background image

 

 

 

 

eForce

®

 

Keyless

 

Entry

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 

 

 

 
 

Owner’s

 

Manual

 

&

 

Installation

 

Instructions

 

for

 

Models

 

3090C

 

&

 

3090P

 

 

 

80

0180

351

 

Rev.

 

A

 

Adams

 

Rite

 

Manufacturing

 

Co.

 

260

 

Santa

 

Fe

 

Street

 

Pomona,

 

CA

 

91767

 

Phone:

  

800

872

3267

 

www.adamsrite.com

 

Summary of Contents for Adams Rite eForce 3090C

Page 1: ...Force Keyless Entry Owner s Manual Installation Instructions for Models 3090C 3090P 80 0180 351 Rev A Adams Rite Manufacturing Co 260 Santa Fe Street Pomona CA 91767 Phone 800 872 3267 www adamsrite com ...

Page 2: ...atement 2 Operational Description 3 Operational Specifications 4 Troubleshooting 5 Installation Tools Equipment 6 Door Preparation 7 Spindle Preparation 7 Configure for Lock 8 Handing 10 Mortise Cylinder Installation 11 Limited Warranty 13 i 80 0180 327 Rev A ...

Page 3: ... devices DEFINITIONS Prox Class of contactless card credentials that operate on 125kHz iCLASS Class of contactless card credentials that operate on 13 56MHz Secured State of eForce when the clutch is not engaged preventing lever rotation from retracting latch deadbolt Unsecured State of eForce when clutch is engaged allowing lever rotation to retract latch deadbolt Weigand Communication protocol u...

Page 4: ...e by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Operation with non approved equipment is likely to result in interference to radio a...

Page 5: ...tem will receive the card credential information and will send an unlock signal to the eForce if the credentials are valid 3 The LED will change states from red to green and a short audible tone will be heard to indicate a valid unlock status 4 Rotate the lever to gain entry into the building 5 The lock will return to a secured locked state after the access control system unlock period has expired...

Page 6: ...ler Power 12Vdc 300mA Max 2 White Weigand Data 1 6 Green Weigand Data 0 8 Yellow Green Led Control 4 PIN E Lynx Connector Molex Pin Color Description 1 Violet System Ground 3 Gray Lock Activate 12Vdc 10mA Max Lock Activate Signal 12Vdc 10mA Max N O relay or other isolated source output from access control system that applies 12Vdc to this pin when valid credentials were accepted by the access cont...

Page 7: ...ctions Check the eForce body connection LED not lit in secured state Check that power and Weigand lines are properly connected Credentials not activating lock Check for lock power led should be lit and red when secured Trigger access control system lock activate input If this unlock the lock o Be sure credentials are in system database o Ensure Weigand lines are connected properly o Place card in ...

Page 8: ...n hand tools such as center punch drill gun drill bit Phillips screwdriver pliers flat tip screwdriver pencil ADDITIONAL EQUIPMENT NEEDED Mortise Cylinder 1 to 1 in length range with MS cam Note 1 cylinders require a 1 8 trim ring SUPPLIED PARTS Item Description Qty 1 Mounting Bracket Part 22 9076 1 2 10 32 X 5 8 Phillips Pan Head Screws w Lockwasher 4 3 Spindle 1 4 5 64 Allen Key 1 5 Cylinder Loc...

Page 9: ...cket Item 1 with two 2 each of 10 32 x 5 8 Item 2 pan head screws Fig 2 Fig 2 STEP 2 SPINDLE PREPARATION For 1 3 4 doors For MS1850 Deadbolts 4500 4900 Deadlatches 8000 Series Mortise Exit Devices snap off spindle at third notch as shown in Fig 3 For 2 thick door add one notch Fig 3 For 8600 Concealed Vertical Rod Exit Devices snap off spindle at fourth notch as shown in Fig 4 For 2 thick doors ad...

Page 10: ...insert into latch case with notch on the cam pug aligned with latch case setscrew Tighten setscrew and secure with the two brass cam plug screws Left Hand Reverse LHR Fig 6 Right Hand Reverse RHR Fig 7 CVR Exit Device Application 3090P 01 3090C 01 for 8500 8600 Install Tailpiece adapter on shaft of the vertical rod and fasten with Phillips screw as shown Fig 8 Fig 8 8 80 0180 327 Rev A ...

Page 11: ...ACTUATOR SCREW MS1850 Application 3090P 02 3090C 02 for MS Series Deadbolt Two 2 brass hex head screws and the set screw from the MS1850 will fasten the cam plug to the MS1850 Fig 10 For MS Deadbolt insert Cam Plug into lock case with notch on the cam plug aligned with lock case setscrew Tighten setscrew and secure with the two 2 brass cam plug screws Cam Plug must be positioned below door surface...

Page 12: ...ar In some instances this rotation must be changed to match the device and or hand of the door refer to Handing Setup Chart To change rotation insert a flat screwdriver into the output hub Fig 11 located on the back of the eForce and turn approximately 270 Clockwise or Counter Clockwise This will reconfigure the unit to the opposite rotation HANDING SETUP CHART DEVICE TYPE LEFT HAND REVERSE ROTATI...

Page 13: ...ly lift the back plate off the housing CAUTION There are wires connecting the housing and back plate assembly Handle with care Fig 13 Install Cylinder into housing Secure and fasten with supplied locking ring using locking ring spanner tool Fig 13 Gently place back plate back on housing and secure with eight 8 10 32 x 5 8 screws 11 80 0180 327 Rev A ...

Page 14: ...le into the output hub Mount eForce onto mounting bracket and guide spindle into Cam Plug MS 1850 configuration shown Fig 14 The eForce must sit flush on the door surface Fig 14 Secure with two 2 10 32 x 5 8 screws as shown Fig 15 Fig 15 12 80 0180 327 Rev A ...

Page 15: ... lieu of all other warranties including the implied warranties of merchantability and fitness for use and under no circumstances shall ADAMS RITE be liable for any incidental or consequential damages or losses This warranty covers products as outlined above manufactured from May 1 2003 forward This warranty does not cover damages from such causes as abuse accident neglect fire or freight damage WA...

Reviews: