Page 2: ... implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agents be liable for any indirect special incidental or consequential damages including damages for loss of profits loss of business loss of data interruption of business and the like even if ASRock Rack ...

Page 3: ...hen removal of the chassis lid required for servicing Turn off power and unplug any power cords cables and Reinstall the chassis lid before restoring power Important Safety Instructions Pay close attention to the following safety instructions before performing any of the operation Basic safety precautions should be followed to protect yourself from harm and the product from damage Operation of the...

Page 4: ...anel 6 2 5 Front Control Panel Buttons and LEDs 7 Chapter 3 Hardware Installation and Maintenance 9 3 1 Server Top Cover 10 3 2 Hard Drive 12 3 3 System Fan 15 3 4 Server Board 16 3 5 Add in Card 17 Chapter 4 Chassis Cables 19 Chapter 5 Board Specifications 21 5 1 Front Panel Board FPB 21 Appendix A 22 Installing the CPU AMD AM4 Socket 22 Installing the CPU Heatsink 24 Installation of Memory Modul...

Page 5: ...specifications might be updated the content of this documentation will be subject to change without notice In case any modifications of this documentation occur the updated version will be available on ASRock Rack s website without further notice If you require technical support related to this product please visit our website for specific information about the model you are using ASRock Rack s We...

Page 6: ...1 Power Supply Unit 1 1 System Fans 3 3 HDD Backplanes BPB 2 0 Front Panel Board FPB 1 1 Fan Cable L 300mm 1 0 Fan Cable L 200mm 0 3 SATA Cable L 300mm 1 1 SATA Cable L 500mm 0 1 USB Cable 0 1 Aux_Panel Cable 0 1 Air Duct 0 1 1U Cooler 1 1 Riser Board 1 1 Slide Rail 1 1 Accessory Box 1 1 Support CD 1 1 If any items are missing or appear damaged contact your authorized dealer ...

Page 7: ...EDs System event LED I O Ports 2 x USB 3 2 Gen1 ports 1U2LW X470 1U2LW X570 2L2T 2 x USB 2 0 ports 1U2LW C242 Drive Bay Internal 2 x 3 5 HDD carriers Slim ODD option System Cooling Fan 3 x 4028 PWM FAN W 1 4P CONN Power Supply Type Single PSU Output Watts 315W Efficiency Gold Please be noted that the functions are supported depending on the type of the server board Please refer to the user manual ...

Page 8: ...w This chapter provides diagrams showing the location of important components of the server system 2 1 System Components Server Board Front Controls and Indicators Power Supply Unit 2 x 3 5 HDDs Top Cover 1 x Slim ODD Optional 3 x System Fans ...

Page 9: ...res 9 10 5 1 6 8 7 2 3 4 No From 1 3 5 SATA HDD HDD0 2 Front Panel Board FPB 3 3 5 SATA HDD HDD1 4 Slim Optical Disc Drive ODD optional 5 System Fan 1 6 System Fan 2 7 System Fan 3 8 Power Supply Unit PSU 9 Serverboard 10 PCIE x16 Add in Card ...

Page 10: ...1 x Slim Optical Disc Drive ODD 2 Control Panel Buttons and LEDs 3 2 x USB Ports 2 4 System Rear Panel 3 4 1 2 No Description 1 Power Supply Unit 2 I O Shield depends on the specification of the server board 3 Rear Vent 4 PCI Express Slot for the riser card ...

Page 11: ... the server board System Reset Button When the system is completely unresponsive press the system reset button to reboot the server without shutting it off and initialize the system Power Button Press the power switch button to toggle the system power on and standby sleep modes To remove all power from the system completely disconnect the power cord from the server Status LED Definitions Power LED...

Page 12: ...8 English HDD Status LED Status Description Blinking Yellow HDD access Off HDD idle LAN1 LAN2 LED Status Description Blue Link between system and network or no access Blinking Blue Network access ...

Page 13: ...tions 3 Ground yourself properly before touching any system component A discharge of static electricity may damage components Wear a grounded wrist strap if available Installing Procedures The followings are prerequisite to be installed 3 5 HDD s Power Supply Unit Pre installed System Fans Pre installed Server Board Pre installed The server is not completely powered down when you press the Power b...

Page 14: ...to the chassis 2 Push the top cover toward the rear of the chassis to remove the cover from the locked position 3 Lift up and remove the top cover 1 Before removing the top cover power off the server and unplug the power cord 2 The system must be operated with the chassis top cover installed to ensure proper cooling ...

Page 15: ...1 English Installing the Server Top Cover 2 1 3 3 1 Lower the top cover on the chassis making sure the side latches align with the cutouts 2 Slide the top cover toward the front 3 Secure the top cover with the screws ...

Page 16: ...Installing a Hard Disk Drive into 3 5 Hard Drive Carrier Removing a 3 5 Hard Drive Carrier from the Chassis 1 Release the screws that secure the hard drive carriers to the chassis 2 Lift up and remove the carriers 1 1 1 2 2 HDD0 HDD1 ...

Page 17: ...HDD into the carrier with the printed circuit board side facing down Carefully align the mounting holes in the hard drive and the carrier 2 Secure the hard drive using the screws 3 Place the drive carrier back to the chassis with the screw hole aligned 4 Secure the drive carrier with a screw 1 2 4 3 ...

Page 18: ...to the carrier with the printed circuit board side facing up Carefully align the mounting holes in the hard drive and the carrier 2 Secure the hard drive using the screws 3 Place the drive carrier back to the chassis with the screw hole aligned 4 Secure the drive carrier with screws 1 2 4 3 4 ...

Page 19: ...1U2LW Series 15 English 3 3 System Fan Replacing the Simple Swap Fan 1 Press and hold the clip on the fan 2 Press and hold the clip on the middle fan Fan Mount Mounting Hole ...

Page 20: ...ity 3 4 Server Board Follow the steps below to install the server board to the chassis 1 Hold the server board only by the edges 2 Gently place the server board into the chassis Sit the server board on the server board tray 3 Position the server board in the server system Align mounting holes of the server board to the standoff on the chassis 4 Affix the screws clockwise into the mounting holes in...

Page 21: ...lling the Add in Card power off the server and unplug the power cord Removing the Blanking Plate from the Chassis 1 Remove the screws securing the blanking plate assembly on the chassis Keep the screws for later use 2 Lift up the blanking plate assembly 3 Remove the screw securing the blanking plate on the assembly 4 Slide the blanking plate out sideways 4 3 1 1 2 ...

Page 22: ... a riser card first Please refer to the followings for instructions 1 Install the Add in Card to the assembly 2 Secure the Add in Card to the assembly with the screw 3 Align the assembly with the openings of the chassis 4 Attach the assembly to the cahssis with the screw that was previously set aside 1 2 4 3 4 ...

Page 23: ...d quantity vary depending on the server board that comes with your system 1 SATA Cable SATA 6G 180 180 L 300mm 2 SATA Cable SATA 6G 180 180 L 500mm SATA4 3 Fan Cable FAN MB 4 2 5 SATA HDD Cable 2 5 SATA HDD MB 5 USB Cable FPB MB MB BPB 1U2LW 470 1U2LW C242 HDD 1U2LW X570 2L2T MB BPB 1U2LW 470 1U2LW C242 HDD 1U2LW X570 2L2T ...

Page 24: ...20 English 6 Aux_Panel Cable FPB MB ...

Page 25: ...m Healthy LED SYS_LED 5 Mezz LAN2 LED LAN2_LED 6 Mezz LAN1 LED LAN1_LED 7 HDD Status LED HDD_LED 8 Power Status LED Power_LED 9 Power Button Power_SW 10 Front Panel Header AUX_PANEL Front and Auxiliary Panel Header 16 pin AUX_PANEL1 This header supports multiple functions on the front panel 1 LAN2LED RST_SW LAN2LED SYSLED RST_SW SYSLED LAN1LED HDD_LED PWR_LED PWR_LED LAN1LED HDD_LED PWR_LED PWR_SW...

Page 26: ...22 English Appendix A Installing the CPU AMD AM4 Socket 90o 1 2 ...

Page 27: ...1U2LW Series 23 English 3 ...

Page 28: ...24 English Installing the CPU Heatsink 1 2 ...

Page 29: ...eries 25 English Please be aware of the correct direction when you install the CPU heatsink Make sure the the arrow on the CPU heatsink is pointing to the opposite side of the system fan FAN Air Flow Direction ...

Page 30: ...one correct orientation It will cause permanent damage to the motherboard and the DIMM if you force the DIMM into the slot at incorrect orientation For more information about DIMM installation please refer to the User Manual that comes with the serverboard you use 1 2 3 ...