The power supply function on each Uk0 interface is executed by a program accord ing to the configuration data of IPN 8U Connection of subscriber l...

Page 11: ... PoE 1 4 fuse and indicator of the fuse state in power supply PoU ports MAIN indicators to monitor the secondary DC power supply source 3 3 V and 5 V CPU indicator of CPU state blinking green color refers to normal operation mode RES reset key 8 PoU 1 8 indicator of digital Uk0 interfaces and subscriber units connect ed to them two color LEDs 4 PoE Ports 1 4 sockets type RJ 45 ports 100BaseT Fast ...

Page 12: ... be returned to the default settings from the memory file default par After re leasing S2 automatic loading of new parameters will occur X2 JTAG connector for initial programming at the manufacturer X5 COM port for connection of diagnostics PC X4 functional jumper for coming into loading mode If contacts of X4 are closed during power ON or restart then the loading program will start The mode of lo...

Page 13: ...ed memory Embedded software configuration data files and HTML pages of WEB interface are stored in non volatile flash memory Two sets of Infineon chips are connected to the processor via IOM 2 lines four Uk0 interfaces each Ethernet interface of the processor is connected to embedded Ethernet switch chip four of which are connected to the front panel of IPN 8U Each of these net work interfaces is ...

Page 14: ...ication system and is designed for use in premises with harsh operation conditions outdoors under influence of precipitations dust within low temperature condi tions and high noise levels DW unit consists of a speaker microphone and re lay for switching of external signaling devices such as siren or light signal de vice incorporated into IPN communication system can be applied DW units equipped wi...

Page 15: ...ress systems with radio network devices via radio connection module control of the switching of signaling devices and external alarm systems automatic playback of pre recorded messages by commands from external alarm systems etc Functional area and configuration parameters of subscriber units as well as key func tions are determined in the configuration data for IPN 8U module and correspond to the...

Page 16: ...of the manufacturer product name and description temperature range degree of protection provided by enclosures IP code rated supply voltage value commercialization mark for products on the market of Customs Union member states electrical class III mark according GOST IEC 61140 2012 special waste disposal mark product serial number date of manufacture The serial number and MAC address are indicated...

Page 17: ...information of the manufacturer handling symbols according to GOST 14192 96 and CU TR 005 2011 commercialization mark for products on the market of Customs Union member states serial number and date of manufacture The package is made according to the drawings of the product manufacturer and en ables storage of the IPN 8U provided requirements set in Section 5 are met For shipment of the IPN 8U fro...

Page 18: ...not be predicted estimated or verified and which the manufacturer was unable to factor in during development may exist or arise during operation at the op erating facility In the event of such factors find another operating site where said factors do not ex ist or do not affect operation of the product 2 2 Preparation for operation Preparation of IPN 8U for operation should be performed by Manufac...

Page 19: ...o it 5 Disconnect the service computer connect earlier disconnected IP devices and the network equipment 6 Write the installed IP address in the product passport 2 3 Safety precautions During installation and operation observe safety precautions laid out in Occupation al safety rules when operating electrical installations when working with electrical receiv ers with voltage of up to 1000 V To avo...

Page 20: ...e ter minal block terminals is shown in Table B 1 4 Connect the power cable to POWER socket of IPN 8U see Figure 2 and then to the power supply Pin 3 of the power cable connector must be connected to the common ground bus of the cabinet rack If necessary connect the functional grounding to the terminal located on the rear wall of the housing 5 After the power is turned ON the firmware is downloade...

Page 21: ... 5 2 Configuration After the power is successfully turned on and the device is loaded you can configure the connections of IPN 8U To do this you can use the administration software of IPN1 1 system please refer to Decentralized loudspeaker system IPN1 1 User Manual Part 2 Administrator Manual RMLT 465300 001UM1 To identify the device you need to use the record of IP address installed during the pr...

Page 22: ... mode Orange indicator of Ethernet PoE ports 1 4 OFF Источник напряжения PoE voltage source is faulty or not activated Solid ON PoE source found a compatible device load and turned on the feed power to this port Shortly blinking PoE source is looking for a compatible de vice load on the port Green indicator of Ethernet PoE ports 1 4 OFF No connection to the network Solid ON Network connection is i...

Page 23: ... de vices connected to Ethernet ports 1 4 Find the cause fix it and replace the fuse Indicator of one of the ports 1 8 is OFF Port is not configured Port is not in volved in configuration Make configuration Indicator of some of the Uk0 ports 1 8 is RED The subscriber device cable is faulty Change the subscriber de vice cable The subscriber device is faulty or not connected to the power supply sour...

Page 24: ...operating electrical installations 3 3 Product maintenance procedure Maintenance and servicing include the following activities visual inspection of IPN 8U enclosure for mechanical damages cracks dents etc on the enclosure cover and control elements are not allowed removal of dust and dirt from the product surface checking the product mounting in the cabinet rack and fixing of outside sockets visu...

Page 25: ...d with the unit identified malfunctions as well as negative results of the maintenance should be recorded in special logs 3 4 Checking the functionality of the product The operability of the IPN 8U is checked automatically when it is turned on and the LED indication is checked in accordance with the instructions given in Tables 3 and 4 If necessary it is allowed to change the configuration of the ...

Page 26: ...el com Armtel info armtel com ENG 4 REPAIR Scheduled repairs of the product are not provided for Unscheduled repair shall be performed by the manufacturer at the request of the user The location time procedure and cost of the work shall be agreed on in advance ...

Page 27: ...E Product storage conditions IPN 8U in the manufacturer s consumer package in un heated and ventilated warehouses or storage facilities with controlled air conditioning with a temperature range up 5 to 40 С Air in the product storage premises must be free of corrosive foreign matter acid fumes alkalis ...

Page 28: ...N THE TRANSPORTATION OF THE IPN 8U EXCHANGE MOUNTED INTO THE COMMUNICATION RACK WITHOUT ADDITIONAL MOUNTING ELE MENTS FOR STRONG FIXING IS STRICTLY FORBIDDEN THIS MAY CAUSE DAMAGE TO OR DESTRUCTION OF PRODUCT At the same time it is allowed to transport the IPN 8U subscriber connection cable intended for installation on a DIN rail as part of the communication rack At this it is nec essary to take m...

Page 29: ...info armtel com Armtel ENG 7 DISPOSAL The product shall not be disposed of together with household waste and must be de livered to a special center for the disposal of electronic products The operating organiza tion shall be responsible for the disposal of the product ...

Page 30: ...devices IEEE 802 3af standards provide for two schemes of remote power supply for Ethernet networks see Figure A 1 A Using high frequency transformers at both ends of the line with the central tap from the windings DC voltage is supplied to the central taps of the secondary windings of these transformers and it is taken from the central taps on the receiving side B Using of free pairs to connect p...

Page 31: ...owered device V from 36 to 57 nominal 48 V Voltage range of the source V from 44 to 57 Maximum power of the PoE source W 15 4 Maximum power received by PoE consumer W 12 95 Maximum current mA 350 Maximum cable resistance Ohm 20 for cat 3 Thus PoE power supply source used to power IPN 8U must comply with the requirements of 802 3af 2003 standard with limited load not worse than Class 0 see Table A ...

Page 32: ...ith screw terminals for connection of U interface lines The appearance of IPN 8U subscriber connection cable is illustrated at Figure B 1 Figure 5 Appearance of the IPN 8U subscriber connection cable Figure 5 Appearance of IPN 8U subscriber connection cable Figure B 1 Appearance of IPN 8U subscriber connection cable Designation of the terminal block outputs is given in Table B 1 Table 2 Designatio...

Page 33: ...nnection cable IPN 8U according to Table B 1 Б 2 Power cable The cable is connected to the POWER connector plug see Figure 2 of the product and then to the power source The appearance of IPN 8U POWER socket with the numbering of contacts is illustrat ed at Figure B 2 1 48 V from the power source 2 0 V from the power source 3 GND for grounding of IPN 8U enclosure should be connected to the common g...

Page 34: ...IPN 8U NETWORK SWITCHING MODULE USER MANUAL page 32 32 armtel com Armtel info armtel com ENG NOTES ...

Page 35: ...armtel com info armtel com Armtel ...

Page 36: ...gal and physical address 12 buildung 1 Zaporozhskaya street office 1 2 Saint Petersburg 192012 TECHNICAL SUPPORT 8 800 500 90 17 for calls from Russian Federation 7 812 633 04 02 for international calls support armtel com MORE INFORMATION ABOUT PRODUCT ON OFFICIAL SITE ...

Reviews: