background image

Yale Real Living™

 Push Button Deadbolt

Installation and Programming Instructions

For Technical Assistance call Yale at 1-800-810-WIRE (9473)

NOTE TO INSTALLER

FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN DAMAGE TO THE PRODUCT
AND VOID THE FACTORY WARRANTY

An ASSA ABLOY Group brand

P/N AYRD210-INST-FUL Rev E

This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com.  

Click “Product Information  & Documentation” and then “Installation Instructions”.

Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com.  

Presione “Información del Producto y Documentación” y luego “Instrucciones de Instalación”.

Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com. 

Cliquez sur le “ ; Information sur le produit et Documentation” et puis “Installation Instructions”.

Summary of Contents for Yale Real Living YRD210-ZB

Page 1: ...able on our website in printed Spanish and French Go to www yalerealliving com Click Product Information Documentation and then Installation Instructions Este documento está disponible en español en nuestra página de internet Vaya a www yalerealliving com Presione Información del Producto y Documentación y luego Instrucciones de Instalación Ce document est disponible sur notre site Web dans le fra...

Page 2: ... Model s YRD210 ZW YRD210 ZB This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with th...

Page 3: ...terférence qui peut causer l opération peu désirée For the U4A YRHCPZB0 and 6982A YRHCPZB0 the following statement applies This equipment complies with FCC IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator and your body This transmitter must not be co located or operating in conjunc...

Page 4: ... Marker Outside Escutcheon Bolt Strike Plate Screw Pack Keys Included in the box COMPONENTS AND TOOLS Inside Escutcheon Inside Mounting Plate Battery Cover 4 AA Alkaline Batteries INSTALLATION Outside Escutcheon Inside Escutcheon 4 AA Alkaline Batteries 2 Through bolts Keys Battery Cover Bolt Strike Plate Network Module Optional 3 Inside Escutcheon Mounting screws 4 Bolt Strike Plate Mounting Scre...

Page 5: ... bottom of battery cover 3 Remove the inside mounting plate with gasket from the back door side of the inside escutcheon Battery Cover Inside Escutcheon C The outside escutcheon with gasket remains assembled Inside Escutcheon Mounting Plate with gasket Outside Escutcheon 1 2 3 a Ensure that gasket on Inside Mounting Plate is properly fitted Note the positioning of the gasket s five rubber nubs Fig...

Page 6: ...Figure 3B Figure 3A 2 M4 x 25 4mm 8 32 x 1 Flat Head Combination Screws 2 M4 x 25 4mm 8 32 x 1 Flat Head Combination Screws 1 2 NOTE Cable goes under bolt see Fig 3B 5 Secure both assemblies using 2 M6 x 59 5mm pan head machine screws Fig 4B making sure that outside escutcheon is vertically aligned Hand tighten until snug Do not over tighten Figure 4B Inside of Door Figure 4A Tongue Inside of Door...

Page 7: ...embling to ensure that the cable lies against the back recessed area of the inside escutcheon Use the cable hook Note label on circuit board as shown in Figures 6A 6B to prevent binding when installing the escutcheon over the mounting plate NOTE Connector should be pressed in firmly using thumbs until completely seated Proper position is indicated by arrows on PCB as in Figures 6A 6B and 6C Route ...

Page 8: ...turn and the key The movement of the bolt should be smooth and unobstructed If operation is not smooth review the previous steps to ensure proper installation Figure 9 4 AA Batteries Battery Cover Figure 8 3 Pan head screws 10 Insert four 4 AA alkaline batteries The lock responds with a series of beeps a red blue flash and a quick flash of all keypad LEDs When activating the lock for the first tim...

Page 9: ...der Click the indicated number Enter Master PIN code 4 8 digits in length Press the Star key on the keypad to Enter or Accept entry Enter User PIN Can be 4 8 digits in length Press the Pound key on the keypad to enter Menu mode User Number 1 25 RF Controlled 1 250 M U PROGRAMMING Programming Features Menus Keys Definitions 9 10 Operation 11 14 A unique Master PIN Code must be entered registered pr...

Page 10: ...is setting becomes available through the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch during Automatic Re lock duration or when Automatic Re lock is disabled Privacy Mode Button Pressing and holding the Privacy button found below thumbturn for a duration of four beeps deactivates the k...

Page 11: ...must be entered with in 20 seconds If time expires no codes are registered and the process must be re started PIN code structure Maximum number of user codes is 250 with Network Module without Network Module maximum is 25 user codes 1 Press the key to enter Master PIN Code Registration 2 Press the key followed by the key 3 Enter a unique 4 8 digit Master PIN code followed by the key Register Maste...

Page 12: ...erly installed release the reset button All features including adjustable settings see below should now be returned to factory default Upon reset Master Code Registration is the only option available and must be performed prior to any other programming of the lock See Operation in this manual for programming instructions Reset Lock to Factory Default Adjustable only when using Network Module with ...

Page 13: ...stricts Pin code access except Master Privacy mode is set by pressing and holding the privacy button found below thumbturn for a duration of four beeps This deactivates the keypad and sound and because it is set from the inside provides a secure and silent lock for the convenience of the occupant s Both features can be enabled or disabled from the Main Menu Privacy Mode vs All Code Lockout Mode ...

Page 14: ... controller it is recommended that it is programmed through the centralized user interface PC or hand held device to ensure communi cation between the lock and the controller unit The Master PIN code must be registered prior to any other programming of the lock Enable Disable Privacy Button Setting Handing the Lock Enable Disable For quiet areas select Disable 3 in Audio Mode 1 Enter the 4 8 digit...

Page 15: ... alignment Bolt does not extend or retract smoothly a Bolt and strike are misaligned see above b Check the backset of door relative to adjustments already made to bolt c Verify proper door preparation and re bore holes that are too small or misaligned d Verify keypad wire harness is routed under the bolt see Fig A e Verify bolt is installed with correct side up Fig A Keypad numerics are scrolling ...

Page 16: ...e lock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN codes will not register PIN codes must consist of 4 to 8 digits to register The same PIN code cannot be used for multiple users Registration management of PIN codes is set by the authority of the Master Code Contact the Master user User codes must be entered within 5 seconds or the process wil...

Page 17: ...eries must be removed prior to removing and or inserting the network module Remove battery cover Remove batteries Remove and or insert network module Reinstall batteries Installing the Network Module Use feature programming step 7 page 12 for enrollment of the Network Module ...

Page 18: ...r plastic guide is removed F Remove cylinder housing by pulling towards the door side of escutcheon Before installing cylinder please be sure you have correct length tailpiece 2 Install new cylinder A Reverse previous steps for removing cylinder How to Replace or Install Cylinder A B D C F E 1 3 8 to 2 thick doors L 3 1 2 88 8mm 2 to 2 1 4 thick doors L 3 3 4 95 3mm Requires addition of Thin Door ...

Page 19: ...o Network Module Up to 25 Users Location Door Number User User Name User PIN Code User Type User Name User PIN Code Master User 13 User 1 User 14 User 2 User 15 User 3 User 16 User 4 User 17 User 5 User 18 User 6 User 19 User 7 User 20 User 8 User 21 User 9 User 22 User 10 User 23 User 11 User 24 User 12 User 25 ...

Page 20: ...er ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User _...

Page 21: ...n part without express written permission of Yale Security Inc an ASSA ABLOY Group company is prohibited YALE with its unique global reach and range of products is the world s favorite lock the preferred solution for securing your home family and personal belongings ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience ...

Reviews: