Designed for installation inside casing of minisplit evaporator, 

above ceiling or inside lineset cover / Diseñada para instalarse 

dentro del gabinete del evaporador, encima de techo falso o en el 

cubierta de tuberÌa de cobre

 

Quick and easy to install / Rápido y fácil de instalar

 

Quietly and reliably pump condensate to a maximum

height of 33 feet / Bombean el aqua de condensacion hasta una 

altura máxima de 33 pies de manera silenciosa y confiables

mini aqua 

pump/bomba

INSTALLATION & MAINTENANCE MANUAL / MANUAL DE INSTALACION Y MANTENIMIENTO

Manufactured by: Aspen Pumps  Apex Way  Hailsham  East Sussex BN27 3WA  United Kingdom  
website: www.aspenpumps.com

Product Warranty 

The manufacturer disclaims all implied and express warranties, including the implied warranty of merchantability and the implied warranty of fitness for a particular purpose, 

except as follows: This condensate product purchased by you concurrently is unconditionally warranteed to be free from defects in material and workmanship under normal use for a period of two years 

from date of purchase, providing it is installed and operated strictly in accordance with the manufacturer’s installation instructions. If the product is found to be defect or otherwise fails in normal use, you 

may return it for replacement. All freight charges for the return of the product shall be borne by you. The manufacturer will pay outgoing freight charges for the replacement product. Defective product 

returned to the factory prepaid will be repaired or replaced free of charge. Replacement product will, to the extent such product is then available in the manufacturer’s inventory, be of a similar type of 

color and kind. Manufacturer retains the right to substitute product if the replacement product does not conform in terms of color, type and specifications to the original product if no longer available. 

This warranty does not cover replacement labor or any cost, claim or incident to any defect nor does it cover any consequential damages. The sole liability of the manufacturer under this warranty is 

limited to the replacement of defective product. Product damaged by improper use, accident, neglect, alteration, abuse or improper installation is excluded from this warranty.

Thank you for buying your new Mini Aqua Pump

 

This manual provides complete instructions for installation 

and maintenance which should be carefully followed. Please record following information for future reference: 

Agradecemos su compra de la nueva bomba Mini Aqua. 

 Éste manual proporciona las instrucciones completas 

que deben de seguirse cuidadosamente para la correcta instalación y mantenimiento de la bomba. Anote la 

información siguiente para una referencia futura.

Serial number: 

Operating voltage:

Numero de serie: 

Voltaje operativo:                

Date installed:    

Location of pump:   

Fecha de instalación: 

Ubicación de la bomba:

Imported and Distributed by: / Importado y distributado para:
2601 Spenwick Drive, Houston, TX 77055  Tel: 800-231-3345  Fax: 800-441-0051  www.rectorseal.com

Summary of Contents for mini aqua pump

Page 1: ...ht charges for the replacement product Defective product returned to the factory prepaid will be repaired or replaced free of charge Replacement product will to the extent such product is then available in the manufacturer s inventory be of a similar type of color and kind Manufacturer retains the right to substitute product if the replacement product does not conform in terms of color type and sp...

Page 2: ...ISE LEVEL IS PRESENT THE SOUND OF THEIR INTERMITTENT OPERATION MAY STILL BE PERCEIVED AS NOISY AND THE PUMP MAY HAVE TO BE SITED OUTSIDE THE SENSITIVE AREA ALWAYS CONFIRM ACCEPTABLE NOISE LEVEL BEFORE INSTALLING ANY CONDENSATE PUMP IN A BEDROOM OR OTHER NOISE SENSITIVE AREA CONSULT RECTORSEAL FOR FURTHER INFORMATION AND FOR DETAILS OF ALTERNATIVE PUMPING METHODS PH 713 263 8001 800 231 3345 FAX 71...

Page 3: ...he Discharge Hose Installation Guide on page 16 17 Note for Silent models The ASD should be installed at the end of the silicone tubing connected to the mini pump and be used as the transition to I D vinyl tubing PREVENCIÓN DEL SIFONAJE Si el extremo de la manguera de descarga está por encima del nivel de la cubeta de drenaje en el evaporador no puede haber sifonaje y las medidas de antisifonaje n...

Page 4: ...tube is above maximum water level in drain tray NOTE BREATHER TUBE IS CRITICAL TO CORRECT OPERATION OF PUMP AND MUST REMAIN IN PLACE AND FREE OF RESTRICTIONS AT ALL TIMES Encaje el tubo respirador en la tapa del depósito segurese que el tope del tubo este sobre el máximo nivel de agua en la bandeja de desagüe NOTA EL RESPIRADERO ES CRÍTICO PARA EL FUNCIONAMIENTO CORRECTO DE LA BOMBA Y DEBE PERMANE...

