IMPORTANT:

BEFORE
INSTALLING:

TO DETERMINE

HAND OF

YOUR DOOR:

An improperly installed or incorrectly adjusted door closer may cause 

property

 

damage 

or 

personal injury; 

and will void product warranty.

To avoid personal injury, 

DO NOT DISASSEMBLE THIS DOOR CLOSER BODY. 

Door closers must be securely fastened to a properly reinforced door and frame
with fasteners provided.
Door closers with the “A1” HOLD OPEN ARM option are not permitted to be
installed in fire door assemblies.

LEFT
HAND
DOOR

RIGHT
HAND
DOOR

Size of Door & Door Closer

Type

of

Installation

Interior

Exterior

In-swinging

Exterior

Out-swinging

Recommended

Closer Size

**Max.

Opening

Force

lbs/f

2 4
3 0
3 6
4 0
4 6
5 0

' "
' "
' "
' "
' "
' "

2 4
2 6
3 0
3 6
4 0
4 6

' "
' "
' "
' "
' "
' "

 2 6
 3 0
 3 6

*4 0

' "
' "
' "

' " 

 2 6
 3 0

*3 6
*4 0

' "
' "

' "
' "

 3 0
 3 6
 4 0

*4 6

' "
' "
' "

' " 

1
2
3
4
5
6

8

14
16
22
24
26

8

14
16
22
24
26

1
2
3
4
5
6

Regular &

Top Jamb

Parallel

Arm

Universal Door Closers

RHR

LHR

The door closer's power size adjustment feature may require adjustment to its 
lowest setting to comply with ADA opening force guidelines.

Regular Arm

Parallel Arm

Jamb Mount

80-9330-3000-152   

Rev. 05/12

Installation Instructions

For Non-Hold Open or “A1”
Hold Open Arm Options

See pages
2 & 3

See pages
4 & 5

See pages
6 & 7

®

ASSA ABLOY

DC3200 Series                 

Multi-Sized 1 thru 6

DC3200

DC3210

DC3220

ADA compliant closers are: DC3200, DC3210, DC3220
                              

The Americans with Disabilities Act (ADA) requires that doors having door closers
have an opening force not to exceed 5 lbf. for interior doors, 8.5 lbf exterior doors. 
Use standard templating for regular arm and parallel arm applications. Jamb
mounted applications use the template for 140° door opening to achieve the
required opening force.

**NOTE: These forces are for standard templating with bearing type hinges and do not account for pressure differentials and draft.

Summary of Contents for DC3210

Page 1: ... 16 22 24 26 1 2 3 4 5 6 Regular Top Jamb Parallel Arm Universal Door Closers RHR LHR The door closer s power size adjustment feature may require adjustment to its lowest setting to comply with ADA opening force guidelines Regular Arm Parallel Arm Jamb Mount 80 9330 3000 152 Rev 05 12 Installation Instructions For Non Hold Open or A1 Hold Open Arm Options See pages 2 3 See pages 4 5 See pages 6 7 ...

Page 2: ...on door frame wall and hinge pivot conditions permitting 2 Install Closer Bracket 3 Mount Closer Body to Closer Bracket Pin Hole End Countersunk Hole End Pins 2 Page 2 To obtain extra closing force add 3 77mm to dimensions marked This will limit degree of door opening to 110 B A 2 1 4 57 2 10 5 8 270 7 1 2 191 FRAME LINE TOP OF DOOR C L HINGE OR PIVOT ARM BRACKET 4 5 16 109 5 1 25 4 L 3 8 10 1 4 2...

Page 3: ... as shown below NON HOLD OPEN ARM ONLY HOLD OPEN ARM ONLY MAIN ARM MAIN ARM THREADED ROD ARM BRACKET 6a Preload and Adjust Arm Open door and slide arm rod into arm loop Close door swing arms so adjusting arm is 90 to frame With 7 16 wrench INSTALL and TIGHTEN SCREW SECURELY Extended Maintenance Lubricate Arm periodically shaded points with a drop or two of appropriate lubricant NOTE When lubricati...

Page 4: ...Option M54 Sex nuts furnished when ordered NOTES Check hand of door see page 1 Right Hand Application Shown Left Hand Opposite Dimensions given in inches mm Do Not Scale Drawing Closer must be installed in a true horizontal plane to ensure proper closer performance Door opening up to 180 is dependent upon door frame wall and hinge pivot conditions permitting 2 3 4 70 5 8 16 1 1 2 38 1 1 4 6 35 2 I...

Page 5: ...door and then secure screw in arm loop non hold open or elbow joint hold open MINIMUM POWER MAXIMUM POWER For Adjustments See Page 8 Page 5 Parallel Arm Application Continued LATCHING SPEED VALVE CLOSING SPEED VALVE 6 Position Arm onto Closer Using hex wrench provided turn closing speed and latching speed valves clockwise until completely closed DO NOT OVER TIGHTEN Using wrench turn under side of ...

Page 6: ... point of swing clear hinges Offset and centerhung pivots Must be single acting door 2 Install Closer Bracket to Jamb Pin Hole End Countersunk Hole End Page 6 Holding Pins 3 Mount Closer Body to Closer Bracket NOTES Check hand of door see page 1 Right Hand Application Shown Left Hand Opposite Dimensions given in inches mm Do Not Scale Drawing Closer must be installed in a true horizontal plane to ...

Page 7: ...cating a Hold Open Arm DO NOT use any lubricant on the Holding Surface components at FOR MAXIMUM POWER FOR REGULAR POWER Hinge Install with dial screw facing down DIAL SCREW FRAME STOP 5b Position Arm on Closer Main arm projects straight out at 90 angle to door Remove main arm screw from elbow joint and disassemble arm Thread the rod into the Arm Bracket as shown below 6b Preload and Adjust Arm Wh...

Page 8: ...R W 5 127mm Min Shaft Length Latching Speed Valve After closing speed has been obtained turn latching speed valve CLOCKWISE to SLOW latching or COUNTER CLOCKWISE to SPEED latching for last 2 to 5 of door travel NOTE Set combination of CLOSING and LATCHING speeds to between 3 and 7 seconds Use of door by handicapped elderly or small children may require even greater closing time Closing Speed Valve...