background image

AIR CONDITIONING TOOL

CORDLESS VACUUM PUMP1.5CFM

【Read through this manual carefully before using the pump.】

INSTRUCTION MANUAL

Summary of Contents for 1.5CFM-BL

Page 1: ...AIR CONDITIONING TOOL CORDLESSVACUUMPUMP1 5CFM Read through this manual carefully before using the pump INSTRUCTION MANUAL ...

Page 2: ...the specifications stated in your order Check the overall pump for any damage or deformation caused in transit due to accidents or other reasons Check that all items and accessories delivered In case any discrepancy is found immediately report the fact to the shop you purchased or our sale office The contents of this manual are subject to change without prior notice CLASSIFICATION OF CAUTIONS WARN...

Page 3: ...ions In Use 16 Cooling System 16 Conditioning Charge 17 To Maintain Battery Life 17 Inspection Repair Storage Of Charger 17 Installing Removing Battery Cartridge 18 OPERATION 19 Adding Oil 19 Checking Performance 19 Operation evacuation work 20 Exchanging Battery Cartidge 21 Operation Times guideline 21 MAINTENANCE INSPECTION 22 Checking The Oil 22 Replacing The Oil 22 Cleaning The Pump 23 Trouble...

Page 4: ...rt becomes hot and it may lead to burn injury Wear protective glasses and gloves during operation Avoid contact with refrigerant blindness and injuries may result to operator The power source should be AC220 240V If the power source is not correct it may lead to heating smoking or fire See the specification in this instruction manual Do not operate the pump in rain or with wet hands Operation in r...

Page 5: ...ell ventilated area especially in a small space Otherwise an accidental lack of oxygen or poisoning may happen Use or store the pump on a horizontal position The oil may leak and it may lead to accident Be careful about oil leakage Make sure no vacuum pump oil leaks Failure to do so may result in fire Always switch off the pump before installing of the battery cartridge Installing of the battery c...

Page 6: ...njury Ask for repairs if smothing is wrong such as body is abnormally hot Do not alter a pump as this is adapted for relevant safety standard Other safety caustions Check the damage on a pump Before operation check damage on a battery cartridge and other parts Check if pump works correctly and perfome prescribed function If something is wrong do not use a pump and ask for repairs Stop operation im...

Page 7: ...box fabric carpet vinyl etc Do not cover windhole of charger during charging Also do not insert metal objects and flammable into windhole Do not charge a battery cartridge where there is much dust A charger has a charging terminal in a battery cartridge installing part Foreigh substances such as metal objects and water should be away from charger It may lead to smoke fire and explosion Do not use ...

Page 8: ... fire Do not charge a battery cartridge where ambient temperature is lower than 10 or higher than 40 It may lead to explosion and fire Charge a battery cartridge in a well ventilated area Do not cover a battery cartridge and charger with fabric It may lead to explosion and fire When not in use disconnect the charger plug from power outlet It may lead to explosion and fire Always drain your vacuum ...

Page 9: ...ident Keep your work bench and area tidy and well lit Bad working conditions invite accidents Do not operate the pump when you cannot concentrate on your work due to fatigue drinking medication and so on When not in use the pump should be stored in dry and high or locked up place out of reach of children Use only the accessories or attachments given in this manual and our catalogs Otherwise it wil...

Page 10: ...UM PUMP 1 5CFM 9 COMPONENTS OF THE MACHINE Main Parts Motor Oil tank Oil fill exhaust cap 1 5CFM B Base Intake shut off valve Handle Battery holder Sight glass Battery cartridge LED lamp Power switch Oil drain plug ...

Page 11: ...ible to achieve the final vacuum level requested Big sight glass and low oil level design avoids running without oil and ensures reliable usage Besides the check valve avoids any oil mixture due to the backflow after a power interruption or any other process interruption Symbols The following show the symbols used for the equipment Be sure that you understand their meaning before use Warning hot s...

Page 12: ...07 Ball valve S with vacuum gauge VP051 5 16 charging hose with ball valve A I 1 5 4 Battery charger DC18RC 220V 240V VP053 China 220V 240V VP054 Hong kong Singapore Malaysia 110V VP055 Taiwan 220V 240V VP056 Vietnam India Thailand Indonesia Philippines Chile Peru 220V VP057 Korea 100V 120V VP058 Mexico Colombia Panama 100V 240V VP059 Brazil 18VBattery BL1850B VP060 China VP049 Hong kong Singapore...

Page 13: ...ion stop using the battery cartridge and remove it and cool down or charge it The remaining battery capacity is too low and the tool will not operate In this situation remove and recharge the battery cartridge Battery cartridge without a star marking The pump is operated in a manner that causes it to draw an abnormally high current In this situation turn the pump off and stop the application that ...

Page 14: ...ody sound and buzzer sound a long beep comes out to notify completion of charge Battery cartridge will be cooled down if it is kept installing Charging time varies by temperature 10 40 that battery cartridge si charged at and conditions of the battery cartridge such as battery cartridge which is new or has not been used for a long period of time If the battery cartridge is not used immediately aft...

Page 15: ...melody sound comes out leave the battery cartridge being inserted and the charge will begin When a short beep mde is selected no completed charging signals comes out Silent Mode With finish of charge the green light remains lit with the red light going out and the melody sound preset at the insertion of the battery cartridge or buzzer sound a loong beep comes out to notify completion of charge In ...

Page 16: ...CORDLESS VACUUM PUMP 1 5CFM 15 Charging Indication Lamps The detail of charging indicator lamps is as follow ...

Page 17: ...battery Green light does not blink after installing plug of charger into proper power outlet Red light does not blink or light up after installing battery cartridge The battery is not charged in more than one hour after start charging with led light lights up This charger is equipped with cooling fan for heated battery in order to enable to prove its own performance Sound of cooling air comes out ...

Page 18: ...ttery Life Charge the battery cartridge when cannot get enough power from a pump Do not recharge full charged battery cartridge Charge the battery under the condition of ambient temperature is 10 40 Cool down and charging by installing the battery into charger which gets hot immediately after use is recommended In case of battery is not in use for long time more than 6 months storing charged batte...

Page 19: ...ry cartridge with the groove in the housing and slip it into place Insert it all the way until it locks in place with a little click If you can see the red indicator on the upper side of the button it is not locked completely Red part Battery cartridge Button 2 1 Always install the battery cartridge fully until the red indicator cannot be seen If not it may accidentally fall out of the pump causin...

Page 20: ...The pump does not contain oil when newly purchased Refer to Adding oil and add oil Checking Performance Connect the low side valve of the manifold and the intake port of the pump with a charging hose Close the low side valve of the manifold Open the intake shut off valve Open the inlet valve Turn the pump on If the pressure of the manifold indicates a vacuum of 0 09 to 0 1 MPa within 30 seconds th...

Page 21: ...or less In these cases bring the pump indoors and allow it to warm up Open the intake shut off valve of the pump and the low side valve of the manifold When the specified degree of vacuum refer to the manual provided by the air conditioner manufacturer is reached close the low side valve of the manifold Close the intake shut off valve and turn the pump off The pump becomes hot during operation and...

Page 22: ...e pump is turned off remove the battery and charge it or replace it with a spare battery After finishing work remove the battery and attach the supplied cover Note When transporting operating and storing the tool never place it on its side or upside down This may cause oil leakage from the oil fill exhaust cap Leave the pump and manifold for 5 minutes or more If the pressure of the manifold does n...

Page 23: ... Inspect and clean regulary as instructed below and perform correction or replacement timely Stop the pump To make pump life longer and smooth start up these procedures to shut off pump should be followed 1 Close the manifold valve between the pump and the system 2 Remove the hose from the pump inlet Cover the inlet port opening to prevent any contamination or foreign particles from entering the p...

Page 24: ...Condition Possible Cause Solution The pump will not start 1 The battery is not set properly 2 The ambient temperature is too low 3 Poor wiring connection 4 The pump is locked 5 Motor failure 1 Set the battery properly 2 Warm up the pump in doors 3 Repair 4 Repair 5 Repair The pump will not enough vacuum 1 Leaking from the system 2 Insufficient oil 3 Dirty oil 4 Pump parts are worn out 5 Damaged fi...

Page 25: ...D MOTO AS Yellow Green Circuit board Red Power switch Black Red Motor M 18V 18V AS terminal AS Black We acting in sole responsibility declare that this product complies with the regulation of the directives 2006 42 EC 2014 30 EU 2011 65 EU For additional information please contact us or one of the subsidiary companies ...

Page 26: ...ting to electromagnetic compatibility It confirms that the listed apparatus complies with all essential requirements of the directive and is based on the technical specifications applicable at the time of issuance It refers only to the particular sample submitted for testing and certification See also notes overleaf Test report no 4852016229500 Date After preparation of the necessary technical doc...

Page 27: ...CORDLESS VACUUM PUMP 1 5CFM 26 ...

Page 28: ...ver 02 Code No IM0400 A ...

Reviews: