Page 3: ...ensteckverbinder 13 8 Anschlußbelegung Fernsteuerung 13 9 Ansicht Gerätefront 14 10 Ansicht Geräterückseite 14 English Contents Page 1 General Remarks 8 2 Important Safety Instructions 8 3 Product Description 9 4 Start Up Procedure 10 4 1 Energizing System 10 4 2 Control of Light Intensity 10 4 3 Boost Operation 10 5 Technical Data 11 6 Trouble Shooting Guide 12 7 Connector Wiring Mains and Lamp C...

Page 4: ... Gerät auszuschalten Es dürfen nur original Lampenkabel mit für die Lampenleistung zugelassenem Querschnitt zum Anschluß der Leuchte an das Vorschaltgerät verwendet werden Das Gerät darf nur mit Scheinwerfern betrieben werden die mit einer UV Schutzscheibe ausgerüstet sind Es sind geeignete Maßnahmen vorzusehen die es verhindern daß das EVG bei fehlendem oder defektem UV Schutz in Betrieb genommen...

Page 5: ...t Es ist nur für professionelle Anwendungen vorgesehen Das Elektronische Vorschaltgerät EB 4000 Booster ist speziell für den Betrieb von 4000 W Metalldampf Entladungslampen abgestimmt Die Betriebsart ist so gewählt daß die Lampe mit rechteckförmigem Strom und konstanter Leistung betrieben wird Auf diese Weise wird eine optimierte flackerfreie Lichtemission der Lampe erzielt In einer speziellen Boo...

Page 6: ...kW Betrieb ca 450 W Geprüfte Leuchte an das EVG anschließen Fernsteuerung mit dem EVG verbinden EVG an das Netz anschließen Netzautomaten am EVG einschalten EVG über die Fernsteuerung einschalten Das EVG startet und die LED Ballast On leuchtet Nach ca 3 Sekunden wird die Leuchte automatisch gezündet Die LED Lamp On leuchtet wenn der Zündvorgang erfolgreich war 4 2 Einstellung der Lichtintensität D...

Page 7: ...6 HSB F Lampenleistung 4200 W konstant geregelt 8400 W konstant geregelt im Boost Betrieb Stromverlauf Rechteckstrom 75 Hz Dimmung Bereich 50 bis 100 des Nennwertes Zündung Heiß und Kaltstart Lichtrippel typ 3 Abmessungen B H T 482 mm 19 177 mm 4 HE 490 mm Gewicht ca 23 kg Schutzart IP 20 Fernsteuerung Typ Analoger Fernsteueranschluß Funktionen Vorschaltgerät Ein Aus Dimmung Boost Ein Aus Rückmeld...

Page 8: ...ktionstüchtig ist ist eine geprüfte Leuchte direkt ohne Verlängerungskabel an das EVG zu schalten 6 7 Wenn das EVG nach einigen Minuten abschaltet können verschiedene Ursachen vorliegen Die Lampe selbst kann fehlerhaft sein oder das Ende ihrer Lebensdauer erreicht haben Die Thermoschalter im EVG könnten aktiviert sein weil die Umgebungstemperatur zu hoch ist oder das EVG direkter Sonnenbestrahlung...

Page 9: ... permitted cross section of the leads Use only luminaires equipped with an UV safety screen Safety measures must realize to prevent operation of luminaires with missing or defective UV safety screen 2 5 The Electronic Ballast satisfies the standards of the recognized state of the engineering and the pertinent safety regulation of DIN EN 60598 1 2 6 Supply voltage must not exceed the ranges that ar...

Page 10: ...ed in a suitable 19 Cabinet Rack or housing It is suitable for professional indoor use IP20 protection The Electronic Ballast EB 4000 Booster is part of an optimized lighting system along with 4000 W metal halide lamps The lamp will be supplied with controlled lamp power and square wave current In this way light emission will be flicker free and delivers daylight on high quality A special feature ...

Page 11: ...onnect properly checked daylight luminaire to the ballast Connect the remote control to the ballast Connect the electronic ballast to the power supply source Set main circuit breaker to On position Use remote control to switch on the ballast Ballast starts and LED Ballast on is lit Lamp will ignite after about 3 sec The yellow LED LAMP on front plate is lit after successful ignition 4 2 Control of...

Page 12: ...nt control 8400 W constant control in boost mode Current Characteristic square wave 75 Hz Dimming Range 50 100 of nominal Lamp power Starting cold start and hot restrike typical light ripple typ 3 Dimensions width height depth 482 mm 19 177 mm 4 HU 490mm Weight approx 23 kg Protective Rate IP 20 Remote Control Type Analog remote control Function Ballast on off Dimming Switching Boost on off Check ...

Page 13: ... If a ballast cuts out after running a few minutes there are a number of possible failures The lamp itself may be faulty or at the end of its life The thermal cutout in the ballast may have activated red LED Temp due to extreme ambient temperature or exposure to direct sunlight in hot summer conditions The ventilation might be restricted In such a case the ballast can be used after it had cooled d...

Page 14: ...0 250V 2 Rechteck wandler Square Wave Converter Spannungsversorgung Power Supply Lampe Hi Lamp Hi Lampe Lo Zündgerät Funktion Function S1 Sicherheitsschalter Safety Switch 5 4 3 S1 Zündgerät Igniter 2 1 EB 4000 Booster Lampe Lamp 1 L N PE PE HAN 6 HSB F HAN 6 HSB M Abb 1 Anschlußbelegung Netz und Leuchtensteckverbinder Fig 1 Connector Wiring Mains and Lamp Connector 12V Remote Control Pin 4 5 10V ...

Page 15: ...zähler Hours Counter Netzautomat Main Circuit Breaker Abb 3 Ansicht Gerätefront Fig 3 Front view of ballast 2 3 1 4 5 6 Fernsteueranschluß Remote Control Connector HAN 8U Lampensteckverbinder Lamp Connector HAN 6 HSB F Netzstecker Line Connector HAN 6 HSB M 1 3 2 5 4 6 1 3 2 5 4 6 Abb 4 Ansicht Geräterückseite Fig 4 Rear view of Ballast ...