Installation, Operation and Maintenance Instructions 

 

Model FSPO

 

 

Description  and  Specifications:   

The  Model  FSPO  is  a  close-coupled,  end  suction,  single  stage,  open  impeller,  back 

pullout centrifugal pump.  Connections are NPT threaded.  All wetted  metal pump parts are 304SS or better.  Most parts 
are  forged  from  stainless  steel  sheet.    The  seal  plate  is  made  of  fiberglass  reinforced  Ryton.  Standard  O-rings  and 
elastomeric  seal  parts  are  Buna.    Viton  and  EPR  are  optional.      Motors  are  NEMA  56J  frame,  with  a  C-Face  mounting 
flange and a threaded shaft.  All pumps use a mechanical seal to prevent leakage around the motor shaft.   
 

Operating limits:  

The model FSP is designed for a maximum pressure of 50 PSIG, at a maximum temperature limit of 

212F.   Motor is limited to 20 starts per hour, evenly distributed. 
 

Notice:  Upon receipt of this equipment, inspect the  carton and the equipment for any damages that might have 
occurred  during  shipment  and  notify  the  carrier  immediately.

    Damage  that  occurs  during  shipment  is  not  the 

responsibility of American Stainless Pumps.  Failure to notify the carrier will place responsibility on the purchaser for any 
repairs or damages occurring during shipment. 

 

Safety  Instructions:  To  avoid  serious  or  fatal  injury  and/or  property  damage,  read  and  follow  all 
instructions  in  this  manual.    Review  all  instructions  and  warnings  included  in  this  manual  before 
attempting any work on this pump or pump/motor assembly.  Do not remove or alter any decals.

 

 

The  motor  used  to  drive  this  pump  is  an  electrical  device  connected  to  a  potentially  lethal  voltage 
power source.  Take all precautions required when working with or on the motor and its power source, 
including but not limited to: 

1. 

Always  disconnect  and  lockout  the  electrical  power  source  before  attempting  any  connection,  maintenance  or 

repairs.  Failure to do so can cause electrical shocks, burns and death. 
2. 

Install, ground and wire motors in accordance with all local and national electrical codes. 

3. 

Install an all leg disconnect switch near the motor for quick access. 

4. 

The electrical supply must match the motor nameplate specifications and the motor must  be wired per the wiring 

diagram  on  the  motor  to  match  the  selected  voltage.   

Incorrect  wiring  can  cause  fire  and  motor  damage  and  will 

void the warranty. 

5. 

Most single phase motors and some three phase motors will have automatic thermal protection switches wired in 

the motor.  These switches will open and stop the motor if the motor overheats.  As the motor cools, these switches will 
close and start the motor automatically and unexpectedly.   
6. 

Motors  that  do  not  have  thermal  overloads  must  have  a  properly  sized  contactors  or  magnetic  starters  and 

overload switches (or fuses) in the starter panel.  Three phase motors require all leg protection. 
7. 

Use only stranded copper wire  to motor and ground.  Wire size must limit the maximum voltage drop to 10% of 

the motor nameplate voltage at the motor terminals. 
8. 

Three  phase  motors  can  rotate  in  either  direction.    The  pump  will  operate  properly  only  in  one  direction 

(clockwise when looking from the motor end, counter-clockwise when viewed from the pump end). 

 Operating the pump 

in the reverse rotation may damage or destroy the pump and motor and voids the warranty

.   

 

Installation: 

-Locate the pump as near to the liquid source as possible.  The pump must be primed with little or no air in the case to 
begin operation.  The pump must be located below the liquid level when starting.  This pump is not self priming. 
-Protect  the  pump  and  motor  from freezing.    Although  the  pump may  survive  a  freeze  up,  the  mechanical  seal  and  O-
Rings will not. 
-Allow adequate space around the unit for service and ventilation. 
-Units may be installed horizontally, at an angle or vertically with the motor on top.  

Do not mount the motor below the 

pump as leakage from the pump will damage the motor and can cause a shock, burns or death. 

-Units  mounted  horizontally  should  be  located  on  a  flat,  rigid  surface.    Unit  may  be  free  standing,  but  some  vibrations 
may occur.  If attached to a foundation, tighten hold down bolts before connecting the piping. 
 
 
 
 

 
 

 

 

 

 

 

 

 

 

 

 

 

Page 1 of 5 

 

Summary of Contents for FSPO

Page 1: ... local and national electrical codes 3 Install an all leg disconnect switch near the motor for quick access 4 The electrical supply must match the motor nameplate specifications and the motor must be wired per the wiring diagram on the motor to match the selected voltage Incorrect wiring can cause fire and motor damage and will void the warranty 5 Most single phase motors and some three phase moto...

Page 2: ...ation Pump must be completely primed before starting Air in the suction lines or case must be vented Do not operate the pump at or near zero flow At zero flow heat will build up in the pump and can cause extreme damage to the pump property damage and or possible injury to operating personal Minimum flows of 10 of the pumps best efficiency point are recommended unless otherwise authorized by ASP Do...

Page 3: ...impeller only If the rotating element does not come off easily it is stuck to the shaft Use channel lock pliers or a screwdriver to pry the element off the shaft 9 Remove the seal plate It should come off without force If you plan to replace the stationary seat you will need to press it out from the back Do not push with your finger as you will probably cut it on the edges of the seal plate when t...

Page 4: ... the hub behind the impeller you should get a total thickness of about 0 900 inches This impeller thickness will require a washer spacer pack of approximately 50 mils to get a factory clearance of 10 mils A larger or smaller impeller thickness will require fewer or more washer spacers Always check to make sure the impeller is not rubbing on the case prior to turning on the motor Turn shaft by hand...

Page 5: ...ss Pumps Stainless Steel Pumps for the Commercial Marketplace www aspumps com 14032 S Avalon Blvd Los Angeles CA 90061 Phone 310 630 8089 Fax 310 630 8095 Model FSP Exploded View doc 11 29 2011 Model FSP Exploded View ...

Reviews: