background image

Model W3100G

GPRS Solutions for Serial Connections

User Manual

Updated on 2013/08/15

Tel:

+86 755

8345

3318

Fax:

+86 755

8355

5891

http://www.szatc.com

Summary of Contents for W3100G

Page 1: ...ModelW3100G GPRS Solutions for Serial Connections User Manual Updated on 2013 08 15 Tel 86 755 8345 3318 Fax 86 755 8355 5891 http www szatc com...

Page 2: ...translated into any human or computer language in any form by any means in whole or in part without the prior express written consent of SHENZHEN ATC TECHNOLOGY CO LTD Published by SHENZHEN ATC TECHNO...

Page 3: ...3 2 1 3 ACT LED 3 2 1 4 PWR LED 3 2 2 Installation Procedures 3 2 3 Power 4 3 Configuration 5 3 1 Configuration Introduction 5 3 2 Run the configure tool DTU Configuration Tool V2 3 exe 6 3 3 Configur...

Page 4: ...35 C to 80 C reaches the industrial standards This module can be used for the Industry about industrial control field communication remote monitoring intelligent power meter system traffic control me...

Page 5: ...Solutions for Serial Connections Copyright 2013 SHENZHEN ATC TECHNOLOGY CO LTD 2 2 Hardware Setup 2 1 LED Indicators 2 1 1 LINK LED Message Description Off GSM Disconnected On GSM Connected Table 1 L...

Page 6: ...Message 2 1 3 ACT LED Message Description Off No data is transmitting between GSM and serial port On Data is transmitting between GSM and serial port Table 3 ACT LED Message 2 1 4 PWR LED Message Des...

Page 7: ...d outlet Warning Forbid to install SIM card when powered Installation of antenna Screw the SMA male pin of the antenna to the female SMA outlet of the DTU tightly Warning The antenna should be screwed...

Page 8: ...S 485 cable as following 3 1 Configuration Introduction You can use a configuration software tool All the setting are configured by a software tool There should have a PC to run this tool In addition...

Page 9: ...n Tool V2 3 exe Open the configuration software Use a serial cable connect DTU to you PC and the check the COM Port number of the DTU use in the device manager Choose the correct COM port number in th...

Page 10: ...o digital outputs and every port with a relay And the output IO can output TTL signal directly The input IO can receive a high level and give an alarm signal to data center The range voltage of the hi...

Page 11: ...a the heartbeat package can know the DTU is alive Default is 120s u Interval Time of reconnect This time means how long the DTU will reconnect again Default is 30s u No Response Time This means the DT...

Page 12: ...time should wait for next transmission u APN u Center Phone It can set to mobile phone number to send and receive message u Debug Information Debug information is used to debug software when there is...

Page 13: ...a message back to the mobile phone which send the message u CFG Wake Send this command to make DTU wake up After wake up the DTU will send a message back to the mobile phone which send the message u C...

Page 14: ...Connections Copyright 2013 SHENZHEN ATC TECHNOLOGY CO LTD 11 u IO Send this message to check the status of IO port u IO 01 Low O2 High I1 High I2 High Send this message to configure IO of the DTU Thos...

Page 15: ...s Server exe and then open this software After open the software the server IP will appear for example 192 168 1 8 If your PC access to internet via a router you should make a port mapping for you PC...

Page 16: ...ondly click Start Listening button start listen A DTU server is established now click Stop Listening to close server If DTU online the information of the DTU will appear in the client list Choose a DT...

Page 17: ...receive window 2 upgrade firmware of DTU Before this operate you should copy the firmware file to the folder where this server software location and rename the file to upd bin Like following 3 click...

Page 18: ...TC TECHNOLOGY CO LTD 15 4 click this button to configure the DTU this is same to the configure software 5 this text box show the ID of the DTU 6 this text box show the net type the DTU use 7 disconnec...