background image

August  30,  2012 

Ver1.11 

 
 

USB2.0 CMOS CAMERA 

 

ARTCAM-MI Series 

 

INSTRUCTION BOOKLET 

 

0.36M pixels 

ARTCAM-036MI2 Series 

1.3M pixels 

ARTCAM-130MI Series 

3.0M pixels 

ARTCAM-300MI Series 

5.0M pixels 

ARTCAM-500MI Series 

9.0M pixels 

ARTCAM-900MI Series 

10.0M pixels 

ARTCAM-1000MI Series 

 

 

 

 

 

 

 

 

ARTRAY CO., LTD. 

Summary of Contents for ARTCAM-036MI2 Series

Page 1: ...RTCAM MI Series INSTRUCTION BOOKLET 0 36M pixels ARTCAM 036MI2 Series 1 3M pixels ARTCAM 130MI Series 3 0M pixels ARTCAM 300MI Series 5 0M pixels ARTCAM 500MI Series 9 0M pixels ARTCAM 900MI Series 10 0M pixels ARTCAM 1000MI Series ARTRAY CO LTD ...

Page 2: ... 2 Contents 1 Attention 3 2 Introduction 6 3 Main Features 6 4 The Product 7 5 Connect the Camera 8 6 Specifications 9 7 External Dimensions 13 8 External Trigger 16 9 Recommended PC 20 ...

Page 3: ...nded 8 Please contact us if you find any unclear points or mistakes in this manual 9 Quoting copying or altering some or all parts of the manual without our permission is prohibited 10 We are not responsible for any lost or damages on your profits due to the use of our products 11 Please understand that our oversea branches do not provide maintenance or repair services About the Icons To keep the ...

Page 4: ...mperature may cause damages to the camera or even cause fires Do not cover the product with cloth or other materials The product may get extremely hot and the heat may cause deformations on the parts or even cause fires Please avoid dropping or shocking the product as the product may be damaged Do not touch the cable with a wet hand Such action may cause electric shocks Please avoid continuously c...

Page 5: ...e after the purchase and thus cause the need to apply export licenses The 27 white countries not under the UNSCArms Embargo Argentina Australia Austria Belgium Bulgaria Canada Czech Republic Denmark Finland France Germany Greece Hungary Ireland Italy Republic of Korea Luxemburg Netherlands New Zealand Norway Poland Portugal Spain Sweden Switzerland United Kingdom and United States About the Japane...

Page 6: ...C Mount board type cameras For ARTCAM 036MI2 130MI 500MI series monochrome and near infrared types are also available upon your choice ROI Region Of Interest One major benefit of CMOS sensor is the ROI function which enables readout of designated partial images with a faster transmission speed Sub sampling function This function results in a more pleasing output image with reduced subsampling arti...

Page 7: ...refers to create their own image processing software or use our camera with other applications we provide SDK upon requests 4 The Product 1 Camera 2 USB Cable MI series One end of the cable integrated to the camera 1 8m approx Board Type TypeAUSB cable 1 8m approx 3 Instruction Booklet 4 Viewer software Device Driver CD Options 1 C Mount lens 2 2 Measurement Filing Software ART MEASURE 3 Recording...

Page 8: ... Time 1 17991 1 033sec Exposure Time Shutter Valuex 1280 234 180 x0 0417 μsec 1280x1024 pixels at 24MHz 300MI Series Range 1 16383 Exposure Time 1 9760 1 679sec Exposure Time Shutter Valuex 2048 411 x0 0417 μsec 2048x1536 pixels at 24MHz 500MI Series Range 1 16383 Exposure Time 1 8702 2 173sec Exposure Time Shutter Valuex 2592 592 426 x0 0417 μsec 2592x1944 pixels at 24MHz 900MI Series Range 1 819...

Page 9: ... P0 5 130MI OP C Mount 300MI 300MI OP CM Board Lens MountM12 P0 5 300MI OP Power DC5V Supplied by USB port Power Consumption UnderApprox 2W Ambient Conditions OperatingTemperature Humidity 0 35 C 10 80 Noncondensing StorageTemperature Humidity 0 60 C 10 95 Noncondensing External Dimensions 50 W x47 H x59 4 D mm 036MI2 43 5 W x43 5 H x25 7 D mm 036MI2 OP 50 W x47 H x27 1 D mm 036MI2 OP CM Lens trip...

Page 10: ...00MI OP C Mount 1000MI 1000MI OP CM Board Lens MountM12 P0 5 1000MI OP Power DC5V Supplied by USB port Power Consumption UnderApprox 2W Ambient Conditions OperatingTemperature Humidity 0 35 C 10 80 Non condensing StorageTemperature Humidity 0 60 C 10 95 Noncondensing External Dimensions 50 W x47 H x59 4 D mm 500MI 43 5 W x43 5 H x25 7 D mm 500MI OP 50 W x47 H x27 1 D mm 500MI OP CM Lens tripod cab...

Page 11: ... BW 500MI BW OP CM Board Lens MountM12 P0 5 500MI BW OP Power DC5V Supplied by USB port Power Consumption UnderApprox 2W Ambient Conditions OperatingTemperature Humidity 0 35 C 10 80 Non condensing StorageTemperature Humidity 0 60 C 10 95 Noncondensing External Dimensions 50 W x47 H x59 4 D mm 036MI2 BW 43 5 W x43 5 H x25 7 D mm 036MI2 BW OP 50 W x47 H x27 1 D mm 036MI2 BW OP CM Lens tripod cablen...

Page 12: ...0MI NIR OP CM Board Lens MountM12 P0 5 500MI NIR OP Power DC5V Supplied by USB port Power Consumption UnderApprox 2W Ambient Conditions OperatingTemperature Humidity 0 35 C 10 80 Non condensing StorageTemperature Humidity 0 60 C 10 95 Noncondensing External Dimensions 50 W x47 H x59 4 D mm 036MI2 NIR 43 5 W x43 5 H x25 7 D mm 036MI2 NIR OP 50 W x47 H x27 1 D mm 036MI2 NIR OP CM Lens tripod cableno...

Page 13: ... 13 7 External Dimensions 7 1 C MOUNT CASED USB CABLE TYPE ARTCAM 036MI2 036MI2 BW 036MI2 NIR ARTCAM 130MI 130MI BW 130MI NIR ARTCAM 300MI ARTCAM 500MI 500MI BW 500MI NIR ARTCAM 900MI ARTCAM 1000MI ...

Page 14: ...14 7 2 BOARD LENS BOARD TYPE ARTCAM 036MI2 OP 036MI2 BW OP 036MI2 NIR OP ARTCAM 130MI OP 130MI BW OP 130MI NIR OP ARTCAM 300MI OP ARTCAM 500MI OP 500MI BW OP 500MI NIR OP ARTCAM 900MI OP ARTCAM 1000MI OP ...

Page 15: ...ARD TYPE ARTCAM 036MI2 OP CM 036MI2 BW OP CM 036MI2 NIR OP CM ARTCAM 130MI OP CM 130MI BW OP CM 130MI NIR OP CM ARTCAM 300MI OP CM ARTCAM 500MI OP CM 500MI BW OP CM 500MI NIR OP CM ARTCAM 900MI OP CM ARTCAM 1000MI OP CM ...

Page 16: ... 16 8 External Trigger 8 1 Trigger Input ARTCAM 036MI2 130MI 300MI 500MI series are designed with external trigger Trigger Input Circuit R1 2 4kΩ R2 10kΩ R2 TRIG 3 3V CPLD Camera R1 BNC PC814 ...

Page 17: ...gger for next frame Approximate 100H after the Vertical Synchronization Signal transits to a low voltage ForARTCAM 036MI2 the image will be acquired when the trigger signal transits from a low voltage to a high one If the trigger signal stays at a high level the trigger time cycle will repeat automatically and image will be acquired continuously ImageTransfer USB t0 t1 t5 t3 t4 t2 Vertical Synchro...

Page 18: ... Subject to ROI Settings and Operation Clock t5 Effective Trigger for next frame Approximate 100H after the Vertical Synchronization Signal transits to a low voltage ForARTCAM 130MI 300MI the image will be acquired only when the trigger signal transits from a high voltage to a low one If the trigger signal stays at a high level or at a low level no image will be acquired ImageTransfer USB Vertical...

Page 19: ...gger for next frame Approximate 100H after the Vertical Synchronization Signal transits to a low voltage ForARTCAM 500MI the image will be acquired when the trigger signal transits from a low voltage to a high one If the trigger signal stays at a high level the trigger time cycle will repeat automatically and image will be acquired continuously Trigger Input TRIGSignal ResetTime 1st Line 2nd Line ...

Page 20: ...sferred USB2 0 hardware such as Memory stick External HDD External DVD CDROM and etc Especially if the PC adopts a Cypress control chip it may not recognize the later connected bulk transfer device if the device is connected when the Artray camera is in function This issue is hard to be solved because the problem is on the lower firmware of the control chip and the PC bios As a solution we recomme...

Reviews: