background image

Assure Lock for Andersen

®

 Patio and Entry Doors

Installation and Programming Instructions

This manual will walk you through all the required steps to add your 
new Yale Assure Lock for Andersen patio and entry doors.

Yale Assure Lock is not fully functional on Andersen 200 and 400 Series 
hinged patio doors. The patio door hookbolts must be manually locked before 
the Yale Assure lock can lock the patio door's deadbolt.

• Remove Existing Door Hardware

• Prepping your Door

• Install your Assure Lock

• Program your Assure Lock

• Add your Assure Lock to your smart home system or August App

Standard Phillips 

Head Screwdriver

FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE LOCK 

P/N YRM276/YRM476-INST-FUL Rev C

Scissors

1/8" 5/16" 3/8"

1/2" 3/4" Drill Bits

Tools needed:

Drill

AW 9184499 BA

Summary of Contents for Yale Assure

Page 1: ...atio doors The patio door hookbolts must be manually locked before the Yale Assure lock can lock the patio door s deadbolt Remove Existing Door Hardware Prepping your Door Install your Assure Lock Program your Assure Lock Add your Assure Lock to your smart home system or August App Standard Phillips Head Screwdriver FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE LOCK P NYRM276 ...

Page 2: ...Inside Lock 4 AA Batteries Optional Network Module Battery Cover Cylinder Magnet Block Magnet 8x8 PHM Handle Kit Mounting Plate Battery Cover Key Through Bolts Touchscreen Spacers Decorative Screw What s In The Box Door Position Sensor ...

Page 3: ...emove Existing HardwareIfAny Prepping Door Drill hole from both sides of door approximately 1 deep from one side then completely through from other side Enlarge existing top hole with 3 8 to 1 2 drill bit to accommodate cable 3 8 to 1 2 ...

Page 4: ...pplication Selecting Correct Spacer 4 4 Door Type Spacer Color Spacer A Series Outswing Only N A None A Series Inswing E Series 1 75 In and Outswing E Series 2 25 Inswing 400 Series 1 75 Inswing Black 200 Series 1 75 All E Series 2 25 Outswing Only Gray White E Series Architect Entrance Door and Folding Doors Sold Separately Provided when ordering thick door kit part number AYRM 270 TDK Look for p...

Page 5: ...nue installing lock the spacer will tightened to required position Spacer is installed between door and mounting plate gasket Do not over tighten Do not bend cables Insert one cable through hole at a time Installing Touchscreen 6 Outside of Door When touchscreen is aligned properly it will be flush on door Inside of Door ...

Page 6: ...stall mounting bracket with though bolts Ensure bracket is straight and tighten bolts x2 Through Bolts Inside of Door Inside of Door Installing Inside Mounting Plate 7 1 Place spindle into lock 2 Pull cables through mounting bracket Spindle ...

Page 7: ...bly Back of Inside Lock shown Door Position Sensor is on latch side of door when installed correctly Remove both tabs from gasket if installing optional Door Position Sensor Do not remove tabs if optional Door Position Sensor is not installed This step is optional and only needed when using Door Position Sensor ...

Page 8: ...8 P NYRM276 YRM476 INST FUL Rev C 9 Attaching Cable Assemblies Inside of Door Ensure cables are securely fastened into connector ...

Page 9: ...9 P NYRM276 YRM476 INST FUL Rev C 10 Installing Inside Lock Top of thumbturn must face away from latch x1 Decorative Screw x2 8x8 PHM Store excess cable in interior lock cavity Tighten Tighten ...

Page 10: ...10 P NYRM276 YRM476 INST FUL Rev C Inside of Door Testing Operation Ensure thumbturn moves freely ...

Page 11: ...11 P NYRM276 YRM476 INST FUL Rev C 11 Installing Handle Spindle Bushing Bottom View Push spindle to full depth into interior handle Set screw must enter v slot in spindle when securing handle ...

Page 12: ...12 P NYRM276 YRM476 INST FUL Rev C Installing Handles 12 Inside of Door Outside of Door Spindle v slot and handle set screw must face floor for proper installation ...

Page 13: ...13 P NYRM276 YRM476 INST FUL Rev C Inside of Door Testing Handle Operation ...

Page 14: ... Sensor Accessory Magnet For DOUBLE Operating OUTSWING Patio Doors Only As viewed from exterior Cylinder Magnet Cap Cylinder Magnet Inside of Door Mark magnet location across from Door Position Sensor Astragal 5 16 Drill Bit 5 16 Dia Hole 1 Deep Center of Astragal ...

Page 15: ...osition Sensor Accessory Magnet For DOUBLE Operating INSWING Patio Doors Only As viewed from exterior Inside of Door Block Magnet Cap Adhesive Liner Block Magnet Adhesive Liner Position magnet flush to edge and centered across from Door Position Sensor arrow ...

Page 16: ...ion Sensor Accessory Magnet For SINGLE Operating OUTSWING Patio Doors Only As viewed from exterior Inside of Door 1 4 Panel Stop Panel Stop 5 16 Dia Hole 1 Deep 1 4 From Panel Stop Edge 13c Mark magnet location across from Door Position Sensor 5 16 Drill Bit ...

Page 17: ...76 YRM476 INST FUL Rev C 13d Installing Door Position Sensor Accessory Magnet For SINGLE Operating INSWING Patio and Entry Doors Only 5 16 Drill Bit As viewed from exterior 5 16 Dia Hole 1 Deep At Marked Location ...

Page 18: ...18 P NYRM276 YRM476 INST FUL Rev C 14 Installing Optional Yale Smart Module Yale Smart Modules can be purchased separately ...

Page 19: ...stalling batteries Congratulations you ve installed your new smart lock Continue for Programming Instructions Touch the lock with your entire palm to wake the lock You will be guided to set up your lock by following the audio instructions on the lock Additional entry codes and further programming can be done through the Settings Menu Lock Activation ...

Page 20: ...s settings menu Low Battery Indicator Privacy Button Inside Notification Light Thumbturn for manual locking and unlocking Battery Cover Battery back up Hold a 9v battery to the terminals in case of dead lock batteries Use alkaline battery Press to enter or unlock Enter master Entry Code and press to access settings menu Lockout Mode ...

Page 21: ... the gear key Entered Enter 4 8 digit Master PIN Code Enter Master Code Press the gear key to continue Press Press Press The Master PIN Code is used to change lock settings A security best practice is to set your master code with 6 or more digits and create a separate code that is used daily to lock and unlock the door Creating Master PIN Code 1 ...

Page 22: ... Module Max user codes 25 without Press Enter Master PIN Code Menu Mode enter number press the gear key to continue Press Press Press Press Press Enter 4 8 digit Code code flashes Press Press Enter 4 8 digit Code Press To end programming Adding more User Codes 22 P NYRM276 YRM476 INST FUL Rev C ...

Page 23: ...e enter number press the gear key to continue Press Press Press Press 3 Deleting User Codes Deleting one entry code To delete one entry code you must enter the entry code you wish to delete To delete all entry codes Does not delete Master Entry Code 23 P NYRM276 YRM476 INST FUL Rev C ...

Page 24: ...While Yale has included several features to prevent lockout 9 Volt battery jumper low battery warnings it is still possible for a lockout situation to occur Because this product does not have a mechanical override a key Yale recommends to use this product in an environment where there are additional entry points into the dwelling ...

Page 25: ...deleted All programming features are reset to the original default settings see below 1 Remove the battery cover and batteries 2 Remove the interior lock to access the reset button 3 The reset button see image at right is located above the PCB cable connectors 4 Re insert 3 batteries and hold the reset button for 3 seconds 5 While still holding the reset button insert the 4th battery and hold the ...

Page 26: ...ng for entry code verification is set to Low 2 by default otherwise it can be set to High 1 or Silent 3 for quiet areas Language English Choosing English 1 Spanish 2 or French 3 becomes the default setting for the lock s voice prompts This feature is enabled by the Master Entry Code When enabled it restricts all user except Master Entry Code access When attempting to enter a code while the lock is...

Page 27: ...ed Automatic Re lock Disable 30 sec Inside Indicator Light One Touch Locking Enable Disable Enable Disable Continue Complete 60 sec 3 min 2 min DoorPositionSensor This function appears only with Door Position Sensor installed Enable Disable 1 Touch screen with back of hand or palm to activate 2 Enter 4 8 digit master PIN code followed by key Lock Response Menu mode enter number press key to contin...

Page 28: ...screen for backup power option Batteries do not have enough power Replace batteries Check the door gaps for any foreign objects between doorand frame Check that the wire harness is firmly connected to the PCB Check to see if Auto Re lock Mode is enabled Disable Auto Re lock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN codes must consist of 4 to...

Page 29: ...he door open extend and retract the bolt if it is smooth check the strike alignment c Confirm which Andersen door unit is in the home If an Andersen 200 Series or 400 Series hinged patio door the hookbolts must be manually engaged before the Yale Assure lock can lock the patio door s deadbolt Bolt does not extend or retract smoothly a Bolt and strike are misaligned see above b Check the backset of...

Page 30: ...terference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful Interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiv...