Package Contents
1
Requirements
2
3-2
Hardware Review (Front View)
Hardware Installation
4
1 PE1108 / PE1208 / PE3108 / PE3208 / PE6108 / PE6208 / PE8108 / PE8208
Power Distribution Unit
1 Power Cord
1 Rack Mount Kit
1. Circuit Breaker Pushbutton
2. Power Sockets
3. Readout Section
4. Power LED
5. LAN Port and LEDs
6. Reset Switch
7. Grounding Terminal
8. Sensor Ports
9. Power Socket
• Browsers accessing the eco PDU unit must support SSL 128 bit encryption.
• For cold booting of attached computers, the computer's BIOS must support Wake on LAN or System after AC
Back.
• For Safe Shutdown:
• The computer must be running Windows (Windows 2000 or higher) or Linux.
• The Safe Shutdown program (available by download from our website or on the software CD included), must
be installed and running on the computer.
Hardware Review
3-1
Rack Mounting
The eco PDU can be mounted in a 19” (1U) rack. To rack mount the device, use the rack mounting brackets that
came with your device. The brackets can be screwed to the front or rear sides of the device, and then the unit can
slide into the front of the rack, as shown in the diagram below:
Installation
To set up your eco PDU installation, refer to the installation diagram (the numbers in the diagram correspond to the
numbered steps), and do the following:
1. Use a grounding wire to ground the eco PDU by connecting one end of the wire to its grounding terminal, and
the other end of the wire to a suitable grounded object.
Note:
Do not omit this step. Proper grounding helps to prevent damage to the unit from surges or static
electricity.
2. For each device you want to connect, use its power cable to connect from the device's AC socket to any available
outlet on the eco PDU.
3. Plug the cable that connects the eco PDU to the LAN into the eco PDU's LAN port.
4. If you are using sensors in your eco PDU installation, connect them to the sensor ports on the unit’s front panel.
Note:
Sensors are optional.
5. Connect the eco PDU's power cord to an AC power source.
Note:
We strongly advise that you do not plug the eco PDU into a multi socket extension cord, since it may not
receive enough amperage to operate correctly.
Once you have finished these installation steps, you can turn on the eco PDU and the connected devices.
Note:
We strongly recommend using cable ties and cable bars to safely and securely route the cables attached to the
front of the unit.
eco PDU PE Series PE1108/PE1208/PE3108/
PE3208/PE6108/PE6208/PE8108/PE8208
Power Distribution Unit Quick Start Guide
© Copyright 2012 ATEN
®
International Co., Ltd. www.aten.com
Altusen and the Altusen logo are trademarks of ATEN International Co., Ltd.
All rights reserved. All other trademarks are the property of their respective owners.
This product is RoHS compliant
PAPE-1215-900G Printing Date: 04/2012
All information, documentation, and specifications contained in this media are subject to change without prior notification by the manufacturer.
Please visit our website to find the most up to date version.
PE1108A / PE3108A
PE1208A / PE3208A
PE1108B / PE1108G / PE3108B / PE3108G
PE1208B / PE1208G / PE3208B / PE3208G
PE6108A / PE8108A
PE6208A / PE8208A
PE6108B / PE6108G / PE8108B / PE8108G
PE1108 / PE1208 / PE3108 / PE3208
PE6108 / PE6208 / PE8108 / PE8208
PE6208B / PE6208G / PE8208B / PE8208G
Front View
Rear View
Readout Section
5
1
4
3
2
6
1
2
3
4 5
6
1
2
3
4
5
6
1
2
3
4 5
6
1
2
3
4 5
6
1
2
3
4
5
6
1
2
3
4
5
3
SELECT
PDU
CURRENT
OUTLET
CURRENT
IP
ADDRESS
SENSOR
1
SENSOR
2
OUTLET STATUS
3
SELECT
PDU
CURRENT
OUTLET
CURRENT
IP
ADDRESS
SENSOR
1
SENSOR
2
6
1
2
3
4
5
6
1
2
3
4 5
7
9
8
1 Software CD
1 User Instructions
Online Registration
International:
• http://support.aten.com
North America:
• http://www.aten-usa.com/product_registration
Technical Phone Support
International:
• 886-2-8692-6959
China:
• 86-10-5255-0110
Japan:
• 81-3-5615-5811
Korea:
• 82-2-467-6789
North America:
• 1-888-999-ATEN Ext: 4988
United Kingdom:
• 44-8-4481-58923