background image

Rev: 9.27.18

ALWAYS use proper safety precautions:

 

Wear eye protection and use nitrile or latex gloves at all times. 

Have a fire extinguisher available in the area. Run the vehicle outside or in a well ventilated area. The 3C will 

start and stop automatically. To manually stop the 3C mid-cleaning push the Emergency Stop Switch located 

on the front panel. Before performing a cleaning with the 3C check the vehicle’s engine oil and coolant levels 

and top off if needed. If the vehicle’s engine is making any unusual noise check and repair prior to cleaning. 

Check for both pending and hard DTC’s. Always use common sense when using the 3C system.

 

FOR PROFESSIONAL USE ONLY

If you need help or have questions call ATS at (800) 572-6112 for assistance.

This technology has been under development for over 4 years. It is extremely important to follow these directions.

ATS cannot be responsible for any action taken by a shop or technician that is not stated in the following information. 

Doing any procedure that is not specifically stated by ATS is at the users own risk.  

DO NOT USE THE 3C INDUCTION CLEANER ON ANY EXOTIC ENGINES such as, but not limited to; 

Ferrari, Maserati, McLaren, Bugatti, Koenigsegg, Lamborghini, etc. Additionally Do not Clean 

BMW N63-S63 V8 Twin Turbo engines

   

Getting to know your 3C

Air Bleed 

Valve

Chemical 

Reservoir A

Chemical 

Reservoir B

Chemical 

Reservoir C

Compressed 

Air Plug

Emergency

Stop Switch

Manual

Chemical

Shut Off

Start

Clean

Button

Intake

Adapter

Hoses

Cylinder

Selection

Switch

Chemical PSI

Air PSI

Arm/Disarm

Button

Holding

Clamp

Battery

Leads

2 Amp 

fast-blow fuse

Injection Nozzle

3C Cleaning

Hose Assembly

3C Intelligent Induction Cleaner          Quick Start Guide

Patent Pending

TM

Summary of Contents for 3C Intelligent Induction Cleaner

Page 1: ...hnology has been under development for over 4 years It is extremely important to follow these directions ATS cannot be responsible for any action taken by a shop or technician that is not stated in the following information Doing any procedure that is not specifically stated by ATS is at the users own risk DO NOT USE THE 3C INDUCTION CLEANER ON ANY EXOTIC ENGINES such as but not limited to Ferrari...

Page 2: ...hecked this means the Mode 6 data is not updated therefore unusable The only correct way to check the catalytic converter is to drive the vehicle and use the data PID s for the O2 and or WRAF During our 4 years of development of the 3C cleaner hundreds of vehicles were cleaned and no spark plug was ever fouled no catalytic converter was ever damaged If the catalytic converter is bad before cleanin...

Page 3: ...er of the intake manifold that will allow for equal distribution that can be used If this sensor is a Manifold Absolute Pressure MAP sensor and there is no Mass Air Flow MAF sensor on the vehicle then removing this sensor will not allow the ECM the data needed to calculate the air weight IN THIS CASE DO NOT USE THIS SENSOR PORT NOTE THE VACUUM PORT MUST BE LOCATED BEHIND THE THROTTLE PLATE Take th...

Page 4: ...he intake port used on the engine Step 6 Attach the hose side of the Intake Adapter Hose to the injection nozzle on the end of the 3C cleaning hose assembly Do not kink the hose a straight hose is preferable Step 7 Attach the black holding clamp located at the end of the 3C cleaning hose assembly to the engine This clamp has an accelerometer on it that will monitor the running state of the engine ...

Page 5: ... need to be opened during the entire cleaning process If these are closed the chemical will not be able to properly clean the induction system There are 2 types of these valves vacuum and electric If the valve is vacuum operated pull the vacuum hose off and connect a vacuum pump so the valve can be opened If the diaphragm is blown manually move the valve to the open position and zip tie it in plac...

Page 6: ...e induction system Once this button is pushed an audible alarm will sound for 10 seconds before the chemical delivery begins automatically When the alarm frequency goes up the chemical injection is about to start After the Start Clean button is pushed you will have 10 seconds to get into the vehicle and raise the RPM to 3000 Now hold the RPM between 2500 and 3300 NOTE The RPM will drop when the ch...

Page 7: ...rgency Shut Off Switch to shut the power off to the 3C Step 17 Know your 3C If the 3C encounters an unforeseen problem during the cleaning process There are manual chemical shut off valves on the top of the reservoir bottle base There is an emergency stop switch on the front panel To drop the system pressure disconnect the compressed air hose and bleed the air pressure using the air bleed on the b...

Page 8: ...ing process Step 21 Test drive the vehicle and while in 1st gear open the throttle to a wide open throttle application This will clear any chemical that is remaining in the induction system NOTE Make sure it is safe to preform the WOT application and obey the posted speed limit during the test drive The vehicle is now ready to return to your customer Step 19 Shut the engine off and remove the 3C f...

Reviews: