INSTALLATION INSTRUCTION

FWB SERIES HYDRONIC VERTICAL WALL MOUNT AIR

HANDLER

IMPORTANT MASSAGE TO INSTALLER:

 "The United States Environmental Protection Agency ("EPA") has issued

various regulations regarding the introduction of disposal of refrigerants in this unit. Failure to follow these regulations
may harm the environment and can lead to the imposition of substantial fines. Because these regulations may vary
due to the passage of new laws we suggest that any work on this unit be done by a certified technician. Should you
have any questions please contact the local office of EPA." Some Aspen coils may include a Schrader valve on the
suction manifold. During installation, this Schrader valve must be protected from heat or it may leak.
All Aspen coils are shipped with a nitrogen holding charge. DO NOT install the coil if this charge is not present.

IMPORTANT MESSAGE TO OWNER:

 These instructions should be carefully read and kept near product, for future

reference. While these instructions are addressed primarily to the installer, useful maintenance information is included.
Have your installing dealer acquaint you with the operating characteristics of the product and periodic homeowner
maintenance requirements. As expressed in our product warranty, Aspen will not be billed for any structural damage
due to failure to follow these installation requirements. Once installed, Aspen coils may contain chlorofluorocarbons
(CFC's) or hydrochlorofluorocarbons (HCFC's). Under certain conditions, CFC's & HCFC's may pose a health risk.
Please notify a licensed service technician immediately if you suspect your system may contain a leak.

CODES AND REGULATIONS

This product is designed and manufactured to permit installation in accordance with National Codes. It is the installer’s
responsibility to install the product in accordance with National Codes and/or prevailing local codes and regulations.
The manufacturer assumes no responsibility for equipment installed in violation of any code or regulation.

INSPECTION

This product has been inspected and run tested at the factory and released to the transportation agency without known
damage. Inspect exterior of carton for evidence of rough handling in shipment. Unpack carefully, if damage is found,
report immediately to the transportation agency.

REPLACEMENT PARTS

Order all replacement parts through your local distributor. When ordering parts, give complete model and serial
number as shown on the unit rating plate.

Summary of Contents for FWB SERIES

Page 1: ...th the operating characteristics of the product and periodic homeowner maintenance requirements As expressed in our product warranty Aspen will not be billed for any structural damage due to failure to follow these installation requirements Once installed Aspen coils may contain chlorofluorocarbons CFC s or hydrochlorofluorocarbons HCFC s Under certain conditions CFC s HCFC s may pose a health ris...

Page 2: ... Screws or nails must be used to secure the unit in place The platform must provide ample clearance for drain lines that exit the unit from the bottom The fan coil can be installed in a partition wall as shown in Figure 1 A louvered wall panel or perforated door made by the coil manufacturer must be used with this type of installation The fan coil is installed before the drywall and louvered panel...

Page 3: ...he fan coil and water heater connections two valves provided by the installer must be installed to permit purging of air in the system and also to allow the hot water coil in the unit to be separated from the house water system during servicing PURGING THE SYSTEM 1 Open air vent and allow water heater to fill with water Close air vent when water heater is full and all air has been purged 2 Ignite ...

Page 4: ...purged of air Purge the system again as described earlier T P VALVE ON WATER HEATER WEEPS This normally occurs when a backflow preventer has been installed in the cold water line supplying the water heater An expansion tank may be necessary to correct the problem Contact a qualified plumbing professional for assistance HOT WATER IS CIRCULATING THROUGH THE HEATING COIL DURING THE COOLING CYCLE The ...

Page 5: ...ter a To determine water heater GALLON CAPACITY A minimum 40 gallon high recovery and or high efficiency gas or oil fired water heater is recommended The following volume sizing guide is satisfactory in most areas of the country 600 800 CFM air handlers minimum 40 gallon water heater 1000 1200 CFM air handlers minimum 50 gallon water heater 1400 1600 CFM air handler either two 40 gallon water heat...