background image

Artistic Licence

railSplit dmx User Guide

railSplit dmx

Version 1-3

User Guide

Summary of Contents for railSplit dmx

Page 1: ...Artistic Licence railSplit dmx User Guide railSplit dmx Version 1 3 User Guide ...

Page 2: ... inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product is designed for indoor use only If used outdoors it MUST be installed in an appropriate IP rated cabinet Do not allow this product to be exposed to rain or moisture Do not allow liquid to penetrate ...

Page 3: ... feature is not required then the signal must be terminated The product contains an internal termination resistor This is enabled by fitting a wire link between Term and DAT 10 mm 88 mm 90 mm 62 mm 4 mm Rail Split DMX DMX512 Splitter with galvanic input isolation Artistic Licence DATA COM DATA Output 2 DATA COM DATA Output 3 DATA COM DATA Output 4 DATA COM DATA Output 1 GND 9 48V Power DATA COM DA...

Page 4: ... The DMX512 input is attached via three screw terminals Please refer to the connections diagram Loop through A passive loop through connection allows onward connection to other DMX512 devices If this feature is not required then the signal must be terminated The product contains an internal termination resistor This is enabled by fitting a wire link between the screw terminals that will terminate ...

Page 5: ... Internal Logic Ground Internal Logic Ground Connected to power supply 0V If the selected PSU has a connection between Earth Ground and 0V the DMX outputs become Ground Referenced Otherwise the DMX outputs are Floating When the recommended PSU is used DMX outputs are Floating The following table summarises the internal earth interconnection and isolation Please note that we use the term Earth Grou...

Page 6: ...ived DMX512 Each output can drive an additional 32 devices LED Indication The indicators have the following meaning Top Data OFF No data received Green DMX activity zero start code data only Yellow DMX activity and non zero start code data such as RDM Bottom Power Green Power Red Receive errors ...

Page 7: ...y y Input connector 2 pin screw terminal 1 no y y Input power max 8 W y y Duty cycle 100 25 C y y DC fuse internal resettable fuse for control electronics DMX512 Outputs y y Output mode PSU referenced y y Output isolation n a y y Output ESD protection 10 kV y y Output voltage protection 10 V DMX512 Input y y Input mode Optically isolated y y Input isolation 1 kV y y Input ESD protection 12 kV Cont...

Page 8: ...es in connection with the furnishing performance or use of this material All trademarks are acknowledged Artistic Licence Engineering Ltd Compliance railSplit dmx is CE UKCA compliant when installed in a shielded and earthed metal case Compliance All Products manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE UKCA and RoHS regulations Product speci...