Page 5: ... as per detailed wiring diagram from our website If no alarm is required isolate orange wire with a wirenut Some evaporators provide numbered terminals for connection of the gray and purple overflow alarm wires directly into the PCB refer to relevant factory approved diagrams for correct wiring instructions Most VRF systems e g City Multi ECO I VRF III and Multi V require constant communication be...

Page 6: ... DE FÁBRICA PARA LAS CORRECTAS INSTRUCCIONES DE ALAMBRADO Y O CONEXIONADO THESE ARE GENERIC DIAGRAMS FOR REFERENCE PURPOSES ONLY AS WIRING PROTOCOLS VARY FROM ONE MINISPLIT MANUFACTURER TO ANOTHER FACTORY APPROVED WIRING DIAGRAMS FOR MOST MODELS OF ALL MAJOR MINISPLIT BRANDS CAN BE FOUND ON OUR WEBSITE AT www rectorseal com or call 1 800 231 3345 for onsite assistance ÉSTOS SON DIAGRAMAS GENÉRICOS...

Page 7: ... from resting on the reservoir bottom This may occur if pump has been operated for some time without cleaning Clean with an anti bacterial cleansing solution NOTE The pump will only switch off when the float is actually resting on the bottom of reservoir 4 Does evaporator produce more condensate than pump can handle If so pump is too small and must be replaced with a different type Fault Vibration...

Page 8: ...ry Because of this they will emit a clicking noise which is entirely normal during the initial start up phase only usually around 10 seconds or less and this will stop when all of the air in the pump intake has been purged and the pump becomes cooled and lubricated by the water flowing through it IF THE CLICKING NOISE IS HEARD WHILE THE PUMP IS OPERATING AFTER THE INITIAL START UP HAS BEEN COMPLET...

Page 9: ... que toda el agua en el sistema haya sido evacuada por si sola NOTAS IMPORTANTES EL USO DE UNA MANGUERA DE DESCARGA DE TAMAÑO DIFERENTE AL TAMAÑO ESPECIFICADO DI PUEDE REDUCIR EL RENDIMIENTO LA INSTALACIÓN CORRECTA DEL DISPOSITIVO ANTISIFONAJE SUMINISTRADO ELIMINARÁ EL SIFONAJE Y REEMPLAZARÁ EL ESCAPE DE AIRE DE LA MANERA INDICADA EN LA PÁGINA 4 Gua para la Instalación de la Manguera de Descarga E...

Page 10: ...rcionar el máximo nivel de protección contra el desbordamiento así como para garantizar que la instalación cumple con el código Aunque puede que este código aún no haya sido aplicado en todas las áreas ES MUY RECOMENDABLE QUE SE INSTALE OTRO INTERRUPTOR DE AUTO EVACUACIÓN DE DESBORDAMIENTO EN TODOS LOS EVAPORADORES MINISPLIT INCLUYENDO AQUELLOS QUE TIENEN BOMBAS MONTADAS EN LA FÁBRICA O BOMBAS DE ...

Page 11: ...ito Tubo Respirador La Bandeja de Desagüe El Depósito Tubo Respirador 1 La bandeja de desagüe se llena con agua la cual fluye hacia el depósito La manguera de entrada entre el depósito y la bomba está vacía y llena con aire 2 El nivel de agua levanta el flotador activando la bomba la cual se auto purga por la succión de agua del depósito Durante este período la bomba está operando caliente y seca ...

Page 12: ...rga la presión atmosférica esta igualada en ambos extremos de la manguera del sistema por eso el efecto sifón no podrá presentarse y LA MANGUERA DE ENTRADA PERMANECE LLENA CON AGUA 4 La bandeja de desagüe otra vez se llena con agua la cual fluye al depósito y activa la bomba LA MANGUERA DE ENTRADA YA ESTA LLENA CON AGUA de allí que no sea succionado aire y la bomba es inmediatamente enfriada y lub...

Page 13: ...Mini condensate pumps Novent Locking refrigerant caps Big Foot AC rooftop mounting system RectorSeal AC equipment mounting Slimduct Condensate drain hose RectorSeal 2601 Spenwick Drive Houston TX 77055 ph 713 263 8001 800 231 3345 fax 713 263 7577 800 441 0051 www rectorseal com Like Us on Facebook Scan for more info BRLDK 4 2013 961890 ...