OPERATOR’S MANUAL
650556
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
AIRLESS SPRAY PUMP SYSTEM - CART MOUNTED
SISTEMA DE BOMBA PULVERIZADORA SIN AIRE - MONTADO EN CARRETILLA
SYSTÈME DE POMPE DE PULVÉRISATION SANS AIR - MONTÉ SUR CHARIOT
650556
INCLUDE MANUALS: 66301-X LOWER PUMP END (PN 97999-647), 650684-X PUMP (97999-656), 65142X-X
FILTER (97999-6), GENERAL INFORMATION S-636 (97999-636)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
6” STAINLESS STEEL, TWO BALL PUMP, 45:1 RATIO
RELEASED / LIBERADO / DECHARGE: 5-1-96
REVISED / REVISADO / REVISE:
1-18-11
(REV. E)
SERVICE KITS
x
Use only genuine ARO
R
replacement parts to assure compatible
pressure rating and longest service life.
x
61355 for repair of Air Motor section.
Service Note: The Air Motor Service / Parts Manual is not shipped
with the pump but it is included with each Service Kit. If this Service /
Parts Information is needed, request the Air Motor Operator’s Manu-
al from ARO. (Manual 6564X-X, PN 97999-174).
x
637306-P43 for repair of Lower Pump section.
PUMP SYSTEM DATA
Model
650556
. . . . . . . . . . . . . . . . . . .
Pump System Type
Cart Mounted Portable,
. . . . . . . . .
Air Operated, Two Ball S’Steel
Pump Model
650684-P43
. . . . . . . . . . . . . .
Ratio
45:1
. . . . . . . . . . . . . . . . . . . .
Air Inlet
1/2”-14 N.P.T.F.-1 (female)
. . . . . . . . . . . . . . . . .
Air Exhaust
Muffler included
. . . . . . . . . . . . . .
Material Inlet
Suction Tube
. . . . . . . . . . . . .
Dimensional Data
See page 3.
. . . . . . . .
Air Motor
65665-B
. . . . . . . . . . . . . . . . .
Motor Repair Kit
61355
. . . . . . . . . .
Lower Pump End
66301-P43
. . . . . . . . . . .
Lower Pump Repair Kit
637306-P43
. . . . .
Weight (less carton)
111 Lbs (50 Kgs)
. . . . . . .
PERFORMANCE
Air Inlet Pressure Range
30-120 p.s.i. (2-8.3 bar)
. . . . .
Fluid Pressure Range
1350-5400 p.s.i. (93-372 bar)
. . . . . . .
Max. Rec’d Cycles / Minute
60
. . .
Displacement In
3
Per Cycle
7.5
. . .
Volume / Cycle
4.1 oz. (121 ml)
. . . . . . . . . . . . .
Cycles Per Gallon
30.9
. . . . . . . . . .
Flow @ 60 Cycles / Minute
1.9 g.p.m. (7.2 lpm)
. . . .
Noise Level @ 60 Psi - 40 Cpm
84.8 db(A)
*
The pump sound pressure level has been updated to an Equivalent Continuous Sound Level
(L
Aeq
) to meet the intent of ANSI S1. 13-1971, CAGI-PNEUROP S5.1 using four microphone
locations.
OPERATING INSTRUCTIONS
WARNING
DO NOT EXCEED MAXIMUM OPERATING PRESSURE
OF 5400 P.S.I. (372 BAR) AT 120 P.S.I. (8.3 BAR) AIR INLET PRESSURE.
WARNING
REFER TO THE PUMP MANUAL FOR ADDITIONAL OP-
ERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT IN-
FORMATION.
FIGURE 1
IMPORTANT This is one of the five documents which support the
system. Replacement copies of these forms are available upon
request.
-
66301-X LOWER PUMP END OPERATOR’S MANUAL
(97999-647)
=
650556 PUMP SYSTEM MANUAL (97999-670)
-
650684-X PUMP MODEL OPERATOR’S MANUAL (97999-656)
-
65142X-X MATERIAL FILTER (97999-6)
-
GENERAL INFORMATION MANUAL S-636 (97999-636)
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 495-0276
FAX(800) 892-6276
©
201
1
CCN
99610990
www.ingersollrandproducts.com